在儿童和青少年群体中植入髓内钉时前臂骨的髓腔填充。

IF 1.8 Q2 ORTHOPEDICS HAND Pub Date : 2024-11-01 Epub Date: 2023-06-11 DOI:10.1177/15589447231175514
Max Hamaker, Casey M Codd, Catherine C May, Nathan N O'Hara, Joshua M Abzug
{"title":"在儿童和青少年群体中植入髓内钉时前臂骨的髓腔填充。","authors":"Max Hamaker, Casey M Codd, Catherine C May, Nathan N O'Hara, Joshua M Abzug","doi":"10.1177/15589447231175514","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In the lower extremity, studies have suggested an optimal nail diameter to medullary canal diameter (ND/MCD) ratio to minimize postoperative complications. The goal of this study was to determine whether a correlation exists between the occurrence of complications, angulation, and range of motion and the ratio of the ND/MCD in the upper extremity.</p><p><strong>Methods: </strong>A total of 85 radius and ulna fractures treated with flexible intramedullary nails had ND/MCD ratios measured. Random-effects models were developed to determine the association between complications and ND/MCD ratio, angulation and ND/MCD ratio, and range of motion and ND/MCD ratio. The results were reported for unadjusted models and adjusted models.</p><p><strong>Results: </strong>Of the 85 forearm fractures treated with intramedullary nailing, there were 3 complications. The average follow-up was 6 months. The ND/MCD ratios were categorized as <0.50, 0.50 to 0.59, and ≥0.60. There was not a significant association between the different ratios and angulation, or risk of complication. There was an association between the ND/MCD ratio ≥0.60 and decreased pronation of -1.58° (-2.77° to -0.38°) and supination of -2.68° (-4.91° to -0.46°) (<i>P</i> < .05).</p><p><strong>Conclusion: </strong>This study found that there was not an association between the nail to canal diameter ratio and postoperative angulation in forearm fractures treated with flexible intramedullary nails. When choosing a flexible nail for forearm fractures, there does not appear to be an optimal ratio; it is therefore reasonable to use the ND that passes more easily.</p>","PeriodicalId":12902,"journal":{"name":"HAND","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11536834/pdf/","citationCount":"0","resultStr":"{\"title\":\"Canal Fill of the Forearm Bones When Placing Intramedullary Nails in the Pediatric and Adolescent Populations.\",\"authors\":\"Max Hamaker, Casey M Codd, Catherine C May, Nathan N O'Hara, Joshua M Abzug\",\"doi\":\"10.1177/15589447231175514\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In the lower extremity, studies have suggested an optimal nail diameter to medullary canal diameter (ND/MCD) ratio to minimize postoperative complications. The goal of this study was to determine whether a correlation exists between the occurrence of complications, angulation, and range of motion and the ratio of the ND/MCD in the upper extremity.</p><p><strong>Methods: </strong>A total of 85 radius and ulna fractures treated with flexible intramedullary nails had ND/MCD ratios measured. Random-effects models were developed to determine the association between complications and ND/MCD ratio, angulation and ND/MCD ratio, and range of motion and ND/MCD ratio. The results were reported for unadjusted models and adjusted models.</p><p><strong>Results: </strong>Of the 85 forearm fractures treated with intramedullary nailing, there were 3 complications. The average follow-up was 6 months. The ND/MCD ratios were categorized as <0.50, 0.50 to 0.59, and ≥0.60. There was not a significant association between the different ratios and angulation, or risk of complication. There was an association between the ND/MCD ratio ≥0.60 and decreased pronation of -1.58° (-2.77° to -0.38°) and supination of -2.68° (-4.91° to -0.46°) (<i>P</i> < .05).</p><p><strong>Conclusion: </strong>This study found that there was not an association between the nail to canal diameter ratio and postoperative angulation in forearm fractures treated with flexible intramedullary nails. When choosing a flexible nail for forearm fractures, there does not appear to be an optimal ratio; it is therefore reasonable to use the ND that passes more easily.</p>\",\"PeriodicalId\":12902,\"journal\":{\"name\":\"HAND\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11536834/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HAND\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/15589447231175514\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HAND","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15589447231175514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:研究表明,在下肢,最佳的钉子直径与髓管直径(ND/MCD)比率可最大限度地减少术后并发症。本研究旨在确定上肢并发症的发生、成角和活动范围与 ND/MCD 的比率之间是否存在相关性:方法:共对 85 例使用柔性髓内钉治疗的桡骨和尺骨骨折进行了 ND/MCD 比值测量。建立随机效应模型以确定并发症与 ND/MCD 比值、成角与 ND/MCD 比值、活动范围与 ND/MCD 比值之间的关系。报告了未调整模型和调整模型的结果:结果:在使用髓内钉治疗的 85 例前臂骨折中,有 3 例并发症。平均随访时间为 6 个月。ND/MCD比率分为P<.05):本研究发现,在使用柔性髓内钉治疗前臂骨折时,钉与髓管直径比与术后成角之间并无关联。在选择治疗前臂骨折的柔性髓内钉时,似乎没有一个最佳比例;因此,使用更容易通过的髓内钉是合理的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Canal Fill of the Forearm Bones When Placing Intramedullary Nails in the Pediatric and Adolescent Populations.

Background: In the lower extremity, studies have suggested an optimal nail diameter to medullary canal diameter (ND/MCD) ratio to minimize postoperative complications. The goal of this study was to determine whether a correlation exists between the occurrence of complications, angulation, and range of motion and the ratio of the ND/MCD in the upper extremity.

Methods: A total of 85 radius and ulna fractures treated with flexible intramedullary nails had ND/MCD ratios measured. Random-effects models were developed to determine the association between complications and ND/MCD ratio, angulation and ND/MCD ratio, and range of motion and ND/MCD ratio. The results were reported for unadjusted models and adjusted models.

Results: Of the 85 forearm fractures treated with intramedullary nailing, there were 3 complications. The average follow-up was 6 months. The ND/MCD ratios were categorized as <0.50, 0.50 to 0.59, and ≥0.60. There was not a significant association between the different ratios and angulation, or risk of complication. There was an association between the ND/MCD ratio ≥0.60 and decreased pronation of -1.58° (-2.77° to -0.38°) and supination of -2.68° (-4.91° to -0.46°) (P < .05).

Conclusion: This study found that there was not an association between the nail to canal diameter ratio and postoperative angulation in forearm fractures treated with flexible intramedullary nails. When choosing a flexible nail for forearm fractures, there does not appear to be an optimal ratio; it is therefore reasonable to use the ND that passes more easily.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
HAND
HAND Medicine-Surgery
CiteScore
3.30
自引率
0.00%
发文量
209
期刊介绍: HAND is the official journal of the American Association for Hand Surgery and is a peer-reviewed journal featuring articles written by clinicians worldwide presenting current research and clinical work in the field of hand surgery. It features articles related to all aspects of hand and upper extremity surgery and the post operative care and rehabilitation of the hand.
期刊最新文献
Early and Late Intrinsic Hand Muscle Reinnervation After End-to-Side AIN to Ulnar Motor Nerve Transfer. Generic Volar Locking Plate Use in Distal Radius Fractures: A Prospective Randomized Study to Evaluate Clinical Outcomes and Cost Reduction. Infections and Patient Satisfaction in WALANT Hand Surgery in a Hospital Procedure Room. Management Options and Clinical Outcomes After Flexor Tendon Ruptures Following Volar Plating of Distal Radius Fractures. Decreased Complication Rate Using Partially Threaded Compared With Fully Threaded Compression Screws in 4 Corner Arthrodesis: A Retrospective Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1