Tobias Mantel, André Lee, Shinichi Furuya, Masanori Morise, Eckart Altenmüller, Bernhard Haslinger
{"title":"口部肌张力障碍严重程度评定量表的信度和效度。","authors":"Tobias Mantel, André Lee, Shinichi Furuya, Masanori Morise, Eckart Altenmüller, Bernhard Haslinger","doi":"10.14802/jmd.22213","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Embouchure dystonia (ED) is a task-specific movement disorder that leads to loss of fine motor control of the embouchure and tongue muscles in wind musicians. In contrast to musicians' hand dystonia, no validated severity rating for ED exists, posing a major obstacle for structured assessment in scientific and clinical settings. The aim of this study is to validate an ED severity rating scale (EDSRS) allowing for a standardized estimation of symptom severity in ED.</p><p><strong>Methods: </strong>The EDSRS was set up as a composite score of six items evaluating audio-visual disease symptoms during the performance of three standardized musical tasks (sustained notes, scales, and fourths) separately for each body side. For validation, 17 musicians with ED underwent standardized audiovisual recordings during performance. Anonymized and randomized recordings were assessed by two experts in ED (raters). Statistical analysis included metrics of consistency, reliability, and construct validity with the fluctuation of the fundamental frequency of the acoustic signal (F0) (extracted in an audio analysis of the sustained notes).</p><p><strong>Results: </strong>The EDSRS showed high internal consistency (Cronbach's α = 0.975-0.983, corrected item-total correlations r = 0.90-0.96), interrater reliability (intraclass correlation coefficient [ICC] for agreement/consistency = 0.94/0.96), intrarater reliability over time (ICC per rater = 0.93/0.87) and good precision (standard error of measurement = 2.19/2.65), and correlated significantly with F0 variability (r = 0.55-0.60, p = 0.011-0.023).</p><p><strong>Conclusion: </strong>The developed EDSRS is a valid and reliable tool for the assessment of ED severity in the hands of trained expert raters. Its easy applicability makes it suitable not only for routine clinical practice but also for scientific studies.</p>","PeriodicalId":16372,"journal":{"name":"Journal of Movement Disorders","volume":"16 2","pages":"191-195"},"PeriodicalIF":2.5000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/22/28/jmd-22213.PMC10236025.pdf","citationCount":"0","resultStr":"{\"title\":\"Reliability and Validity of the Embouchure Dystonia Severity Rating Scale.\",\"authors\":\"Tobias Mantel, André Lee, Shinichi Furuya, Masanori Morise, Eckart Altenmüller, Bernhard Haslinger\",\"doi\":\"10.14802/jmd.22213\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Embouchure dystonia (ED) is a task-specific movement disorder that leads to loss of fine motor control of the embouchure and tongue muscles in wind musicians. In contrast to musicians' hand dystonia, no validated severity rating for ED exists, posing a major obstacle for structured assessment in scientific and clinical settings. The aim of this study is to validate an ED severity rating scale (EDSRS) allowing for a standardized estimation of symptom severity in ED.</p><p><strong>Methods: </strong>The EDSRS was set up as a composite score of six items evaluating audio-visual disease symptoms during the performance of three standardized musical tasks (sustained notes, scales, and fourths) separately for each body side. For validation, 17 musicians with ED underwent standardized audiovisual recordings during performance. Anonymized and randomized recordings were assessed by two experts in ED (raters). Statistical analysis included metrics of consistency, reliability, and construct validity with the fluctuation of the fundamental frequency of the acoustic signal (F0) (extracted in an audio analysis of the sustained notes).</p><p><strong>Results: </strong>The EDSRS showed high internal consistency (Cronbach's α = 0.975-0.983, corrected item-total correlations r = 0.90-0.96), interrater reliability (intraclass correlation coefficient [ICC] for agreement/consistency = 0.94/0.96), intrarater reliability over time (ICC per rater = 0.93/0.87) and good precision (standard error of measurement = 2.19/2.65), and correlated significantly with F0 variability (r = 0.55-0.60, p = 0.011-0.023).</p><p><strong>Conclusion: </strong>The developed EDSRS is a valid and reliable tool for the assessment of ED severity in the hands of trained expert raters. Its easy applicability makes it suitable not only for routine clinical practice but also for scientific studies.</p>\",\"PeriodicalId\":16372,\"journal\":{\"name\":\"Journal of Movement Disorders\",\"volume\":\"16 2\",\"pages\":\"191-195\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/22/28/jmd-22213.PMC10236025.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Movement Disorders\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.14802/jmd.22213\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Movement Disorders","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14802/jmd.22213","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Reliability and Validity of the Embouchure Dystonia Severity Rating Scale.
Objective: Embouchure dystonia (ED) is a task-specific movement disorder that leads to loss of fine motor control of the embouchure and tongue muscles in wind musicians. In contrast to musicians' hand dystonia, no validated severity rating for ED exists, posing a major obstacle for structured assessment in scientific and clinical settings. The aim of this study is to validate an ED severity rating scale (EDSRS) allowing for a standardized estimation of symptom severity in ED.
Methods: The EDSRS was set up as a composite score of six items evaluating audio-visual disease symptoms during the performance of three standardized musical tasks (sustained notes, scales, and fourths) separately for each body side. For validation, 17 musicians with ED underwent standardized audiovisual recordings during performance. Anonymized and randomized recordings were assessed by two experts in ED (raters). Statistical analysis included metrics of consistency, reliability, and construct validity with the fluctuation of the fundamental frequency of the acoustic signal (F0) (extracted in an audio analysis of the sustained notes).
Results: The EDSRS showed high internal consistency (Cronbach's α = 0.975-0.983, corrected item-total correlations r = 0.90-0.96), interrater reliability (intraclass correlation coefficient [ICC] for agreement/consistency = 0.94/0.96), intrarater reliability over time (ICC per rater = 0.93/0.87) and good precision (standard error of measurement = 2.19/2.65), and correlated significantly with F0 variability (r = 0.55-0.60, p = 0.011-0.023).
Conclusion: The developed EDSRS is a valid and reliable tool for the assessment of ED severity in the hands of trained expert raters. Its easy applicability makes it suitable not only for routine clinical practice but also for scientific studies.