Ilse G T Baeten, Jacob P Hoogendam, Arthur J A T Braat, Bart de Keizer, Cornelis G Gerestein, Ronald P Zweemer
{"title":"早期宫颈癌机器人辅助双侧前哨淋巴结定位成功的学习曲线和影响因素:一项观察性队列研究。","authors":"Ilse G T Baeten, Jacob P Hoogendam, Arthur J A T Braat, Bart de Keizer, Cornelis G Gerestein, Ronald P Zweemer","doi":"10.1080/17434440.2023.2212157","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate whether a learning curve affects the bilateral sentinel lymph node (SLN) detection in early-stage cervical cancer.</p><p><strong>Methods: </strong>All patients with FIGO (2018) stage IA1-IB2 or IIA1 cervical cancer who had undergone robot-assisted SLN mapping performed with a combination of preoperative technetium-99m nanocolloids (including preoperative imaging) and intraoperative blue dye were retrospectively included. Risk-adjusted cumulative sum (RA-CUSUM) analysis was used to determine if a learning curve based on bilateral SLN detection existed in this cohort.</p><p><strong>Results: </strong>A total of 227 cervical cancer patients were included. In 98.2% of patients (223/227) at least one SLN was detected. The bilateral SLN detection rate was 87.2% (198/227). Except for age (OR 1.06 per year, 95%CI 1.02-1.09), no significant risk factors for non-bilateral SLN detection were found (e.g., prior conization, BMI or FIGO stage). The RA-CUSUM analysis showed no clear learning phase during the first procedures and cumulative bilateral detection rate remained at least 80% during the entire inclusion period.</p><p><strong>Conclusions: </strong>In this single-institution experience, we observed no learning curve affecting robot-assisted SLN mapping using a radiotracer and blue dye in early-stage cervical cancer patients, with stable bilateral detection rates of at least 80% when adhering to a standardized methodology.</p>","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":"20 7","pages":"589-596"},"PeriodicalIF":2.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Learning curve and factors influencing successful robot-assisted bilateral sentinel lymph node mapping in early-stage cervical cancer: an observational cohort study.\",\"authors\":\"Ilse G T Baeten, Jacob P Hoogendam, Arthur J A T Braat, Bart de Keizer, Cornelis G Gerestein, Ronald P Zweemer\",\"doi\":\"10.1080/17434440.2023.2212157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate whether a learning curve affects the bilateral sentinel lymph node (SLN) detection in early-stage cervical cancer.</p><p><strong>Methods: </strong>All patients with FIGO (2018) stage IA1-IB2 or IIA1 cervical cancer who had undergone robot-assisted SLN mapping performed with a combination of preoperative technetium-99m nanocolloids (including preoperative imaging) and intraoperative blue dye were retrospectively included. Risk-adjusted cumulative sum (RA-CUSUM) analysis was used to determine if a learning curve based on bilateral SLN detection existed in this cohort.</p><p><strong>Results: </strong>A total of 227 cervical cancer patients were included. In 98.2% of patients (223/227) at least one SLN was detected. The bilateral SLN detection rate was 87.2% (198/227). Except for age (OR 1.06 per year, 95%CI 1.02-1.09), no significant risk factors for non-bilateral SLN detection were found (e.g., prior conization, BMI or FIGO stage). The RA-CUSUM analysis showed no clear learning phase during the first procedures and cumulative bilateral detection rate remained at least 80% during the entire inclusion period.</p><p><strong>Conclusions: </strong>In this single-institution experience, we observed no learning curve affecting robot-assisted SLN mapping using a radiotracer and blue dye in early-stage cervical cancer patients, with stable bilateral detection rates of at least 80% when adhering to a standardized methodology.</p>\",\"PeriodicalId\":12330,\"journal\":{\"name\":\"Expert Review of Medical Devices\",\"volume\":\"20 7\",\"pages\":\"589-596\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert Review of Medical Devices\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2023.2212157\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Medical Devices","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2212157","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Learning curve and factors influencing successful robot-assisted bilateral sentinel lymph node mapping in early-stage cervical cancer: an observational cohort study.
Objectives: To evaluate whether a learning curve affects the bilateral sentinel lymph node (SLN) detection in early-stage cervical cancer.
Methods: All patients with FIGO (2018) stage IA1-IB2 or IIA1 cervical cancer who had undergone robot-assisted SLN mapping performed with a combination of preoperative technetium-99m nanocolloids (including preoperative imaging) and intraoperative blue dye were retrospectively included. Risk-adjusted cumulative sum (RA-CUSUM) analysis was used to determine if a learning curve based on bilateral SLN detection existed in this cohort.
Results: A total of 227 cervical cancer patients were included. In 98.2% of patients (223/227) at least one SLN was detected. The bilateral SLN detection rate was 87.2% (198/227). Except for age (OR 1.06 per year, 95%CI 1.02-1.09), no significant risk factors for non-bilateral SLN detection were found (e.g., prior conization, BMI or FIGO stage). The RA-CUSUM analysis showed no clear learning phase during the first procedures and cumulative bilateral detection rate remained at least 80% during the entire inclusion period.
Conclusions: In this single-institution experience, we observed no learning curve affecting robot-assisted SLN mapping using a radiotracer and blue dye in early-stage cervical cancer patients, with stable bilateral detection rates of at least 80% when adhering to a standardized methodology.
期刊介绍:
The journal serves the device research community by providing a comprehensive body of high-quality information from leading experts, all subject to rigorous peer review. The Expert Review format is specially structured to optimize the value of the information to reader. Comprehensive coverage by each author in a key area of research or clinical practice is augmented by the following sections:
Expert commentary - a personal view on the most effective or promising strategies
Five-year view - a clear perspective of future prospects within a realistic timescale
Key issues - an executive summary cutting to the author''s most critical points
In addition to the Review program, each issue also features Medical Device Profiles - objective assessments of specific devices in development or clinical use to help inform clinical practice. There are also Perspectives - overviews highlighting areas of current debate and controversy, together with reports from the conference scene and invited Editorials.