{"title":"后下颌短战略种植体软加载方案支持可移动双侧游离端假体:1年前瞻性队列研究结果。","authors":"Norbert Enkling, Thanuja Thanendrarajah, Ayse Mathey, Simone Janner, Martin Schimmel, Samir Abou-Ayash","doi":"10.11607/ijp.7827","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate 1-year survival and success rates of 6-mm short implants placed in mandibular molar sites with two different abutments (dome/ball) retaining existing removable partial dentures (RPDs).</p><p><strong>Materials and methods: </strong>In 19 patients, 38 implants of 6-mm length were placed bilaterally. After 4 months, each participant received the dome abutment, which 2 months later was exchanged with the ball abutment. Clinical data were recorded at abutment connection (4 months postsurgery) and at 6 and 12 months postsurgery, including probing depth, bleeding on probing, presence of plaque, and standardized radiographs. Implant success was assessed using the following criteria: presence of pain, mobility, radiographic bone loss, probing depth, and the presence of exudate. For descriptive analyses, mean and SD values were calculated. Paired sample t tests and linear regressions with a significance level of α < .05 were applied to analyze the evolution of peri-implant parameters and the influence of implant placement depth.</p><p><strong>Results: </strong>The overall mean marginal bone level alteration (DMBL) was 1.05 ± 0.69 mm. A statistically significant marginal bone loss over time was observed at the mesial and distal aspects of all implants (P < .05). The implant survival rate was 100%. No implants showed pain, exudate, mobility, or probing depth > 7 mm. Three implants were classified as having satisfactory survival due to a DMBL > 2 mm (resulting success rate: 92.1%). No influence of implant placement depth was found.</p><p><strong>Conclusion: </strong>These short-term results suggest that short implants can be used in mandibular molar sites for additional posterior support of free-end RPDs. However, in individual cases, DMBL > 2 mm may occur.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"282–292"},"PeriodicalIF":2.1000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Soft Loading Protocol of Short Strategic Implants in Posterior Mandibles Supporting Removable Bilateral Free-End Prostheses: 1-year Results of a Prospective Cohort Study.\",\"authors\":\"Norbert Enkling, Thanuja Thanendrarajah, Ayse Mathey, Simone Janner, Martin Schimmel, Samir Abou-Ayash\",\"doi\":\"10.11607/ijp.7827\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate 1-year survival and success rates of 6-mm short implants placed in mandibular molar sites with two different abutments (dome/ball) retaining existing removable partial dentures (RPDs).</p><p><strong>Materials and methods: </strong>In 19 patients, 38 implants of 6-mm length were placed bilaterally. After 4 months, each participant received the dome abutment, which 2 months later was exchanged with the ball abutment. Clinical data were recorded at abutment connection (4 months postsurgery) and at 6 and 12 months postsurgery, including probing depth, bleeding on probing, presence of plaque, and standardized radiographs. Implant success was assessed using the following criteria: presence of pain, mobility, radiographic bone loss, probing depth, and the presence of exudate. For descriptive analyses, mean and SD values were calculated. Paired sample t tests and linear regressions with a significance level of α < .05 were applied to analyze the evolution of peri-implant parameters and the influence of implant placement depth.</p><p><strong>Results: </strong>The overall mean marginal bone level alteration (DMBL) was 1.05 ± 0.69 mm. A statistically significant marginal bone loss over time was observed at the mesial and distal aspects of all implants (P < .05). The implant survival rate was 100%. No implants showed pain, exudate, mobility, or probing depth > 7 mm. Three implants were classified as having satisfactory survival due to a DMBL > 2 mm (resulting success rate: 92.1%). No influence of implant placement depth was found.</p><p><strong>Conclusion: </strong>These short-term results suggest that short implants can be used in mandibular molar sites for additional posterior support of free-end RPDs. However, in individual cases, DMBL > 2 mm may occur.</p>\",\"PeriodicalId\":50292,\"journal\":{\"name\":\"International Journal of Prosthodontics\",\"volume\":\"36 3\",\"pages\":\"282–292\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.7827\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7827","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Soft Loading Protocol of Short Strategic Implants in Posterior Mandibles Supporting Removable Bilateral Free-End Prostheses: 1-year Results of a Prospective Cohort Study.
Purpose: To evaluate 1-year survival and success rates of 6-mm short implants placed in mandibular molar sites with two different abutments (dome/ball) retaining existing removable partial dentures (RPDs).
Materials and methods: In 19 patients, 38 implants of 6-mm length were placed bilaterally. After 4 months, each participant received the dome abutment, which 2 months later was exchanged with the ball abutment. Clinical data were recorded at abutment connection (4 months postsurgery) and at 6 and 12 months postsurgery, including probing depth, bleeding on probing, presence of plaque, and standardized radiographs. Implant success was assessed using the following criteria: presence of pain, mobility, radiographic bone loss, probing depth, and the presence of exudate. For descriptive analyses, mean and SD values were calculated. Paired sample t tests and linear regressions with a significance level of α < .05 were applied to analyze the evolution of peri-implant parameters and the influence of implant placement depth.
Results: The overall mean marginal bone level alteration (DMBL) was 1.05 ± 0.69 mm. A statistically significant marginal bone loss over time was observed at the mesial and distal aspects of all implants (P < .05). The implant survival rate was 100%. No implants showed pain, exudate, mobility, or probing depth > 7 mm. Three implants were classified as having satisfactory survival due to a DMBL > 2 mm (resulting success rate: 92.1%). No influence of implant placement depth was found.
Conclusion: These short-term results suggest that short implants can be used in mandibular molar sites for additional posterior support of free-end RPDs. However, in individual cases, DMBL > 2 mm may occur.
期刊介绍:
Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP)
Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.