天然牙釉质拮抗剂对釉面整体氧化锆冠和抛光整体氧化锆冠磨损的体内比较研究。

IF 2.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Prosthodontics Pub Date : 2023-05-01 DOI:10.11607/ijp.7798
Jay Rahesh Dondani, Vikrant Pardeshi, Arti Gangurde, Almas Shaikh, Aushili Mahule, Prachi Deval
{"title":"天然牙釉质拮抗剂对釉面整体氧化锆冠和抛光整体氧化锆冠磨损的体内比较研究。","authors":"Jay Rahesh Dondani,&nbsp;Vikrant Pardeshi,&nbsp;Arti Gangurde,&nbsp;Almas Shaikh,&nbsp;Aushili Mahule,&nbsp;Prachi Deval","doi":"10.11607/ijp.7798","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To comparatively evaluate the amount of wear of natural enamel against a glazed full coverage monolithic zirconia crown and a polished monolithic zirconia crown at 6 and 12 months.</p><p><strong>Materials and methods: </strong>Thirty subjects within the age range of 18 to 35 years participated in this study. The subjects received a total of 60 single crowns, which were divided into two groups: (1) 30 glazed monolithic zirconia crowns opposed by natural enamel (group A); and (2) 30 polished monolithic zirconia crowns opposed by natural enamel (group B). Each subject received a crown from both groups, placed bilaterally in endodontically treated maxillary or mandibular first molars. An impression was made of the opposing arch at 24 hours, 6 months, and 12 months. The resulting casts were scanned with a 3D optical scanner. The recall scans were superimposed and compared to baseline scans using 3D AutoCAD software. A control group was included to compare the wear values to natural enamel against natural enamel.</p><p><strong>Results: </strong>No significant difference (P = .855) was found in enamel wear between groups A (42.80 μm) and B (42.50 μm) after 6 months of use. However, a significant difference (P < .05) in enamel wear was found between group A (81.87 μm) and group B (71.43 μm) after 12 months of use.</p><p><strong>Conclusion: </strong>Glazed monolithic zirconia crowns cause more wear to the opposing enamel than polished monolithic zirconia crowns after 12 months of clinical use.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparative Evaluation of Wear of Natural Enamel Antagonist Against Glazed Monolithic Zirconia Crowns and Polished Monolithic Zirconia Crowns: An In Vivo Study.\",\"authors\":\"Jay Rahesh Dondani,&nbsp;Vikrant Pardeshi,&nbsp;Arti Gangurde,&nbsp;Almas Shaikh,&nbsp;Aushili Mahule,&nbsp;Prachi Deval\",\"doi\":\"10.11607/ijp.7798\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To comparatively evaluate the amount of wear of natural enamel against a glazed full coverage monolithic zirconia crown and a polished monolithic zirconia crown at 6 and 12 months.</p><p><strong>Materials and methods: </strong>Thirty subjects within the age range of 18 to 35 years participated in this study. The subjects received a total of 60 single crowns, which were divided into two groups: (1) 30 glazed monolithic zirconia crowns opposed by natural enamel (group A); and (2) 30 polished monolithic zirconia crowns opposed by natural enamel (group B). Each subject received a crown from both groups, placed bilaterally in endodontically treated maxillary or mandibular first molars. An impression was made of the opposing arch at 24 hours, 6 months, and 12 months. The resulting casts were scanned with a 3D optical scanner. The recall scans were superimposed and compared to baseline scans using 3D AutoCAD software. A control group was included to compare the wear values to natural enamel against natural enamel.</p><p><strong>Results: </strong>No significant difference (P = .855) was found in enamel wear between groups A (42.80 μm) and B (42.50 μm) after 6 months of use. However, a significant difference (P < .05) in enamel wear was found between group A (81.87 μm) and group B (71.43 μm) after 12 months of use.</p><p><strong>Conclusion: </strong>Glazed monolithic zirconia crowns cause more wear to the opposing enamel than polished monolithic zirconia crowns after 12 months of clinical use.</p>\",\"PeriodicalId\":50292,\"journal\":{\"name\":\"International Journal of Prosthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.7798\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7798","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

目的:比较6个月和12个月天然牙釉质对釉面全覆盖氧化锆冠和抛光氧化锆冠的磨损程度。材料与方法:30名年龄在18 ~ 35岁之间的受试者参与本研究。受试者共获得60个单牙冠,分为两组:(1)30个釉面整体氧化锆牙冠,与天然牙釉质相对立(a组);(2) 30个抛光的整体氧化锆冠(B组)。每名受试者均获得两组的冠,放置在经根管治疗的上颌或下颌第一磨牙上。在24小时、6个月和12个月时对牙弓进行印模。用3D光学扫描仪对铸件进行扫描。使用3D AutoCAD软件将召回扫描叠加并与基线扫描进行比较。另设对照组,比较天然牙釉质与天然牙釉质的磨损值。结果:A组(42.80 μm)与B组(42.50 μm)使用6个月后牙釉质磨损无显著性差异(P = 0.855)。使用12个月后,a组牙釉质磨损度为81.87 μm, B组牙釉质磨损度为71.43 μm,差异有统计学意义(P < 0.05)。结论:在临床使用12个月后,釉面整体氧化锆冠对牙釉质的磨损大于抛光整体氧化锆冠对牙釉质的磨损。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative Evaluation of Wear of Natural Enamel Antagonist Against Glazed Monolithic Zirconia Crowns and Polished Monolithic Zirconia Crowns: An In Vivo Study.

Purpose: To comparatively evaluate the amount of wear of natural enamel against a glazed full coverage monolithic zirconia crown and a polished monolithic zirconia crown at 6 and 12 months.

Materials and methods: Thirty subjects within the age range of 18 to 35 years participated in this study. The subjects received a total of 60 single crowns, which were divided into two groups: (1) 30 glazed monolithic zirconia crowns opposed by natural enamel (group A); and (2) 30 polished monolithic zirconia crowns opposed by natural enamel (group B). Each subject received a crown from both groups, placed bilaterally in endodontically treated maxillary or mandibular first molars. An impression was made of the opposing arch at 24 hours, 6 months, and 12 months. The resulting casts were scanned with a 3D optical scanner. The recall scans were superimposed and compared to baseline scans using 3D AutoCAD software. A control group was included to compare the wear values to natural enamel against natural enamel.

Results: No significant difference (P = .855) was found in enamel wear between groups A (42.80 μm) and B (42.50 μm) after 6 months of use. However, a significant difference (P < .05) in enamel wear was found between group A (81.87 μm) and group B (71.43 μm) after 12 months of use.

Conclusion: Glazed monolithic zirconia crowns cause more wear to the opposing enamel than polished monolithic zirconia crowns after 12 months of clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Prosthodontics
International Journal of Prosthodontics 医学-牙科与口腔外科
CiteScore
3.20
自引率
4.30%
发文量
82
审稿时长
6-12 weeks
期刊介绍: Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP) Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.
期刊最新文献
A Comparison of Abutment Screw Loosening in 24-Degree Angulation-Correcting and Straight Implants: An In Vitro Study. Analysis of Topography, Flexural Strength, and Microstructure of a Lithium Disilicate Glass- Ceramic after Surface Finishing. Aging and Fracture Resistance of Screw-Retained Implant-Supported Molar Crowns Fabricated from Lithium Disilicate Containing Virgilite. Comparison Between Interocclusal Registration Using Silicone Bite Registration Material and Intraoral Scanner on Clenching Strength. Satisfaction with Labial Reinforcement of Custom-Made Mouthguards Among a Cohort of Rugby Union Players: A Randomized Crossover Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1