以用户为中心的操作界面开发过程,将机器人手套与虚拟环境相结合,以优化中风后的手部康复。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2023-01-01 DOI:10.1177/20556683231166574
C E Proulx, J Higgins, C Vincent, T Vaughan, M Hewko, D H Gagnon
{"title":"以用户为中心的操作界面开发过程,将机器人手套与虚拟环境相结合,以优化中风后的手部康复。","authors":"C E Proulx,&nbsp;J Higgins,&nbsp;C Vincent,&nbsp;T Vaughan,&nbsp;M Hewko,&nbsp;D H Gagnon","doi":"10.1177/20556683231166574","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Task-specific neurorehabilitation is crucial to optimize hand recovery shortly after a stroke, but intensive neurorehabilitation remains limited in resource-constrained healthcare systems. This has led to a growing interest in the use of robotic gloves as an adjunct intervention to intensify hand-specific neurorehabilitation. This study aims to develop and assess the usability of an operating interface supporting such a technology coupled with a virtual environment through a user-centered design approach.</p><p><strong>Methods: </strong>Fourteen participants with hand hemiparesis following a stroke were invited to don the robotic glove before browsing through the operating interface and its functionalities, and perform two mobility exercises in a virtual environment. Feedback was collected for improving technology usability. Participants completed the System Usability Scale and ABILHAND questionnaires and their recommendations were gathered and prioritized in a Pugh Matrix.</p><p><strong>Results: </strong>The System Usability Scale (SUS) score for the operating interface was excellent (M = 87.0 SD = 11.6). A total of 74 recommendations to improve the user interface, calibration process, and exercise usability were identified.</p><p><strong>Conclusion: </strong>The application of a full cycle of user-centred design approach confirms the high level of usability of the system which is perceived by end users as acceptable and useful for intensifying neurorehabilitation.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2f/31/10.1177_20556683231166574.PMC10107379.pdf","citationCount":"0","resultStr":"{\"title\":\"User-centered development process of an operating interface to couple a robotic glove with a virtual environment to optimize hand rehabilitation following a stroke.\",\"authors\":\"C E Proulx,&nbsp;J Higgins,&nbsp;C Vincent,&nbsp;T Vaughan,&nbsp;M Hewko,&nbsp;D H Gagnon\",\"doi\":\"10.1177/20556683231166574\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Task-specific neurorehabilitation is crucial to optimize hand recovery shortly after a stroke, but intensive neurorehabilitation remains limited in resource-constrained healthcare systems. This has led to a growing interest in the use of robotic gloves as an adjunct intervention to intensify hand-specific neurorehabilitation. This study aims to develop and assess the usability of an operating interface supporting such a technology coupled with a virtual environment through a user-centered design approach.</p><p><strong>Methods: </strong>Fourteen participants with hand hemiparesis following a stroke were invited to don the robotic glove before browsing through the operating interface and its functionalities, and perform two mobility exercises in a virtual environment. Feedback was collected for improving technology usability. Participants completed the System Usability Scale and ABILHAND questionnaires and their recommendations were gathered and prioritized in a Pugh Matrix.</p><p><strong>Results: </strong>The System Usability Scale (SUS) score for the operating interface was excellent (M = 87.0 SD = 11.6). A total of 74 recommendations to improve the user interface, calibration process, and exercise usability were identified.</p><p><strong>Conclusion: </strong>The application of a full cycle of user-centred design approach confirms the high level of usability of the system which is perceived by end users as acceptable and useful for intensifying neurorehabilitation.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2f/31/10.1177_20556683231166574.PMC10107379.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/20556683231166574\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20556683231166574","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

任务特异性神经康复是优化中风后手部恢复的关键,但在资源有限的卫生保健系统中,强化神经康复仍然有限。这导致了越来越多的人对使用机器人手套作为辅助干预来加强手部特定神经康复的兴趣。本研究旨在通过以用户为中心的设计方法,开发和评估支持这种技术与虚拟环境相结合的操作界面的可用性。方法:邀请14名中风后偏瘫的参与者戴上机器人手套,然后浏览操作界面及其功能,并在虚拟环境中进行两次活动练习。收集反馈以改进技术可用性。参与者完成了系统可用性量表和ABILHAND问卷调查,他们的建议被收集并在Pugh矩阵中排序。结果:系统可用性量表(SUS)对操作界面的评分为优秀(M = 87.0, SD = 11.6)。共提出了74项改进用户界面、校准过程和练习可用性的建议。结论:以用户为中心的全周期设计方法的应用证实了该系统的高水平可用性,最终用户认为该系统可接受并有助于加强神经康复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
User-centered development process of an operating interface to couple a robotic glove with a virtual environment to optimize hand rehabilitation following a stroke.

Introduction: Task-specific neurorehabilitation is crucial to optimize hand recovery shortly after a stroke, but intensive neurorehabilitation remains limited in resource-constrained healthcare systems. This has led to a growing interest in the use of robotic gloves as an adjunct intervention to intensify hand-specific neurorehabilitation. This study aims to develop and assess the usability of an operating interface supporting such a technology coupled with a virtual environment through a user-centered design approach.

Methods: Fourteen participants with hand hemiparesis following a stroke were invited to don the robotic glove before browsing through the operating interface and its functionalities, and perform two mobility exercises in a virtual environment. Feedback was collected for improving technology usability. Participants completed the System Usability Scale and ABILHAND questionnaires and their recommendations were gathered and prioritized in a Pugh Matrix.

Results: The System Usability Scale (SUS) score for the operating interface was excellent (M = 87.0 SD = 11.6). A total of 74 recommendations to improve the user interface, calibration process, and exercise usability were identified.

Conclusion: The application of a full cycle of user-centred design approach confirms the high level of usability of the system which is perceived by end users as acceptable and useful for intensifying neurorehabilitation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1