口腔显微镜辅助种植体表面去污的体外研究。

Q3 Medicine 华西口腔医学杂志 Pub Date : 2023-06-01 DOI:10.7518/hxkq.2023.2022509
Wenqi Su, Jingwen Li, Lishan Jiang, Wenjie Cui, Yang Zhao, Houxuan Li
{"title":"口腔显微镜辅助种植体表面去污的体外研究。","authors":"Wenqi Su,&nbsp;Jingwen Li,&nbsp;Lishan Jiang,&nbsp;Wenjie Cui,&nbsp;Yang Zhao,&nbsp;Houxuan Li","doi":"10.7518/hxkq.2023.2022509","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate the effect of oral microscope-assisted surface decontamination on implants <i>in vitro</i>.</p><p><strong>Methods: </strong>Twelve implants that fell off because of severe peri-implantitis were collected, and decontamination was carried out on the surfaces of implants through curetting, ultrasound, titanium brushing, and sandblasting at 1×, 8×, or 12.8× magnifications. The number and sizes of residues on the implants' surfaces after decontamination were determined, and the decontamination effect was analyzed according to the thread spacing in the different parts of the thread.</p><p><strong>Results: </strong>1) The 8× and 12.8× groups scored lower for implant surface residues than the 1× group (<i>P</i><0.000 1), and the 12.8× group scored lower than the 8× group (<i>P</i><0.001); 2) no difference in residue score was found between the wide and narrow thread pitch (<i>P</i>>0.05), and the 8× and 12.8× groups had lower scores than the 1× group (<i>P</i><0.001); 3) the lowest number of contaminants was observed at the tip of the thread, whereas the highest was observed below the thread, and the difference was significant (<i>P</i><0.001). However, the thread pitch had no effect on the number of contaminants in different areas (<i>P</i>>0.05); 4) the residue scores of the 8× and 12.8× groups were lower than those of the 1× group at the thread tip and above, sag, and below the thread of the implants (<i>P</i><0.05).</p><p><strong>Conclusions: </strong>Residues on the surfaces of contaminated implants can be effectively removed by using an oral microscope. After decontamination, the residues of pollutants were mainly concentrated below the thread of the implants, and the thread pitch of the implants had no significant effect on the residues.</p>","PeriodicalId":35800,"journal":{"name":"华西口腔医学杂志","volume":"41 3","pages":"350-355"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10317860/pdf/wcjs-41-03-350.pdf","citationCount":"0","resultStr":"{\"title\":\"<i>In vitro</i> research of oral microscope-assisted implant surface decontamination.\",\"authors\":\"Wenqi Su,&nbsp;Jingwen Li,&nbsp;Lishan Jiang,&nbsp;Wenjie Cui,&nbsp;Yang Zhao,&nbsp;Houxuan Li\",\"doi\":\"10.7518/hxkq.2023.2022509\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To investigate the effect of oral microscope-assisted surface decontamination on implants <i>in vitro</i>.</p><p><strong>Methods: </strong>Twelve implants that fell off because of severe peri-implantitis were collected, and decontamination was carried out on the surfaces of implants through curetting, ultrasound, titanium brushing, and sandblasting at 1×, 8×, or 12.8× magnifications. The number and sizes of residues on the implants' surfaces after decontamination were determined, and the decontamination effect was analyzed according to the thread spacing in the different parts of the thread.</p><p><strong>Results: </strong>1) The 8× and 12.8× groups scored lower for implant surface residues than the 1× group (<i>P</i><0.000 1), and the 12.8× group scored lower than the 8× group (<i>P</i><0.001); 2) no difference in residue score was found between the wide and narrow thread pitch (<i>P</i>>0.05), and the 8× and 12.8× groups had lower scores than the 1× group (<i>P</i><0.001); 3) the lowest number of contaminants was observed at the tip of the thread, whereas the highest was observed below the thread, and the difference was significant (<i>P</i><0.001). However, the thread pitch had no effect on the number of contaminants in different areas (<i>P</i>>0.05); 4) the residue scores of the 8× and 12.8× groups were lower than those of the 1× group at the thread tip and above, sag, and below the thread of the implants (<i>P</i><0.05).</p><p><strong>Conclusions: </strong>Residues on the surfaces of contaminated implants can be effectively removed by using an oral microscope. After decontamination, the residues of pollutants were mainly concentrated below the thread of the implants, and the thread pitch of the implants had no significant effect on the residues.</p>\",\"PeriodicalId\":35800,\"journal\":{\"name\":\"华西口腔医学杂志\",\"volume\":\"41 3\",\"pages\":\"350-355\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10317860/pdf/wcjs-41-03-350.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"华西口腔医学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.7518/hxkq.2023.2022509\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"华西口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7518/hxkq.2023.2022509","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨口腔显微镜辅助表面消毒对种植体体外修复的影响。方法:收集12例因重度种植体周围炎脱落的种植体,在1倍、8倍、12.8倍的放大倍率下,采用刮除、超声、钛刷、喷砂等方法对种植体表面进行净化。测定去污后种植体表面残留的数量和大小,并根据螺纹不同部位的螺纹间距分析去污效果。结果:1)8x、12.8 x组种植体表面残留评分低于1x组(PPP>0.05), 8x、12.8 x组低于1x组(PPP>0.05);4) 8×组和12.8×组种植体在牙线尖端及牙线上方、凹陷、下方的残留评分均低于1×组(结论:口腔显微镜可有效去除污染种植体表面残留。去污后污染物残留主要集中在种植体螺纹以下,种植体螺纹间距对残留影响不显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In vitro research of oral microscope-assisted implant surface decontamination.

Objectives: To investigate the effect of oral microscope-assisted surface decontamination on implants in vitro.

Methods: Twelve implants that fell off because of severe peri-implantitis were collected, and decontamination was carried out on the surfaces of implants through curetting, ultrasound, titanium brushing, and sandblasting at 1×, 8×, or 12.8× magnifications. The number and sizes of residues on the implants' surfaces after decontamination were determined, and the decontamination effect was analyzed according to the thread spacing in the different parts of the thread.

Results: 1) The 8× and 12.8× groups scored lower for implant surface residues than the 1× group (P<0.000 1), and the 12.8× group scored lower than the 8× group (P<0.001); 2) no difference in residue score was found between the wide and narrow thread pitch (P>0.05), and the 8× and 12.8× groups had lower scores than the 1× group (P<0.001); 3) the lowest number of contaminants was observed at the tip of the thread, whereas the highest was observed below the thread, and the difference was significant (P<0.001). However, the thread pitch had no effect on the number of contaminants in different areas (P>0.05); 4) the residue scores of the 8× and 12.8× groups were lower than those of the 1× group at the thread tip and above, sag, and below the thread of the implants (P<0.05).

Conclusions: Residues on the surfaces of contaminated implants can be effectively removed by using an oral microscope. After decontamination, the residues of pollutants were mainly concentrated below the thread of the implants, and the thread pitch of the implants had no significant effect on the residues.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
华西口腔医学杂志
华西口腔医学杂志 Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
6397
期刊介绍: West China Journal of Stomatology (WCJS, pISSN 1000-1182, eISSN 2618-0456, CN 51-1169/R), published bimonthly, is a peer-reviewed Open Access journal, hosted by Sichuan university and Ministry of Education of the People's Republic of China. WCJS was established in 1983 and indexed in Medline/Pubmed, SCOPUS, EBSCO, Chemical Abstract(CA), CNKI, WANFANG Data, etc.
期刊最新文献
Comparison of the efficacy and long-term stability of tunnel technique and coronally advanced flap in the treatment of gingival recession: a Meta-analysis. Intentional replantation for the retreatment of mandibular second molar: a case report. Simultaneous implantation and tooth preparation technology guided by 3D-printed guide. Three-dimensional reconstruction reveals the correlation between the extent of alveolar clefts and secondary nasal deformity in adults. Application of modified articular disc anchorage in treating the perforation and rupture of temporomandibular joint disc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1