Gore® Excluder® Iliac 支内膜假体髂内动脉部分使用自膨胀或球囊扩张支架移植物的疗效。

IF 1.7 2区 医学 Q3 PERIPHERAL VASCULAR DISEASE Journal of Endovascular Therapy Pub Date : 2024-12-01 Epub Date: 2023-05-06 DOI:10.1177/15266028231169177
Nicholas S Cortolillo, Andres Guerra, Eric Murphy, Andrew W Hoel, Mark K Eskandari, Tadaki M Tomita
{"title":"Gore® Excluder® Iliac 支内膜假体髂内动脉部分使用自膨胀或球囊扩张支架移植物的疗效。","authors":"Nicholas S Cortolillo, Andres Guerra, Eric Murphy, Andrew W Hoel, Mark K Eskandari, Tadaki M Tomita","doi":"10.1177/15266028231169177","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The GORE<sup>®</sup> EXCLUDER<sup>®</sup> Iliac Branch Endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, Arizona) was developed to be used in combination with a self-expanding stent graft (SESG) for the internal iliac artery (IIA) bridging stent. Balloon-expandable stent grafts (BESGs) are an alternative for the IIA, offering advantages in sizing, device tracking, precision, and lower profile delivery. We compared the performance of SESG and BESG when used as the IIA bridging stent in patients undergoing EVAR with IBE.</p><p><strong>Methods: </strong>This is a retrospective review of consecutive patients who underwent EVAR with IBE implantation at a single center from October 2016 to May 2021. Anatomic and procedural characteristics were recorded via chart review and computed tomography (CT) postprocessing software (Vitrea<sup>®</sup> v7.14). Devices were assigned to SESG vs. BESG groups based on the type of device landing into the most distal IIA segment. Analysis was performed per device to account for patients undergoing bilateral IBE. The primary endpoint was IIA patency, and secondary endpoint was IBE-related endoleak.</p><p><strong>Results: </strong>During the study period, 48 IBE devices were implanted in 41 patients (mean age 71.1 years). All IBE devices were implanted in conjunction with an infrarenal endograft. There were 24 devices in each of the self-expanding internal iliac component (SE-IIC) and balloon-expandable internal iliac component (BE-IIC) groups. The BE-IIC group had smaller diameter IIA target vessels (11.6±2.0 mm vs. 8.4±1.7 mm, p<0.001). Mean follow-up was 525 days. Loss of IIA patency occurred in 2 SESG devices (8.33%) at 73 and 180 days postprocedure, and in zero BESG devices, however, this difference was not statistically significant (p=0.16). There was 1 IBE-related endoleak requiring reintervention during the study period. A BESG device required reintervention due to Type 3 endoleak at 284 days.</p><p><strong>Conclusions: </strong>There were no significant differences in outcomes between SESG and BESG when used for the IIA bridging stent in EVAR with IBE. The BESGs were associated with using 2 IIA bridging stents and were more often deployed in smaller IIA target arteries. Retrospective study design and small sample size may limit the generalizability of our findings.</p><p><strong>Clinical impact: </strong>This series compares postoperative and midterm outcomes of self expanding stent grafts and balloon expandable stent grafts (BESG) when used as the internal iliac stent graft as part of a Gore® Excluder® Iliac Branch Endoprosthesis (IBE). With similar outcomes between the two stent-grafts, our series suggests that some of the advantages of BESG, device sizing, tracking, deployment, and profile, may be able to be leveraged without impacting the mid-term performance of the IBE.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":" ","pages":"1227-1233"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Outcomes of the Gore<sup>®</sup> Excluder<sup>®</sup> Iliac Branch Endoprosthesis Using Self Expanding or Balloon-Expandable Stent Grafts for the Internal Iliac Artery Component.\",\"authors\":\"Nicholas S Cortolillo, Andres Guerra, Eric Murphy, Andrew W Hoel, Mark K Eskandari, Tadaki M Tomita\",\"doi\":\"10.1177/15266028231169177\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The GORE<sup>®</sup> EXCLUDER<sup>®</sup> Iliac Branch Endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, Arizona) was developed to be used in combination with a self-expanding stent graft (SESG) for the internal iliac artery (IIA) bridging stent. Balloon-expandable stent grafts (BESGs) are an alternative for the IIA, offering advantages in sizing, device tracking, precision, and lower profile delivery. We compared the performance of SESG and BESG when used as the IIA bridging stent in patients undergoing EVAR with IBE.</p><p><strong>Methods: </strong>This is a retrospective review of consecutive patients who underwent EVAR with IBE implantation at a single center from October 2016 to May 2021. Anatomic and procedural characteristics were recorded via chart review and computed tomography (CT) postprocessing software (Vitrea<sup>®</sup> v7.14). Devices were assigned to SESG vs. BESG groups based on the type of device landing into the most distal IIA segment. Analysis was performed per device to account for patients undergoing bilateral IBE. The primary endpoint was IIA patency, and secondary endpoint was IBE-related endoleak.</p><p><strong>Results: </strong>During the study period, 48 IBE devices were implanted in 41 patients (mean age 71.1 years). All IBE devices were implanted in conjunction with an infrarenal endograft. There were 24 devices in each of the self-expanding internal iliac component (SE-IIC) and balloon-expandable internal iliac component (BE-IIC) groups. The BE-IIC group had smaller diameter IIA target vessels (11.6±2.0 mm vs. 8.4±1.7 mm, p<0.001). Mean follow-up was 525 days. Loss of IIA patency occurred in 2 SESG devices (8.33%) at 73 and 180 days postprocedure, and in zero BESG devices, however, this difference was not statistically significant (p=0.16). There was 1 IBE-related endoleak requiring reintervention during the study period. A BESG device required reintervention due to Type 3 endoleak at 284 days.</p><p><strong>Conclusions: </strong>There were no significant differences in outcomes between SESG and BESG when used for the IIA bridging stent in EVAR with IBE. The BESGs were associated with using 2 IIA bridging stents and were more often deployed in smaller IIA target arteries. Retrospective study design and small sample size may limit the generalizability of our findings.</p><p><strong>Clinical impact: </strong>This series compares postoperative and midterm outcomes of self expanding stent grafts and balloon expandable stent grafts (BESG) when used as the internal iliac stent graft as part of a Gore® Excluder® Iliac Branch Endoprosthesis (IBE). With similar outcomes between the two stent-grafts, our series suggests that some of the advantages of BESG, device sizing, tracking, deployment, and profile, may be able to be leveraged without impacting the mid-term performance of the IBE.</p>\",\"PeriodicalId\":50210,\"journal\":{\"name\":\"Journal of Endovascular Therapy\",\"volume\":\" \",\"pages\":\"1227-1233\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Endovascular Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15266028231169177\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028231169177","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

目的:GORE® EXCLUDER® Iliac Branch Endoprosthesis(IBE;W.L. Gore & Associates,亚利桑那州弗拉格斯塔夫)的开发目的是与自膨胀支架移植物(SESG)结合使用,用于髂内动脉(IIA)桥接支架。球囊扩张支架移植物(BESG)是髂内动脉桥接支架的替代品,在尺寸、设备跟踪、精确性和低剖面输送方面具有优势。我们比较了 SESG 和 BESG 作为 IIA 桥接支架在接受 IBE EVAR 患者中的表现:这是一项回顾性研究,研究对象是 2016 年 10 月至 2021 年 5 月期间在一个中心接受 EVAR 并植入 IBE 的连续患者。通过病历审查和计算机断层扫描(CT)后处理软件(Vitrea® v7.14)记录了解剖和手术特征。根据植入最远 IIA 节段的器械类型,将器械分配到 SESG 组和 BESG 组。为了考虑接受双侧 IBE 的患者,分析是按器械进行的。主要终点是IIA通畅率,次要终点是IBE相关内漏:研究期间,共为 41 名患者(平均年龄 71.1 岁)植入了 48 个 IBE 装置。所有 IBE 装置均与肾下腔内移植物一起植入。自膨胀髂内组件(SE-IIC)组和球囊膨胀髂内组件(BE-IIC)组各有 24 个装置。BE-IIC组的IIA靶血管直径较小(11.6±2.0 mm vs. 8.4±1.7 mm,P结论):在使用IBE的EVAR中,SESG和BESG用于IIA桥接支架的结果没有明显差异。BESG 与使用 2 个 IIA 桥接支架有关,并且更多用于较小的 IIA 靶动脉。回顾性研究设计和样本量较小可能会限制我们研究结果的推广性:该系列研究比较了作为 Gore® Excluder® Iliac Branch Endoprosthesis(IBE)一部分的髂内支架移植物时,自膨胀支架移植物和球囊可膨胀支架移植物(BESG)的术后和中期疗效。两种支架移植物的疗效相似,我们的系列研究表明,BESG 在设备尺寸、跟踪、部署和外形等方面的一些优势或许可以加以利用,而不会影响 IBE 的中期性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Outcomes of the Gore® Excluder® Iliac Branch Endoprosthesis Using Self Expanding or Balloon-Expandable Stent Grafts for the Internal Iliac Artery Component.

Objective: The GORE® EXCLUDER® Iliac Branch Endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, Arizona) was developed to be used in combination with a self-expanding stent graft (SESG) for the internal iliac artery (IIA) bridging stent. Balloon-expandable stent grafts (BESGs) are an alternative for the IIA, offering advantages in sizing, device tracking, precision, and lower profile delivery. We compared the performance of SESG and BESG when used as the IIA bridging stent in patients undergoing EVAR with IBE.

Methods: This is a retrospective review of consecutive patients who underwent EVAR with IBE implantation at a single center from October 2016 to May 2021. Anatomic and procedural characteristics were recorded via chart review and computed tomography (CT) postprocessing software (Vitrea® v7.14). Devices were assigned to SESG vs. BESG groups based on the type of device landing into the most distal IIA segment. Analysis was performed per device to account for patients undergoing bilateral IBE. The primary endpoint was IIA patency, and secondary endpoint was IBE-related endoleak.

Results: During the study period, 48 IBE devices were implanted in 41 patients (mean age 71.1 years). All IBE devices were implanted in conjunction with an infrarenal endograft. There were 24 devices in each of the self-expanding internal iliac component (SE-IIC) and balloon-expandable internal iliac component (BE-IIC) groups. The BE-IIC group had smaller diameter IIA target vessels (11.6±2.0 mm vs. 8.4±1.7 mm, p<0.001). Mean follow-up was 525 days. Loss of IIA patency occurred in 2 SESG devices (8.33%) at 73 and 180 days postprocedure, and in zero BESG devices, however, this difference was not statistically significant (p=0.16). There was 1 IBE-related endoleak requiring reintervention during the study period. A BESG device required reintervention due to Type 3 endoleak at 284 days.

Conclusions: There were no significant differences in outcomes between SESG and BESG when used for the IIA bridging stent in EVAR with IBE. The BESGs were associated with using 2 IIA bridging stents and were more often deployed in smaller IIA target arteries. Retrospective study design and small sample size may limit the generalizability of our findings.

Clinical impact: This series compares postoperative and midterm outcomes of self expanding stent grafts and balloon expandable stent grafts (BESG) when used as the internal iliac stent graft as part of a Gore® Excluder® Iliac Branch Endoprosthesis (IBE). With similar outcomes between the two stent-grafts, our series suggests that some of the advantages of BESG, device sizing, tracking, deployment, and profile, may be able to be leveraged without impacting the mid-term performance of the IBE.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.30
自引率
15.40%
发文量
203
审稿时长
6-12 weeks
期刊介绍: The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.
期刊最新文献
The Value of Different Systemic Inflammatory Response Indicators in the Long-term Prognosis of Type B Aortic Dissection Patients Undergoing Thoracic Endovascular Aortic Repair. Effect of Statins on the Prognosis After Thoracic Endovascular Aortic Repair for Patients With Acute Type B Aortic Dissection. Potential of D-Dimer as a Tool to Rule Out Sac Expansion in Patients With Persistent Type 2 Endoleaks After Endovascular Aneurysm Repair. Long-Term Outcomes and Late Complications of Thoracic Endovascular Aortic Repair Using the GORE TAG or Conformable GORE TAG. Long-term Outcomes of the AcoArt II-BTK Trial: Drug-Coated Balloon Angioplasty Compared With Uncoated Balloons for the Treatment of Infrapopliteal Artery Lesions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1