利用正常听力参与者对阈值均衡缺口噪声中指数调幅音调的听觉稳态响应诊断死区的可行性。

IF 2.6 2区 医学 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY Trends in Hearing Pub Date : 2023-01-01 DOI:10.1177/23312165231173234
Emanuele Perugia, Frederic Marmel, Karolina Kluk
{"title":"利用正常听力参与者对阈值均衡缺口噪声中指数调幅音调的听觉稳态响应诊断死区的可行性。","authors":"Emanuele Perugia, Frederic Marmel, Karolina Kluk","doi":"10.1177/23312165231173234","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to assess feasibility of using electrophysiological auditory steady-state response (ASSR) masking for detecting dead regions (DRs). Fifteen normally hearing adults were tested using behavioral and electrophysiological tasks. In the electrophysiological task, ASSRs were recorded to a 2 kHz exponentially amplitude-modulated tone (AM2) presented within a notched threshold equalizing noise (TEN) whose center frequency (CF<sub>NOTCH</sub>) varied. We hypothesized that, in the absence of DRs, ASSR amplitudes would be largest for CF<sub>NOTCH</sub> at/or near the signal frequency. In the presence of a DR at the signal frequency, the largest ASSR amplitude would occur at a frequency (<i>f<sub>max</sub></i>) far away from the signal frequency. The AM2 and the TEN were presented at 60 and 75 dB SPL, respectively. In the behavioral task, for the same maskers as above, the masker level at which an AM and a pure tone could just be distinguished, denoted AM2ML, was determined, for low (10 dB above absolute AM2 threshold) and high (60 dB SPL) signal levels. We also hypothesized that the value of <i>f<sub>max</sub></i> would be similar for both techniques. The ASSR <i>f<sub>max</sub></i> values obtained from grand average ASSR amplitudes, but not from individual amplitudes, were consistent with our hypotheses. The agreement between the behavioral <i>f<sub>max</sub></i> and ASSR <i>f<sub>max</sub></i> was poor. The within-session ASSR-amplitude repeatability was good for AM2 alone, but poor for AM2 in notched TEN. The ASSR-amplitude variability between and within participants seems to be a major roadblock to developing our approach into an effective DR detection method.</p>","PeriodicalId":48678,"journal":{"name":"Trends in Hearing","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336760/pdf/","citationCount":"0","resultStr":"{\"title\":\"Feasibility of Diagnosing Dead Regions Using Auditory Steady-State Responses to an Exponentially Amplitude Modulated Tone in Threshold Equalizing Notched Noise, Assessed Using Normal-Hearing Participants.\",\"authors\":\"Emanuele Perugia, Frederic Marmel, Karolina Kluk\",\"doi\":\"10.1177/23312165231173234\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to assess feasibility of using electrophysiological auditory steady-state response (ASSR) masking for detecting dead regions (DRs). Fifteen normally hearing adults were tested using behavioral and electrophysiological tasks. In the electrophysiological task, ASSRs were recorded to a 2 kHz exponentially amplitude-modulated tone (AM2) presented within a notched threshold equalizing noise (TEN) whose center frequency (CF<sub>NOTCH</sub>) varied. We hypothesized that, in the absence of DRs, ASSR amplitudes would be largest for CF<sub>NOTCH</sub> at/or near the signal frequency. In the presence of a DR at the signal frequency, the largest ASSR amplitude would occur at a frequency (<i>f<sub>max</sub></i>) far away from the signal frequency. The AM2 and the TEN were presented at 60 and 75 dB SPL, respectively. In the behavioral task, for the same maskers as above, the masker level at which an AM and a pure tone could just be distinguished, denoted AM2ML, was determined, for low (10 dB above absolute AM2 threshold) and high (60 dB SPL) signal levels. We also hypothesized that the value of <i>f<sub>max</sub></i> would be similar for both techniques. The ASSR <i>f<sub>max</sub></i> values obtained from grand average ASSR amplitudes, but not from individual amplitudes, were consistent with our hypotheses. The agreement between the behavioral <i>f<sub>max</sub></i> and ASSR <i>f<sub>max</sub></i> was poor. The within-session ASSR-amplitude repeatability was good for AM2 alone, but poor for AM2 in notched TEN. The ASSR-amplitude variability between and within participants seems to be a major roadblock to developing our approach into an effective DR detection method.</p>\",\"PeriodicalId\":48678,\"journal\":{\"name\":\"Trends in Hearing\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10336760/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trends in Hearing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/23312165231173234\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trends in Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/23312165231173234","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在评估使用电生理学听觉稳态反应(ASSR)掩蔽检测死区(DR)的可行性。15 名听力正常的成年人接受了行为和电生理任务测试。在电生理任务中,我们记录了在中心频率(CFNOTCH)变化的缺口阈值均衡噪声(TEN)中出现的 2 kHz 指数调幅音(AM2)的听觉稳态反应。我们假设,在没有 DR 的情况下,当 CFNOTCH 位于或接近信号频率时,ASSR 幅值最大。在信号频率存在 DR 的情况下,最大的 ASSR 振幅将出现在远离信号频率的频率(fmax)上。AM2 和 TEN 的声压级分别为 60 和 75 dB。在行为任务中,对于与上述相同的掩蔽器,我们确定了在低信号水平(比 AM2 绝对阈值高 10 dB)和高信号水平(60 dB SPL)下,AM 和纯音刚刚能被区分开的掩蔽器电平,记为 AM2ML。我们还假设两种技术的 fmax 值相似。从 ASSR 总平均振幅(而非单个振幅)获得的 ASSR fmax 值与我们的假设一致。行为最大值与 ASSR 最大值之间的一致性较差。单独使用 AM2 时,会话内 ASSR 振幅的可重复性较好,但缺口 TEN 中 AM2 的可重复性较差。参与者之间和参与者内部的 ASSR 振幅变异性似乎是将我们的方法发展成有效 DR 检测方法的主要障碍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Feasibility of Diagnosing Dead Regions Using Auditory Steady-State Responses to an Exponentially Amplitude Modulated Tone in Threshold Equalizing Notched Noise, Assessed Using Normal-Hearing Participants.

The aim of this study was to assess feasibility of using electrophysiological auditory steady-state response (ASSR) masking for detecting dead regions (DRs). Fifteen normally hearing adults were tested using behavioral and electrophysiological tasks. In the electrophysiological task, ASSRs were recorded to a 2 kHz exponentially amplitude-modulated tone (AM2) presented within a notched threshold equalizing noise (TEN) whose center frequency (CFNOTCH) varied. We hypothesized that, in the absence of DRs, ASSR amplitudes would be largest for CFNOTCH at/or near the signal frequency. In the presence of a DR at the signal frequency, the largest ASSR amplitude would occur at a frequency (fmax) far away from the signal frequency. The AM2 and the TEN were presented at 60 and 75 dB SPL, respectively. In the behavioral task, for the same maskers as above, the masker level at which an AM and a pure tone could just be distinguished, denoted AM2ML, was determined, for low (10 dB above absolute AM2 threshold) and high (60 dB SPL) signal levels. We also hypothesized that the value of fmax would be similar for both techniques. The ASSR fmax values obtained from grand average ASSR amplitudes, but not from individual amplitudes, were consistent with our hypotheses. The agreement between the behavioral fmax and ASSR fmax was poor. The within-session ASSR-amplitude repeatability was good for AM2 alone, but poor for AM2 in notched TEN. The ASSR-amplitude variability between and within participants seems to be a major roadblock to developing our approach into an effective DR detection method.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Trends in Hearing
Trends in Hearing AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGYOTORH-OTORHINOLARYNGOLOGY
CiteScore
4.50
自引率
11.10%
发文量
44
审稿时长
12 weeks
期刊介绍: Trends in Hearing is an open access journal completely dedicated to publishing original research and reviews focusing on human hearing, hearing loss, hearing aids, auditory implants, and aural rehabilitation. Under its former name, Trends in Amplification, the journal established itself as a forum for concise explorations of all areas of translational hearing research by leaders in the field. Trends in Hearing has now expanded its focus to include original research articles, with the goal of becoming the premier venue for research related to human hearing and hearing loss.
期刊最新文献
Adaptation to Noise in Spectrotemporal Modulation Detection and Word Recognition On the Feasibility of Using Behavioral Listening Effort Test Methods to Evaluate Auditory Performance in Cochlear Implant Users Focusing on Positive Listening Experiences Improves Speech Intelligibility in Experienced Hearing Aid Users (Why) Do Transparent Hearing Devices Impair Speech Perception in Collocated Noise? Remixing Preferences for Western Instrumental Classical Music of Bilateral Cochlear Implant Users
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1