Pamela S Lagali, Ushananthini Shanmugalingam, Adam N Baker, Natalie Mezey, Patrice D Smith, Stuart G Coupland, Catherine Tsilfidis
{"title":"均匀场视网膜电图对小鼠视网膜神经节细胞功能分析的评价。","authors":"Pamela S Lagali, Ushananthini Shanmugalingam, Adam N Baker, Natalie Mezey, Patrice D Smith, Stuart G Coupland, Catherine Tsilfidis","doi":"10.1007/s10633-023-09933-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The uniform field electroretinogram (UF-ERG) has been suggested as an alternative to the pattern electroretinogram (PERG) for non-invasive assessment of retinal ganglion cell (RGC) function in primates. We evaluated the validity of the UF-ERG to assess mouse RGC activity in vivo.</p><p><strong>Methods: </strong>Unilateral optic nerve crush (ONC) was performed on adult C57BL/6J mice. Contralateral eyes with uncrushed optic nerves and eyes from surgically naive mice served as experimental controls. Electrophysiological visual assessment was performed at 12 weeks post-ONC. Flash-mediated visual-evoked cortical potentials (VEPs) were measured to confirm the robustness of the ONC procedure. Full-field flash ERGs were used to interrogate photoreceptor and retinal bipolar cell function. RGC function was assessed with pattern ERGs. Summed onset and offset UF-ERG responses to alternating dark and light uniform field flash stimuli of different intensities and wavelengths were recorded from ONC and control eyes, and relative differences were compared to the PERG results. Following electrophysiological analysis, RGC loss was monitored by immunohistochemical staining of the RGC marker protein, RBPMS, in post-mortem retinal tissues.</p><p><strong>Results: </strong>ONC dramatically impacts RGC integrity and optic nerve function, demonstrated by reduced RGC counts and near complete elimination of VEPs. ONC did not affect scotopic ERG a-wave and b-wave amplitudes, while PERG amplitudes of eyes subjected to ONC were reduced by approximately 50% compared to controls. Summation of ON and OFF UF-ERG responses did not reveal statistically significant differences between ONC and control eyes, regardless of visual stimulus.</p><p><strong>Conclusions: </strong>PERG responses are markedly impaired upon ONC, while UF-ERG responses are not significantly affected by surgical trauma to RGC axons in mice. The more closely related pattern and uniform field ERGs recorded in primates suggests species-specific differences in RGC features or subpopulations corresponding to PERG and UF-ERG response generators, limiting the utility of the UF-ERG for mouse RGC functional analysis.</p>","PeriodicalId":11207,"journal":{"name":"Documenta Ophthalmologica","volume":"147 1","pages":"29-43"},"PeriodicalIF":2.6000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of the uniform field electroretinogram for mouse retinal ganglion cell functional analysis.\",\"authors\":\"Pamela S Lagali, Ushananthini Shanmugalingam, Adam N Baker, Natalie Mezey, Patrice D Smith, Stuart G Coupland, Catherine Tsilfidis\",\"doi\":\"10.1007/s10633-023-09933-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The uniform field electroretinogram (UF-ERG) has been suggested as an alternative to the pattern electroretinogram (PERG) for non-invasive assessment of retinal ganglion cell (RGC) function in primates. We evaluated the validity of the UF-ERG to assess mouse RGC activity in vivo.</p><p><strong>Methods: </strong>Unilateral optic nerve crush (ONC) was performed on adult C57BL/6J mice. Contralateral eyes with uncrushed optic nerves and eyes from surgically naive mice served as experimental controls. Electrophysiological visual assessment was performed at 12 weeks post-ONC. Flash-mediated visual-evoked cortical potentials (VEPs) were measured to confirm the robustness of the ONC procedure. Full-field flash ERGs were used to interrogate photoreceptor and retinal bipolar cell function. RGC function was assessed with pattern ERGs. Summed onset and offset UF-ERG responses to alternating dark and light uniform field flash stimuli of different intensities and wavelengths were recorded from ONC and control eyes, and relative differences were compared to the PERG results. Following electrophysiological analysis, RGC loss was monitored by immunohistochemical staining of the RGC marker protein, RBPMS, in post-mortem retinal tissues.</p><p><strong>Results: </strong>ONC dramatically impacts RGC integrity and optic nerve function, demonstrated by reduced RGC counts and near complete elimination of VEPs. ONC did not affect scotopic ERG a-wave and b-wave amplitudes, while PERG amplitudes of eyes subjected to ONC were reduced by approximately 50% compared to controls. Summation of ON and OFF UF-ERG responses did not reveal statistically significant differences between ONC and control eyes, regardless of visual stimulus.</p><p><strong>Conclusions: </strong>PERG responses are markedly impaired upon ONC, while UF-ERG responses are not significantly affected by surgical trauma to RGC axons in mice. The more closely related pattern and uniform field ERGs recorded in primates suggests species-specific differences in RGC features or subpopulations corresponding to PERG and UF-ERG response generators, limiting the utility of the UF-ERG for mouse RGC functional analysis.</p>\",\"PeriodicalId\":11207,\"journal\":{\"name\":\"Documenta Ophthalmologica\",\"volume\":\"147 1\",\"pages\":\"29-43\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Documenta Ophthalmologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10633-023-09933-y\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Documenta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10633-023-09933-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Assessment of the uniform field electroretinogram for mouse retinal ganglion cell functional analysis.
Purpose: The uniform field electroretinogram (UF-ERG) has been suggested as an alternative to the pattern electroretinogram (PERG) for non-invasive assessment of retinal ganglion cell (RGC) function in primates. We evaluated the validity of the UF-ERG to assess mouse RGC activity in vivo.
Methods: Unilateral optic nerve crush (ONC) was performed on adult C57BL/6J mice. Contralateral eyes with uncrushed optic nerves and eyes from surgically naive mice served as experimental controls. Electrophysiological visual assessment was performed at 12 weeks post-ONC. Flash-mediated visual-evoked cortical potentials (VEPs) were measured to confirm the robustness of the ONC procedure. Full-field flash ERGs were used to interrogate photoreceptor and retinal bipolar cell function. RGC function was assessed with pattern ERGs. Summed onset and offset UF-ERG responses to alternating dark and light uniform field flash stimuli of different intensities and wavelengths were recorded from ONC and control eyes, and relative differences were compared to the PERG results. Following electrophysiological analysis, RGC loss was monitored by immunohistochemical staining of the RGC marker protein, RBPMS, in post-mortem retinal tissues.
Results: ONC dramatically impacts RGC integrity and optic nerve function, demonstrated by reduced RGC counts and near complete elimination of VEPs. ONC did not affect scotopic ERG a-wave and b-wave amplitudes, while PERG amplitudes of eyes subjected to ONC were reduced by approximately 50% compared to controls. Summation of ON and OFF UF-ERG responses did not reveal statistically significant differences between ONC and control eyes, regardless of visual stimulus.
Conclusions: PERG responses are markedly impaired upon ONC, while UF-ERG responses are not significantly affected by surgical trauma to RGC axons in mice. The more closely related pattern and uniform field ERGs recorded in primates suggests species-specific differences in RGC features or subpopulations corresponding to PERG and UF-ERG response generators, limiting the utility of the UF-ERG for mouse RGC functional analysis.
期刊介绍:
Documenta Ophthalmologica is an official publication of the International Society for Clinical Electrophysiology of Vision. The purpose of the journal is to promote the understanding and application of clinical electrophysiology of vision. Documenta Ophthalmologica will publish reviews, research articles, technical notes, brief reports and case studies which inform the readers about basic and clinical sciences related to visual electrodiagnosis and means to improve diagnosis and clinical management of patients using visual electrophysiology. Studies may involve animals or humans. In either case appropriate care must be taken to follow the Declaration of Helsinki for human subject or appropriate humane standards of animal care (e.g., the ARVO standards on Animal Care and Use).