Abdurrahman Coşkun
{"title":"偏见,未完成的交响曲。","authors":"Abdurrahman Coşkun","doi":"10.11613/BM.2022.030402","DOIUrl":null,"url":null,"abstract":"<p><p>In laboratory medicine, mathematical equations are frequently used to calculate various parameters including bias, imprecision, measurement uncertainty, sigma metric (SM), creatinine clearance, LDL-cholesterol concentration, <i>etc</i>. Mathematical equations have strict limitations and cannot be used in all situations and are not open to manipulations. Recently, a paper \"Bias estimation for Sigma metric calculation: Arithmetic mean <i>versus</i> quadratic mean\" was published in Biochemia Medica. In the paper, the author criticized the approach of taking the arithmetic mean of the multiple biases to obtain a single bias and proposed a quadratic method to estimate the overall bias using external quality assurance services (EQAS) data for SM calculation. This approach does not fit the purpose and it should be noted that using the correct equation in calculations is as important as using the correct reagent in the measurement of the analytes, therefore before using an equation, its suitability should be checked and confirmed.</p>","PeriodicalId":9021,"journal":{"name":"Biochemia Medica","volume":"32 3","pages":"030402"},"PeriodicalIF":3.8000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9562803/pdf/","citationCount":"2","resultStr":"{\"title\":\"Bias, the unfinished symphony.\",\"authors\":\"Abdurrahman Coşkun\",\"doi\":\"10.11613/BM.2022.030402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In laboratory medicine, mathematical equations are frequently used to calculate various parameters including bias, imprecision, measurement uncertainty, sigma metric (SM), creatinine clearance, LDL-cholesterol concentration, <i>etc</i>. Mathematical equations have strict limitations and cannot be used in all situations and are not open to manipulations. Recently, a paper \\\"Bias estimation for Sigma metric calculation: Arithmetic mean <i>versus</i> quadratic mean\\\" was published in Biochemia Medica. In the paper, the author criticized the approach of taking the arithmetic mean of the multiple biases to obtain a single bias and proposed a quadratic method to estimate the overall bias using external quality assurance services (EQAS) data for SM calculation. This approach does not fit the purpose and it should be noted that using the correct equation in calculations is as important as using the correct reagent in the measurement of the analytes, therefore before using an equation, its suitability should be checked and confirmed.</p>\",\"PeriodicalId\":9021,\"journal\":{\"name\":\"Biochemia Medica\",\"volume\":\"32 3\",\"pages\":\"030402\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9562803/pdf/\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biochemia Medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11613/BM.2022.030402\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11613/BM.2022.030402","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 2

摘要

在检验医学中,经常使用数学方程来计算各种参数,包括偏差、不精度、测量不确定度、西格玛度量(SM)、肌酐清除率、ldl -胆固醇浓度等。数学方程有严格的限制,不能在所有情况下使用,也不能被操纵。最近,在《生物化学医学》上发表了一篇题为《Sigma度量计算的偏倚估计:算术均值与二次均值》的论文。在本文中,作者批评了取多个偏差的算术平均值来获得单个偏差的方法,并提出了一种利用外部质量保证服务(EQAS)数据来估计SM计算总体偏差的二次方法。这种方法不符合目的,应该注意的是,在计算中使用正确的方程与在分析物的测量中使用正确的试剂同样重要,因此在使用方程之前,应检查和确认其适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bias, the unfinished symphony.

In laboratory medicine, mathematical equations are frequently used to calculate various parameters including bias, imprecision, measurement uncertainty, sigma metric (SM), creatinine clearance, LDL-cholesterol concentration, etc. Mathematical equations have strict limitations and cannot be used in all situations and are not open to manipulations. Recently, a paper "Bias estimation for Sigma metric calculation: Arithmetic mean versus quadratic mean" was published in Biochemia Medica. In the paper, the author criticized the approach of taking the arithmetic mean of the multiple biases to obtain a single bias and proposed a quadratic method to estimate the overall bias using external quality assurance services (EQAS) data for SM calculation. This approach does not fit the purpose and it should be noted that using the correct equation in calculations is as important as using the correct reagent in the measurement of the analytes, therefore before using an equation, its suitability should be checked and confirmed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biochemia Medica
Biochemia Medica 医学-医学实验技术
CiteScore
5.50
自引率
3.00%
发文量
70
审稿时长
>12 weeks
期刊介绍: Biochemia Medica is the official peer-reviewed journal of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Journal provides a wide coverage of research in all aspects of clinical chemistry and laboratory medicine. Following categories fit into the scope of the Journal: general clinical chemistry, haematology and haemostasis, molecular diagnostics and endocrinology. Development, validation and verification of analytical techniques and methods applicable to clinical chemistry and laboratory medicine are welcome as well as studies dealing with laboratory organization, automation and quality control. Journal publishes on a regular basis educative preanalytical case reports (Preanalytical mysteries), articles dealing with applied biostatistics (Lessons in biostatistics) and research integrity (Research integrity corner).
期刊最新文献
Quality assurance of add-on testing in plasma samples: stability limit for 29 biochemical analytes Two cases with discrepancy in the quantitative cytological assessment of cerebrospinal fluid in neonatal samples using light microscopy in comparison with Sysmex XN-1000 Common P-glycoprotein () polymorphisms do not seem to be associated with the risk of rivaroxaban-related bleeding events: Preliminary data CLSI-based verification and establishment of reference intervals for common biochemical assays in Croatian newborns Prediction interval: A powerful statistical tool for monitoring patients and analytical systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1