基于计算机断层扫描的尺骨近端髓内螺钉固定模板。

IF 1.8 Q2 ORTHOPEDICS HAND Pub Date : 2025-03-01 Epub Date: 2023-07-17 DOI:10.1177/15589447231184894
Nitin Goyal, Dominic Coutinho, Anish Ghodadra, Mark E Baratz, Robert A Kaufmann
{"title":"基于计算机断层扫描的尺骨近端髓内螺钉固定模板。","authors":"Nitin Goyal, Dominic Coutinho, Anish Ghodadra, Mark E Baratz, Robert A Kaufmann","doi":"10.1177/15589447231184894","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Intramedullary screw fixation of the proximal ulna can be used for fixation of the ulnar component in total elbow arthroplasty. Our purpose was to use computed tomography (CT) to characterize proximal ulna anatomy with respect to intramedullary screw fixation, and then to validate this templating process by inserting intramedullary screws into 3-dimensional (3D)-printed models.</p><p><strong>Methods: </strong>Thirty elbow CT scans were reformatted in the axis of the proximal ulna. Screw placement was templated by fixing a length at 78 mm distal to the centerline of ulnohumeral rotation and measuring diameter, and then fixing the screw pitch diameter to 5.5 mm and measuring length. Three-dimensional models were printed for 5 patients, and intramedullary screws were advanced as distal as possible until endosteal fit was achieved.</p><p><strong>Results: </strong>All patients had an anatomic limit for intramedullary screw fixation, due to dorsal angulation, varus angulation, or both. At 78 mm distal to the centerline of rotation, mean screw diameter was 5.4 mm (range, 3.2-8.0). When fixing screw diameter to 5.5 mm, the mean screw length was 79.9 mm (range, 64.2-107.9). All intramedullary screws were placed in the 3D models within 3 mm of the templated length, with correlation coefficient 0.992.</p><p><strong>Conclusion: </strong>This study characterized proximal ulna anatomy in the context of intramedullary screw fixation. Templating allows surgeons to predict intramedullary screw sizing, and a broad range of screw lengths and diameters is required when attempting intramedullary screw fixation for placement of the ulnar component in uncemented total elbow arthroplasty.</p>","PeriodicalId":12902,"journal":{"name":"HAND","volume":" ","pages":"284-290"},"PeriodicalIF":1.8000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11833885/pdf/","citationCount":"0","resultStr":"{\"title\":\"Computed Tomography-Based Templating of Proximal Ulna Intramedullary Screw Fixation.\",\"authors\":\"Nitin Goyal, Dominic Coutinho, Anish Ghodadra, Mark E Baratz, Robert A Kaufmann\",\"doi\":\"10.1177/15589447231184894\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Intramedullary screw fixation of the proximal ulna can be used for fixation of the ulnar component in total elbow arthroplasty. Our purpose was to use computed tomography (CT) to characterize proximal ulna anatomy with respect to intramedullary screw fixation, and then to validate this templating process by inserting intramedullary screws into 3-dimensional (3D)-printed models.</p><p><strong>Methods: </strong>Thirty elbow CT scans were reformatted in the axis of the proximal ulna. Screw placement was templated by fixing a length at 78 mm distal to the centerline of ulnohumeral rotation and measuring diameter, and then fixing the screw pitch diameter to 5.5 mm and measuring length. Three-dimensional models were printed for 5 patients, and intramedullary screws were advanced as distal as possible until endosteal fit was achieved.</p><p><strong>Results: </strong>All patients had an anatomic limit for intramedullary screw fixation, due to dorsal angulation, varus angulation, or both. At 78 mm distal to the centerline of rotation, mean screw diameter was 5.4 mm (range, 3.2-8.0). When fixing screw diameter to 5.5 mm, the mean screw length was 79.9 mm (range, 64.2-107.9). All intramedullary screws were placed in the 3D models within 3 mm of the templated length, with correlation coefficient 0.992.</p><p><strong>Conclusion: </strong>This study characterized proximal ulna anatomy in the context of intramedullary screw fixation. Templating allows surgeons to predict intramedullary screw sizing, and a broad range of screw lengths and diameters is required when attempting intramedullary screw fixation for placement of the ulnar component in uncemented total elbow arthroplasty.</p>\",\"PeriodicalId\":12902,\"journal\":{\"name\":\"HAND\",\"volume\":\" \",\"pages\":\"284-290\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11833885/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HAND\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/15589447231184894\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/7/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HAND","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15589447231184894","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/17 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:尺骨近端髓内螺钉固定可用于全肘关节置换术中尺骨假体的固定。我们的目的是使用计算机断层扫描(CT)来描述关于髓内螺钉固定的近端尺骨解剖特征,然后通过将髓内螺钉插入三维(3D)打印模型来验证该模板过程。方法:对30例肘关节CT扫描在尺骨近端轴上进行重新格式化。将螺钉固定在距肱骨旋转中心线远端78 mm处并测量直径,然后将螺钉节距直径固定至5.5 mm并测量长度。5例患者打印三维模型,髓内螺钉尽可能远端推进,直至实现髓内吻合。结果:所有患者由于背角、内翻角或两者均存在髓内螺钉固定的解剖限制。在旋转中心线远端78 mm处,平均螺钉直径为5.4 mm(范围3.2-8.0)。当螺钉直径为5.5 mm时,平均螺钉长度为79.9 mm(范围为64.2-107.9)。所有髓内螺钉均放置在距模板长度3mm以内的三维模型中,相关系数为0.992。结论:本研究在髓内螺钉固定的背景下描述了近端尺骨解剖。模板可以让外科医生预测髓内螺钉的大小,在非骨水泥全肘关节置换术中,当尝试髓内螺钉固定放置尺骨假体时,需要广泛的螺钉长度和直径范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Computed Tomography-Based Templating of Proximal Ulna Intramedullary Screw Fixation.

Background: Intramedullary screw fixation of the proximal ulna can be used for fixation of the ulnar component in total elbow arthroplasty. Our purpose was to use computed tomography (CT) to characterize proximal ulna anatomy with respect to intramedullary screw fixation, and then to validate this templating process by inserting intramedullary screws into 3-dimensional (3D)-printed models.

Methods: Thirty elbow CT scans were reformatted in the axis of the proximal ulna. Screw placement was templated by fixing a length at 78 mm distal to the centerline of ulnohumeral rotation and measuring diameter, and then fixing the screw pitch diameter to 5.5 mm and measuring length. Three-dimensional models were printed for 5 patients, and intramedullary screws were advanced as distal as possible until endosteal fit was achieved.

Results: All patients had an anatomic limit for intramedullary screw fixation, due to dorsal angulation, varus angulation, or both. At 78 mm distal to the centerline of rotation, mean screw diameter was 5.4 mm (range, 3.2-8.0). When fixing screw diameter to 5.5 mm, the mean screw length was 79.9 mm (range, 64.2-107.9). All intramedullary screws were placed in the 3D models within 3 mm of the templated length, with correlation coefficient 0.992.

Conclusion: This study characterized proximal ulna anatomy in the context of intramedullary screw fixation. Templating allows surgeons to predict intramedullary screw sizing, and a broad range of screw lengths and diameters is required when attempting intramedullary screw fixation for placement of the ulnar component in uncemented total elbow arthroplasty.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
HAND
HAND Medicine-Surgery
CiteScore
3.30
自引率
0.00%
发文量
209
期刊介绍: HAND is the official journal of the American Association for Hand Surgery and is a peer-reviewed journal featuring articles written by clinicians worldwide presenting current research and clinical work in the field of hand surgery. It features articles related to all aspects of hand and upper extremity surgery and the post operative care and rehabilitation of the hand.
期刊最新文献
Computed Tomography-Based Templating of Proximal Ulna Intramedullary Screw Fixation. Accuracy of MRI in Assessment of High-Grade Partial Distal Biceps Tears. Outcomes of Volar Plating Distal Radius Fractures Based on Surgical Timing. Patient-Reported Outcome Measures After Endoscopic Cubital Tunnel Release With At Least 1-Year Postoperative Follow-up. Complications in Hand Surgery During Early Independent Practice: A Single Surgeon's 5-Year Experience.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1