{"title":"目前商业市场上可塑阴茎假体的现状综述。","authors":"Eric Chung, Juan Wang","doi":"10.1177/17562872231179008","DOIUrl":null,"url":null,"abstract":"<p><p>The malleable penile implant is often considered an inferior device to the three-piece inflatable penile prosthesis implant. Nonetheless, the malleable prosthesis has its unique advantages such as lower cost, easier to perform and fewer mechanical complications than inflatable prostheses. Furthermore, its role can be extended to patients with issues relating to poor manual hand dexterity, those undergoing a salvage for infection prosthesis and as an emergency surgical measure in patients presenting with acute ischaemic priapism. Over the past few decades, there have been numerous design and technological advancements to improve overall clinical efficacy, mechanical durability, axial rigidity and device concealability of malleable penile prostheses. The following article provides a narrative review of the six major contemporary malleable penile prosthesis devices in the commercial market, namely, the Coloplast Genesis prosthesis, the Boston Scientific Tactra prosthesis, the Zephyr ZSI 100 and 100 (female-to-male) FTM devices, the Rigi10 prosthesis, the TUBE malleable prosthesis and the Shah prosthesis and evaluates the published outcomes. Appropriate patient selection and strict counselling regarding what to expect with malleable prostheses coupled with adherence to safe surgical principles are paramount to ensure excellent clinical success and patient satisfaction rates.</p>","PeriodicalId":23010,"journal":{"name":"Therapeutic Advances in Urology","volume":"15 ","pages":"17562872231179008"},"PeriodicalIF":2.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350748/pdf/","citationCount":"0","resultStr":"{\"title\":\"State-of-art review of current malleable penile prosthesis devices in the commercial market.\",\"authors\":\"Eric Chung, Juan Wang\",\"doi\":\"10.1177/17562872231179008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The malleable penile implant is often considered an inferior device to the three-piece inflatable penile prosthesis implant. Nonetheless, the malleable prosthesis has its unique advantages such as lower cost, easier to perform and fewer mechanical complications than inflatable prostheses. Furthermore, its role can be extended to patients with issues relating to poor manual hand dexterity, those undergoing a salvage for infection prosthesis and as an emergency surgical measure in patients presenting with acute ischaemic priapism. Over the past few decades, there have been numerous design and technological advancements to improve overall clinical efficacy, mechanical durability, axial rigidity and device concealability of malleable penile prostheses. The following article provides a narrative review of the six major contemporary malleable penile prosthesis devices in the commercial market, namely, the Coloplast Genesis prosthesis, the Boston Scientific Tactra prosthesis, the Zephyr ZSI 100 and 100 (female-to-male) FTM devices, the Rigi10 prosthesis, the TUBE malleable prosthesis and the Shah prosthesis and evaluates the published outcomes. Appropriate patient selection and strict counselling regarding what to expect with malleable prostheses coupled with adherence to safe surgical principles are paramount to ensure excellent clinical success and patient satisfaction rates.</p>\",\"PeriodicalId\":23010,\"journal\":{\"name\":\"Therapeutic Advances in Urology\",\"volume\":\"15 \",\"pages\":\"17562872231179008\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10350748/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Advances in Urology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17562872231179008\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17562872231179008","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
State-of-art review of current malleable penile prosthesis devices in the commercial market.
The malleable penile implant is often considered an inferior device to the three-piece inflatable penile prosthesis implant. Nonetheless, the malleable prosthesis has its unique advantages such as lower cost, easier to perform and fewer mechanical complications than inflatable prostheses. Furthermore, its role can be extended to patients with issues relating to poor manual hand dexterity, those undergoing a salvage for infection prosthesis and as an emergency surgical measure in patients presenting with acute ischaemic priapism. Over the past few decades, there have been numerous design and technological advancements to improve overall clinical efficacy, mechanical durability, axial rigidity and device concealability of malleable penile prostheses. The following article provides a narrative review of the six major contemporary malleable penile prosthesis devices in the commercial market, namely, the Coloplast Genesis prosthesis, the Boston Scientific Tactra prosthesis, the Zephyr ZSI 100 and 100 (female-to-male) FTM devices, the Rigi10 prosthesis, the TUBE malleable prosthesis and the Shah prosthesis and evaluates the published outcomes. Appropriate patient selection and strict counselling regarding what to expect with malleable prostheses coupled with adherence to safe surgical principles are paramount to ensure excellent clinical success and patient satisfaction rates.
期刊介绍:
Therapeutic Advances in Urology delivers the highest quality peer-reviewed articles, reviews, and scholarly comment on pioneering efforts and innovative studies across all areas of urology.
The journal has a strong clinical and pharmacological focus and is aimed at clinicians and researchers in urology, providing a forum in print and online for publishing the highest quality articles in this area. The editors welcome articles of current interest across all areas of urology, including treatment of urological disorders, with a focus on emerging pharmacological therapies.