{"title":"臂丛神经手术中端到端神经修复后是否有可能追踪破裂风险?技术说明。","authors":"Servet Aydın Yücetürk","doi":"10.5152/j.aott.2023.22157","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In traumatic and obstetric brachial plexus injuries, removal of the damaged nerve, repair with the nerve grafts, and nerve transfers are mostly preferred techniques. Success is directly proportional to surgical technique as it is known that end-to-end repair of the peripheral nerves gives better results. The greatest risk in end-to-end repair is the nerve rupture at the brachial plexus repair region and this cannot be detected by conventional radiological techniques.</p><p><strong>Methods: </strong>Brachial plexus injuries of obstetrical and traumatic patients were operated. If possible and at least one nerve was repaired end to end, follow-up of nerve continuity was done by titanium hemopclip insertion to both sides of the nerve repair area. A new technique nerve repair site marking was developed and end-to-end nerve repair continuity was followed simply by x-ray.</p><p><strong>Results: </strong>This technique was used for end-to-end nerve coaptions of 38 obstetric and 40 traumatic brachial plexus injuries. Follow-up was done for 6 weeks. Every week patients sent the x-ray of the repair site. Only 3 patients had nerve repair site rupture, and revision surgery was done immediately.</p><p><strong>Conclusion: </strong>Nerve repair site marking technique and follow-up with only x-ray is a simple reliable, safe, and cheap method that can be applied to any end-to-end nerve repair. This technique has no morbidity or side effects. The aim of the study is to summarize or explain the nerve repair site marking technique used in the brachial plexus region.</p>","PeriodicalId":7097,"journal":{"name":"Acta orthopaedica et traumatologica turcica","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/82/63/aott-57-3-120.PMC10544592.pdf","citationCount":"0","resultStr":"{\"title\":\"Is it possible to follow the risk of rupture after end-to-end nerve repairs in brachial plexus surgery? Technical note.\",\"authors\":\"Servet Aydın Yücetürk\",\"doi\":\"10.5152/j.aott.2023.22157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>In traumatic and obstetric brachial plexus injuries, removal of the damaged nerve, repair with the nerve grafts, and nerve transfers are mostly preferred techniques. Success is directly proportional to surgical technique as it is known that end-to-end repair of the peripheral nerves gives better results. The greatest risk in end-to-end repair is the nerve rupture at the brachial plexus repair region and this cannot be detected by conventional radiological techniques.</p><p><strong>Methods: </strong>Brachial plexus injuries of obstetrical and traumatic patients were operated. If possible and at least one nerve was repaired end to end, follow-up of nerve continuity was done by titanium hemopclip insertion to both sides of the nerve repair area. A new technique nerve repair site marking was developed and end-to-end nerve repair continuity was followed simply by x-ray.</p><p><strong>Results: </strong>This technique was used for end-to-end nerve coaptions of 38 obstetric and 40 traumatic brachial plexus injuries. Follow-up was done for 6 weeks. Every week patients sent the x-ray of the repair site. Only 3 patients had nerve repair site rupture, and revision surgery was done immediately.</p><p><strong>Conclusion: </strong>Nerve repair site marking technique and follow-up with only x-ray is a simple reliable, safe, and cheap method that can be applied to any end-to-end nerve repair. This technique has no morbidity or side effects. The aim of the study is to summarize or explain the nerve repair site marking technique used in the brachial plexus region.</p>\",\"PeriodicalId\":7097,\"journal\":{\"name\":\"Acta orthopaedica et traumatologica turcica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/82/63/aott-57-3-120.PMC10544592.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta orthopaedica et traumatologica turcica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5152/j.aott.2023.22157\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica et traumatologica turcica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5152/j.aott.2023.22157","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Is it possible to follow the risk of rupture after end-to-end nerve repairs in brachial plexus surgery? Technical note.
Objective: In traumatic and obstetric brachial plexus injuries, removal of the damaged nerve, repair with the nerve grafts, and nerve transfers are mostly preferred techniques. Success is directly proportional to surgical technique as it is known that end-to-end repair of the peripheral nerves gives better results. The greatest risk in end-to-end repair is the nerve rupture at the brachial plexus repair region and this cannot be detected by conventional radiological techniques.
Methods: Brachial plexus injuries of obstetrical and traumatic patients were operated. If possible and at least one nerve was repaired end to end, follow-up of nerve continuity was done by titanium hemopclip insertion to both sides of the nerve repair area. A new technique nerve repair site marking was developed and end-to-end nerve repair continuity was followed simply by x-ray.
Results: This technique was used for end-to-end nerve coaptions of 38 obstetric and 40 traumatic brachial plexus injuries. Follow-up was done for 6 weeks. Every week patients sent the x-ray of the repair site. Only 3 patients had nerve repair site rupture, and revision surgery was done immediately.
Conclusion: Nerve repair site marking technique and follow-up with only x-ray is a simple reliable, safe, and cheap method that can be applied to any end-to-end nerve repair. This technique has no morbidity or side effects. The aim of the study is to summarize or explain the nerve repair site marking technique used in the brachial plexus region.
期刊介绍:
Acta Orthopaedica et Traumatologica Turcica (AOTT) is an international, scientific, open access periodical published in accordance with independent, unbiased, and double-blinded peer-review principles. The journal is the official publication of the Turkish Association of Orthopaedics and Traumatology, and Turkish Society of Orthopaedics and Traumatology. It is published bimonthly in January, March, May, July, September, and November. The publication language of the journal is English.
The aim of the journal is to publish original studies of the highest scientific and clinical value in orthopedics, traumatology, and related disciplines. The scope of the journal includes but not limited to diagnostic, treatment, and prevention methods related to orthopedics and traumatology. Acta Orthopaedica et Traumatologica Turcica publishes clinical and basic research articles, case reports, personal clinical and technical notes, systematic reviews and meta-analyses and letters to the Editor. Proceedings of scientific meetings are also considered for publication.