小儿心脏导管术中的实测耗氧量比假定耗氧量更准确。

IF 1.5 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pediatric Cardiology Pub Date : 2024-10-01 Epub Date: 2023-05-27 DOI:10.1007/s00246-023-03186-x
Bradford H Ralston, Andrew T Waberski, Joshua P Kanter, Jacob W Schick, Tacy E Downing
{"title":"小儿心脏导管术中的实测耗氧量比假定耗氧量更准确。","authors":"Bradford H Ralston, Andrew T Waberski, Joshua P Kanter, Jacob W Schick, Tacy E Downing","doi":"10.1007/s00246-023-03186-x","DOIUrl":null,"url":null,"abstract":"<p><p>When calculating cardiac index (C.I.) by the Fick method, oxygen consumption (VO<sub>2</sub>) is often unknown, so assumed values are typically used. This practice introduces a known source of inaccuracy into the calculation. Using a measured VO<sub>2</sub> (mVO<sub>2</sub>) from the CARESCAPE E-sCAiOVX module provides an alternative that may improve accuracy of C.I. calculations. Our aim is to validate this measurement in a general pediatric catheterization population and compare its accuracy with assumed VO<sub>2</sub> (aVO<sub>2</sub>). mVO<sub>2</sub> was recorded for all patients undergoing cardiac catheterization with general anesthesia and controlled ventilation during the study period. mVO<sub>2</sub> was compared to the reference VO<sub>2</sub> (refVO<sub>2</sub>) determined by the reverse Fick method using cardiac MRI (cMRI) or thermodilution (TD) as a reference standard for measurement of C.I. when available. 193 VO<sub>2</sub> measurements were obtained, including 71 with a corresponding cMRI or TD measure of cardiac index for validation. mVO<sub>2</sub> demonstrated satisfactory concordance and correlation with the TD- or cMRI-derived refVO<sub>2</sub> (ρ<sub>c</sub> = 0.73, r<sup>2</sup> = 0.63) with a mean bias of - 3.2% (SD ± 17.3%). Assumed VO<sub>2</sub> demonstrated much weaker concordance and correlation with refVO<sub>2</sub> (ρ<sub>c</sub> = 0.28, r<sup>2</sup> = 0.31) with a mean bias of + 27.5% (SD ± 30.0%). Subgroup analysis of patients < 36 months of age demonstrated that error in mVO<sub>2</sub> was not significantly different from that observed in older patients. Many previously reported prediction models for assuming VO<sub>2</sub> performed poorly in this younger age range. Measured oxygen consumption using the E-sCAiOVX module is significantly more accurate than assumed VO<sub>2</sub> when compared to TD- or cMRI-derived VO<sub>2</sub> in a pediatric catheterization lab.</p>","PeriodicalId":19814,"journal":{"name":"Pediatric Cardiology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measured Oxygen Consumption During Pediatric Cardiac Catheterization is More Accurate than Assumed Oxygen Consumption.\",\"authors\":\"Bradford H Ralston, Andrew T Waberski, Joshua P Kanter, Jacob W Schick, Tacy E Downing\",\"doi\":\"10.1007/s00246-023-03186-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>When calculating cardiac index (C.I.) by the Fick method, oxygen consumption (VO<sub>2</sub>) is often unknown, so assumed values are typically used. This practice introduces a known source of inaccuracy into the calculation. Using a measured VO<sub>2</sub> (mVO<sub>2</sub>) from the CARESCAPE E-sCAiOVX module provides an alternative that may improve accuracy of C.I. calculations. Our aim is to validate this measurement in a general pediatric catheterization population and compare its accuracy with assumed VO<sub>2</sub> (aVO<sub>2</sub>). mVO<sub>2</sub> was recorded for all patients undergoing cardiac catheterization with general anesthesia and controlled ventilation during the study period. mVO<sub>2</sub> was compared to the reference VO<sub>2</sub> (refVO<sub>2</sub>) determined by the reverse Fick method using cardiac MRI (cMRI) or thermodilution (TD) as a reference standard for measurement of C.I. when available. 193 VO<sub>2</sub> measurements were obtained, including 71 with a corresponding cMRI or TD measure of cardiac index for validation. mVO<sub>2</sub> demonstrated satisfactory concordance and correlation with the TD- or cMRI-derived refVO<sub>2</sub> (ρ<sub>c</sub> = 0.73, r<sup>2</sup> = 0.63) with a mean bias of - 3.2% (SD ± 17.3%). Assumed VO<sub>2</sub> demonstrated much weaker concordance and correlation with refVO<sub>2</sub> (ρ<sub>c</sub> = 0.28, r<sup>2</sup> = 0.31) with a mean bias of + 27.5% (SD ± 30.0%). Subgroup analysis of patients < 36 months of age demonstrated that error in mVO<sub>2</sub> was not significantly different from that observed in older patients. Many previously reported prediction models for assuming VO<sub>2</sub> performed poorly in this younger age range. Measured oxygen consumption using the E-sCAiOVX module is significantly more accurate than assumed VO<sub>2</sub> when compared to TD- or cMRI-derived VO<sub>2</sub> in a pediatric catheterization lab.</p>\",\"PeriodicalId\":19814,\"journal\":{\"name\":\"Pediatric Cardiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Cardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00246-023-03186-x\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00246-023-03186-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

用菲克法计算心脏指数(C.I.)时,耗氧量(VO2)往往是未知数,因此通常使用假定值。这种做法给计算带来了已知的不准确性。使用 CARESCAPE E-sCAiOVX 模块测量的 VO2 (mVO2) 可以提高 C.I. 计算的准确性。我们的目的是在普通儿科导管插入术人群中验证这种测量方法,并将其准确性与假定 VO2 (aVO2) 进行比较。在研究期间,对所有接受全身麻醉和控制通气的心导管插入术患者的 mVO2 进行了记录。mVO2 与 TD 或 cMRI 导出的 refVO2 的一致性和相关性令人满意(ρc = 0.73,r2 = 0.63),平均偏差为 -3.2%(SD ± 17.3%)。假定 VO2 与 refVO2 的一致性和相关性更弱(ρc = 0.28,r2 = 0.31),平均偏差为 + 27.5%(标度 ± 30.0%)。对患者 2 的分组分析结果与老年患者观察到的结果无明显差异。之前报道的许多假定 VO2 预测模型在这一年龄段的患者中表现不佳。在儿科导管室中,使用 E-sCAiOVX 模块测量的耗氧量与 TD 或 cMRI 导出的 VO2 相比,准确度明显高于假定的 VO2。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measured Oxygen Consumption During Pediatric Cardiac Catheterization is More Accurate than Assumed Oxygen Consumption.

When calculating cardiac index (C.I.) by the Fick method, oxygen consumption (VO2) is often unknown, so assumed values are typically used. This practice introduces a known source of inaccuracy into the calculation. Using a measured VO2 (mVO2) from the CARESCAPE E-sCAiOVX module provides an alternative that may improve accuracy of C.I. calculations. Our aim is to validate this measurement in a general pediatric catheterization population and compare its accuracy with assumed VO2 (aVO2). mVO2 was recorded for all patients undergoing cardiac catheterization with general anesthesia and controlled ventilation during the study period. mVO2 was compared to the reference VO2 (refVO2) determined by the reverse Fick method using cardiac MRI (cMRI) or thermodilution (TD) as a reference standard for measurement of C.I. when available. 193 VO2 measurements were obtained, including 71 with a corresponding cMRI or TD measure of cardiac index for validation. mVO2 demonstrated satisfactory concordance and correlation with the TD- or cMRI-derived refVO2c = 0.73, r2 = 0.63) with a mean bias of - 3.2% (SD ± 17.3%). Assumed VO2 demonstrated much weaker concordance and correlation with refVO2c = 0.28, r2 = 0.31) with a mean bias of + 27.5% (SD ± 30.0%). Subgroup analysis of patients < 36 months of age demonstrated that error in mVO2 was not significantly different from that observed in older patients. Many previously reported prediction models for assuming VO2 performed poorly in this younger age range. Measured oxygen consumption using the E-sCAiOVX module is significantly more accurate than assumed VO2 when compared to TD- or cMRI-derived VO2 in a pediatric catheterization lab.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pediatric Cardiology
Pediatric Cardiology 医学-小儿科
CiteScore
3.30
自引率
6.20%
发文量
258
审稿时长
12 months
期刊介绍: The editor of Pediatric Cardiology welcomes original manuscripts concerning all aspects of heart disease in infants, children, and adolescents, including embryology and anatomy, physiology and pharmacology, biochemistry, pathology, genetics, radiology, clinical aspects, investigative cardiology, electrophysiology and echocardiography, and cardiac surgery. Articles which may include original articles, review articles, letters to the editor etc., must be written in English and must be submitted solely to Pediatric Cardiology.
期刊最新文献
Comparison of Four-Dimensional Flow MRI, Two-Dimensional Phase-Contrast MRI and Echocardiography in Transposition of the Great Arteries. A Challenging Interventional Procedure: Transcatheter Closure of Tubular Patent Ductus Arteriosus in Patients with Pulmonary Hypertension. Impact of Residual Lesion Severity on Neurodevelopmental Outcomes Following Congenital Heart Surgery in Infancy and Childhood. Risk Stratification in Pediatric Wolff-Parkinson-White: Practice Variation Among Pediatric Cardiologists and Electrophysiologists. Outcomes of Infant Supraventricular Tachycardia Management Without Medication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1