Mina Iskander MD , Yasser Jamil MD , John K. Forrest MD , Mahesh V. Madhavan MD, MS , Raj Makkar MD , Martin B. Leon MD , Alexandra Lansky MD , Yousif Ahmad MD, PhD
{"title":"经导管主动脉瓣置换术中的脑栓塞保护","authors":"Mina Iskander MD , Yasser Jamil MD , John K. Forrest MD , Mahesh V. Madhavan MD, MS , Raj Makkar MD , Martin B. Leon MD , Alexandra Lansky MD , Yousif Ahmad MD, PhD","doi":"10.1016/j.shj.2023.100169","DOIUrl":null,"url":null,"abstract":"<div><p>Transcatheter aortic valve replacement (TAVR) is a treatment option for patients with symptomatic severe aortic stenosis across the entire spectrum of surgical risk. Recent trial data have led to the expansion of TAVR into lower-risk patients. With iterative technological advances and successive increases in procedural experience, the occurrence of complications following TAVR has declined. One of the most feared complications remains stroke, and patients consider stroke a worse outcome than death. There has therefore been great interest in strategies to mitigate the risk of stroke in patients undergoing TAVR. In this paper, we will discuss mechanisms and predictors of stroke after TAVR and describe the currently available cerebral embolic protection devices, including their design and relevant clinical studies pertaining to their use. We will also review the current overall evidence base for cerebral embolic protection during TAVR and ongoing randomized controlled trials. Finally, we will discuss our pragmatic recommendations for the use of cerebral embolic protection devices in patients undergoing TAVR.</p></div>","PeriodicalId":36053,"journal":{"name":"Structural Heart","volume":"7 4","pages":"Article 100169"},"PeriodicalIF":1.4000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10382985/pdf/","citationCount":"20","resultStr":"{\"title\":\"Cerebral Embolic Protection in Transcatheter Aortic Valve Replacement\",\"authors\":\"Mina Iskander MD , Yasser Jamil MD , John K. Forrest MD , Mahesh V. Madhavan MD, MS , Raj Makkar MD , Martin B. Leon MD , Alexandra Lansky MD , Yousif Ahmad MD, PhD\",\"doi\":\"10.1016/j.shj.2023.100169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Transcatheter aortic valve replacement (TAVR) is a treatment option for patients with symptomatic severe aortic stenosis across the entire spectrum of surgical risk. Recent trial data have led to the expansion of TAVR into lower-risk patients. With iterative technological advances and successive increases in procedural experience, the occurrence of complications following TAVR has declined. One of the most feared complications remains stroke, and patients consider stroke a worse outcome than death. There has therefore been great interest in strategies to mitigate the risk of stroke in patients undergoing TAVR. In this paper, we will discuss mechanisms and predictors of stroke after TAVR and describe the currently available cerebral embolic protection devices, including their design and relevant clinical studies pertaining to their use. We will also review the current overall evidence base for cerebral embolic protection during TAVR and ongoing randomized controlled trials. Finally, we will discuss our pragmatic recommendations for the use of cerebral embolic protection devices in patients undergoing TAVR.</p></div>\",\"PeriodicalId\":36053,\"journal\":{\"name\":\"Structural Heart\",\"volume\":\"7 4\",\"pages\":\"Article 100169\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10382985/pdf/\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Heart\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2474870623000167\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Heart","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2474870623000167","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Cerebral Embolic Protection in Transcatheter Aortic Valve Replacement
Transcatheter aortic valve replacement (TAVR) is a treatment option for patients with symptomatic severe aortic stenosis across the entire spectrum of surgical risk. Recent trial data have led to the expansion of TAVR into lower-risk patients. With iterative technological advances and successive increases in procedural experience, the occurrence of complications following TAVR has declined. One of the most feared complications remains stroke, and patients consider stroke a worse outcome than death. There has therefore been great interest in strategies to mitigate the risk of stroke in patients undergoing TAVR. In this paper, we will discuss mechanisms and predictors of stroke after TAVR and describe the currently available cerebral embolic protection devices, including their design and relevant clinical studies pertaining to their use. We will also review the current overall evidence base for cerebral embolic protection during TAVR and ongoing randomized controlled trials. Finally, we will discuss our pragmatic recommendations for the use of cerebral embolic protection devices in patients undergoing TAVR.