前交通动脉瘤轮廓装置栓塞失败后的显微外科夹闭手术:技术说明。

IF 0.9 4区 医学 Q4 CLINICAL NEUROLOGY Journal of neurological surgery. Part A, Central European neurosurgery Pub Date : 2024-05-01 Epub Date: 2023-05-31 DOI:10.1055/a-2103-7639
Christoph J Griessenauer, Monika Killer-Oberpfalzer, Carlos M Beredjiklian, Manuel Lunzer
{"title":"前交通动脉瘤轮廓装置栓塞失败后的显微外科夹闭手术:技术说明。","authors":"Christoph J Griessenauer, Monika Killer-Oberpfalzer, Carlos M Beredjiklian, Manuel Lunzer","doi":"10.1055/a-2103-7639","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong> Endovascular therapy has revolutionized the treatment of cerebral aneurysms in recent years and decades. So-called intrasaccular devices (i.e., Woven EndoBridge [WEB], MicroVention, Aliso Viejo, California, United States; or Contour, Cerus Neurovascular, Fremont, California, United States) are a promising endovascular technology, especially for wide-based aneurysms. However, long-term outcome data are currently particularly scarce for Contour and strategies for failed Contour cases are lacking. Here, we report the feasibility of microsurgical clipping after failed Contour device embolization.</p><p><strong>Methods: </strong> Feasibility of microsurgical clipping after failed aneurysm embolization with a Contour intrasaccular device was assessed in a patient.</p><p><strong>Results: </strong> We present the case of a 36-year-old male patient diagnosed with Hunt and Hess grade 1 subarachnoid hemorrhage from an anterior communicating artery aneurysm. The ruptured aneurysm was initially treated with the Contour device. After 3 months, angiographic imaging showed a clear aneurysm residual deemed not endovascularly accessible. The patient was then successfully clipped using microsurgical techniques. The patient was discharged with no neurologic abnormalities.</p><p><strong>Conclusion: </strong> After thorough bibliographical research, this presents the first published case report of microsurgical clipping after failed embolization with Contour. The main insights gained after clipping were that the Contour does not significantly disturb or hinder clipping. In contrast to coils in aneurysms to be clipped, the Contour can be easily compressed by the clip blades and does not have to be removed. In addition, the Contour had not migrated into the subarachnoid space and there was no abnormal scarring. Clipping appears to be a reasonable treatment strategy for failure of embolization with Contour if endovascular means are not suitable.</p>","PeriodicalId":16544,"journal":{"name":"Journal of neurological surgery. Part A, Central European neurosurgery","volume":" ","pages":"319-321"},"PeriodicalIF":0.9000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Microsurgical Clipping after Failed Contour Device Embolization of an Anterior Communicating Artery Aneurysm: Technical Note.\",\"authors\":\"Christoph J Griessenauer, Monika Killer-Oberpfalzer, Carlos M Beredjiklian, Manuel Lunzer\",\"doi\":\"10.1055/a-2103-7639\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong> Endovascular therapy has revolutionized the treatment of cerebral aneurysms in recent years and decades. So-called intrasaccular devices (i.e., Woven EndoBridge [WEB], MicroVention, Aliso Viejo, California, United States; or Contour, Cerus Neurovascular, Fremont, California, United States) are a promising endovascular technology, especially for wide-based aneurysms. However, long-term outcome data are currently particularly scarce for Contour and strategies for failed Contour cases are lacking. Here, we report the feasibility of microsurgical clipping after failed Contour device embolization.</p><p><strong>Methods: </strong> Feasibility of microsurgical clipping after failed aneurysm embolization with a Contour intrasaccular device was assessed in a patient.</p><p><strong>Results: </strong> We present the case of a 36-year-old male patient diagnosed with Hunt and Hess grade 1 subarachnoid hemorrhage from an anterior communicating artery aneurysm. The ruptured aneurysm was initially treated with the Contour device. After 3 months, angiographic imaging showed a clear aneurysm residual deemed not endovascularly accessible. The patient was then successfully clipped using microsurgical techniques. The patient was discharged with no neurologic abnormalities.</p><p><strong>Conclusion: </strong> After thorough bibliographical research, this presents the first published case report of microsurgical clipping after failed embolization with Contour. The main insights gained after clipping were that the Contour does not significantly disturb or hinder clipping. In contrast to coils in aneurysms to be clipped, the Contour can be easily compressed by the clip blades and does not have to be removed. In addition, the Contour had not migrated into the subarachnoid space and there was no abnormal scarring. Clipping appears to be a reasonable treatment strategy for failure of embolization with Contour if endovascular means are not suitable.</p>\",\"PeriodicalId\":16544,\"journal\":{\"name\":\"Journal of neurological surgery. Part A, Central European neurosurgery\",\"volume\":\" \",\"pages\":\"319-321\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neurological surgery. Part A, Central European neurosurgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2103-7639\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurological surgery. Part A, Central European neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2103-7639","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/31 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:近年来,血管内治疗彻底改变了脑动脉瘤的治疗方法。所谓的肌内装置(即 Woven EndoBridge [WEB],MicroVention,Aliso Viejo,California,United States;或 Contour,Cerus Neurovascular,Fremont,California,United States)是一种前景广阔的血管内技术,尤其适用于宽基动脉瘤。然而,目前关于 Contour 的长期结果数据尤其稀少,也缺乏针对 Contour 失败病例的策略。在此,我们报告了 Contour 装置栓塞失败后进行显微外科剪切的可行性:方法:在一名患者身上评估了使用 Contour 肌肉内装置栓塞动脉瘤失败后进行显微外科剪切的可行性:结果:我们介绍了一名 36 岁男性患者的病例,他被诊断为前交通动脉瘤导致的 Hunt 和 Hess 1 级蛛网膜下腔出血。最初使用 Contour 装置治疗破裂的动脉瘤。3 个月后,血管造影显示动脉瘤残余清晰,无法进行血管内治疗。随后,利用显微外科技术对患者进行了成功夹闭。患者出院时未出现神经系统异常:经过深入的文献研究,这是第一份发表的关于 Contour 栓塞失败后进行显微外科剪切的病例报告。剪切后获得的主要启示是,Contour 不会明显干扰或阻碍剪切。与要剪切的动脉瘤中的线圈相比,Contour 可以很容易地被夹片压缩,无需取出。此外,Contour 没有移入蛛网膜下腔,也没有异常疤痕。如果不适合采用血管内方法,那么夹闭似乎是一种合理的治疗策略,可用于 Contour 栓塞失败后的治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Microsurgical Clipping after Failed Contour Device Embolization of an Anterior Communicating Artery Aneurysm: Technical Note.

Background:  Endovascular therapy has revolutionized the treatment of cerebral aneurysms in recent years and decades. So-called intrasaccular devices (i.e., Woven EndoBridge [WEB], MicroVention, Aliso Viejo, California, United States; or Contour, Cerus Neurovascular, Fremont, California, United States) are a promising endovascular technology, especially for wide-based aneurysms. However, long-term outcome data are currently particularly scarce for Contour and strategies for failed Contour cases are lacking. Here, we report the feasibility of microsurgical clipping after failed Contour device embolization.

Methods:  Feasibility of microsurgical clipping after failed aneurysm embolization with a Contour intrasaccular device was assessed in a patient.

Results:  We present the case of a 36-year-old male patient diagnosed with Hunt and Hess grade 1 subarachnoid hemorrhage from an anterior communicating artery aneurysm. The ruptured aneurysm was initially treated with the Contour device. After 3 months, angiographic imaging showed a clear aneurysm residual deemed not endovascularly accessible. The patient was then successfully clipped using microsurgical techniques. The patient was discharged with no neurologic abnormalities.

Conclusion:  After thorough bibliographical research, this presents the first published case report of microsurgical clipping after failed embolization with Contour. The main insights gained after clipping were that the Contour does not significantly disturb or hinder clipping. In contrast to coils in aneurysms to be clipped, the Contour can be easily compressed by the clip blades and does not have to be removed. In addition, the Contour had not migrated into the subarachnoid space and there was no abnormal scarring. Clipping appears to be a reasonable treatment strategy for failure of embolization with Contour if endovascular means are not suitable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
90
期刊介绍: The Journal of Neurological Surgery Part A: Central European Neurosurgery (JNLS A) is a major publication from the world''s leading publisher in neurosurgery. JNLS A currently serves as the official organ of several national neurosurgery societies. JNLS A is a peer-reviewed journal publishing original research, review articles, and technical notes covering all aspects of neurological surgery. The focus of JNLS A includes microsurgery as well as the latest minimally invasive techniques, such as stereotactic-guided surgery, endoscopy, and endovascular procedures. JNLS A covers purely neurosurgical topics.
期刊最新文献
Vagal Nerve Stimulation in the Pediatric Population and Correlation between Family and Treatment Team Perspectives: Single-Center Experience. Combined one-step hybrid treatment for a paediatric giant internal carotid artery aneurysm: a case report. A New Concept for Cervical Expansion Screws Using Shape Memory Alloy: A Feasibility Study. Artificial Intelligence Prediction Model of Occurrence of Cerebral Vasospasms Based on Machine Learning. Paresis of the Oculomotor Nerve due to Neurovascular Conflict with Superior Cerebellar Artery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1