{"title":"血管周围医疗器械治疗内膜增生综述:机械因素和药物释放动力学的作用。","authors":"Ankur J Raval, Jigisha K Parikh, Meghal A Desai","doi":"10.1080/17434440.2023.2244875","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Intimal hyperplasia (IH) is a significant factor limiting the success of revascularization surgery for blood flow restoration. IH results from a foreign body response and mechanical disparity that involves complex biochemical reactions resulting in graft failure. The available treatment option utilizes either different pharmacological interventions or mechanical support to the vascular grafts with limited success.</p><p><strong>Areas covered: </strong>This review explains the pathophysiology of IH, responsible mechanical and biological factors, and treatment options, emphasizing perivascular devices. They are designed to provide mechanical support and pharmacology actions. The perivascular drug delivery concept has successfully demonstrated efficacy in various animal studies. Accurate projections of drug release mechanisms using mathematical modeling could be used to formulate prolonged drug elution devices. Numerical modeling aspects for the prediction of design outcomes have been given due importance that fulfills the unmet clinical need for better patient care.</p><p><strong>Expert opinion: </strong>IH could be effectively prevented by simultaneous mechanical scaffolding and sustained local drug delivery. Future perivascular medical devices could be designed to integrate these essential features. Numerical modeling for device performance prediction should be utilized in the development of next-generation perivascular devices.</p>","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A review on the treatment of intimal hyperplasia with perivascular medical devices: role of mechanical factors and drug release kinetics.\",\"authors\":\"Ankur J Raval, Jigisha K Parikh, Meghal A Desai\",\"doi\":\"10.1080/17434440.2023.2244875\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Intimal hyperplasia (IH) is a significant factor limiting the success of revascularization surgery for blood flow restoration. IH results from a foreign body response and mechanical disparity that involves complex biochemical reactions resulting in graft failure. The available treatment option utilizes either different pharmacological interventions or mechanical support to the vascular grafts with limited success.</p><p><strong>Areas covered: </strong>This review explains the pathophysiology of IH, responsible mechanical and biological factors, and treatment options, emphasizing perivascular devices. They are designed to provide mechanical support and pharmacology actions. The perivascular drug delivery concept has successfully demonstrated efficacy in various animal studies. Accurate projections of drug release mechanisms using mathematical modeling could be used to formulate prolonged drug elution devices. Numerical modeling aspects for the prediction of design outcomes have been given due importance that fulfills the unmet clinical need for better patient care.</p><p><strong>Expert opinion: </strong>IH could be effectively prevented by simultaneous mechanical scaffolding and sustained local drug delivery. Future perivascular medical devices could be designed to integrate these essential features. Numerical modeling for device performance prediction should be utilized in the development of next-generation perivascular devices.</p>\",\"PeriodicalId\":12330,\"journal\":{\"name\":\"Expert Review of Medical Devices\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert Review of Medical Devices\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2023.2244875\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Medical Devices","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2244875","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
A review on the treatment of intimal hyperplasia with perivascular medical devices: role of mechanical factors and drug release kinetics.
Introduction: Intimal hyperplasia (IH) is a significant factor limiting the success of revascularization surgery for blood flow restoration. IH results from a foreign body response and mechanical disparity that involves complex biochemical reactions resulting in graft failure. The available treatment option utilizes either different pharmacological interventions or mechanical support to the vascular grafts with limited success.
Areas covered: This review explains the pathophysiology of IH, responsible mechanical and biological factors, and treatment options, emphasizing perivascular devices. They are designed to provide mechanical support and pharmacology actions. The perivascular drug delivery concept has successfully demonstrated efficacy in various animal studies. Accurate projections of drug release mechanisms using mathematical modeling could be used to formulate prolonged drug elution devices. Numerical modeling aspects for the prediction of design outcomes have been given due importance that fulfills the unmet clinical need for better patient care.
Expert opinion: IH could be effectively prevented by simultaneous mechanical scaffolding and sustained local drug delivery. Future perivascular medical devices could be designed to integrate these essential features. Numerical modeling for device performance prediction should be utilized in the development of next-generation perivascular devices.
期刊介绍:
The journal serves the device research community by providing a comprehensive body of high-quality information from leading experts, all subject to rigorous peer review. The Expert Review format is specially structured to optimize the value of the information to reader. Comprehensive coverage by each author in a key area of research or clinical practice is augmented by the following sections:
Expert commentary - a personal view on the most effective or promising strategies
Five-year view - a clear perspective of future prospects within a realistic timescale
Key issues - an executive summary cutting to the author''s most critical points
In addition to the Review program, each issue also features Medical Device Profiles - objective assessments of specific devices in development or clinical use to help inform clinical practice. There are also Perspectives - overviews highlighting areas of current debate and controversy, together with reports from the conference scene and invited Editorials.