{"title":"用于生物医学应用的高灵敏度温度传感器,采用一维布拉格反射器。","authors":"Ranjith B Gowda, Preeta Sharan, Saara K","doi":"10.1515/bmt-2022-0482","DOIUrl":null,"url":null,"abstract":"<p><p>A theoretical investigation of multi-layer Bragg Reflector (BR) structure to design highly sensitive temperature sensor is proposed to measure the temperature over a wide range. Characteristic-Matrix (CM) mathematical tool is used to design and analyse the proposed temperature sensor. A 1D Distributed Bragg Reflector multi-layer structure is used to design and analyse the sensing characteristics of the proposed sensor. Periodic modulation in the Refractive-Index (RI) of the two materials, high and low, forms DBR multi-layer structure. Germanium and air are used as the two alternate materials of BR for high and low dielectric layers respectively. Parameters of many semiconductor materials, including germanium, varies with temperature. Here we have considered RI variation of germanium with the temperature to model and design the proposed sensor. A defect layer is introduced at the center of multi-layer structure to obtain the resonating mode for an incident electromagnetic wave. The sensor can detect temperature over a wide range from 100 to 550 K. A resonating mode, shifting towards different wavelength region is observed for the temperature variations. The influence of increase in the DBR layers (N) and defect cavity geometrical length (l<sub>D</sub>) is studied. The obtained results conclude that the cavity defect length and BR layers affects the sensing parameters of the designed sensor. The obtained RI sensitivity, Q-factor, temperature sensitivity and detection limit of the sensor are 2.323 μm/RIU, 115,000, 1.18 nm/K and 9.024 × 10<sup>-6</sup> RIU respectively. Theoretically obtained transmission spectrum was validated using Monte Carlo simulation.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Highly sensitive temperature sensor using one-dimensional Bragg Reflector for biomedical applications.\",\"authors\":\"Ranjith B Gowda, Preeta Sharan, Saara K\",\"doi\":\"10.1515/bmt-2022-0482\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A theoretical investigation of multi-layer Bragg Reflector (BR) structure to design highly sensitive temperature sensor is proposed to measure the temperature over a wide range. Characteristic-Matrix (CM) mathematical tool is used to design and analyse the proposed temperature sensor. A 1D Distributed Bragg Reflector multi-layer structure is used to design and analyse the sensing characteristics of the proposed sensor. Periodic modulation in the Refractive-Index (RI) of the two materials, high and low, forms DBR multi-layer structure. Germanium and air are used as the two alternate materials of BR for high and low dielectric layers respectively. Parameters of many semiconductor materials, including germanium, varies with temperature. Here we have considered RI variation of germanium with the temperature to model and design the proposed sensor. A defect layer is introduced at the center of multi-layer structure to obtain the resonating mode for an incident electromagnetic wave. The sensor can detect temperature over a wide range from 100 to 550 K. A resonating mode, shifting towards different wavelength region is observed for the temperature variations. The influence of increase in the DBR layers (N) and defect cavity geometrical length (l<sub>D</sub>) is studied. The obtained results conclude that the cavity defect length and BR layers affects the sensing parameters of the designed sensor. The obtained RI sensitivity, Q-factor, temperature sensitivity and detection limit of the sensor are 2.323 μm/RIU, 115,000, 1.18 nm/K and 9.024 × 10<sup>-6</sup> RIU respectively. Theoretically obtained transmission spectrum was validated using Monte Carlo simulation.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1515/bmt-2022-0482\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1515/bmt-2022-0482","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Highly sensitive temperature sensor using one-dimensional Bragg Reflector for biomedical applications.
A theoretical investigation of multi-layer Bragg Reflector (BR) structure to design highly sensitive temperature sensor is proposed to measure the temperature over a wide range. Characteristic-Matrix (CM) mathematical tool is used to design and analyse the proposed temperature sensor. A 1D Distributed Bragg Reflector multi-layer structure is used to design and analyse the sensing characteristics of the proposed sensor. Periodic modulation in the Refractive-Index (RI) of the two materials, high and low, forms DBR multi-layer structure. Germanium and air are used as the two alternate materials of BR for high and low dielectric layers respectively. Parameters of many semiconductor materials, including germanium, varies with temperature. Here we have considered RI variation of germanium with the temperature to model and design the proposed sensor. A defect layer is introduced at the center of multi-layer structure to obtain the resonating mode for an incident electromagnetic wave. The sensor can detect temperature over a wide range from 100 to 550 K. A resonating mode, shifting towards different wavelength region is observed for the temperature variations. The influence of increase in the DBR layers (N) and defect cavity geometrical length (lD) is studied. The obtained results conclude that the cavity defect length and BR layers affects the sensing parameters of the designed sensor. The obtained RI sensitivity, Q-factor, temperature sensitivity and detection limit of the sensor are 2.323 μm/RIU, 115,000, 1.18 nm/K and 9.024 × 10-6 RIU respectively. Theoretically obtained transmission spectrum was validated using Monte Carlo simulation.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.