透明矫治器正畸治疗中使用的树脂附件的表面磨损和粘合失效。

IF 1.3 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie Pub Date : 2024-05-01 Epub Date: 2023-06-14 DOI:10.1007/s00056-023-00471-5
Alexandre Fausto da Veiga Jardim, Jairo Curado de Freitas, Carlos Estrela
{"title":"透明矫治器正畸治疗中使用的树脂附件的表面磨损和粘合失效。","authors":"Alexandre Fausto da Veiga Jardim, Jairo Curado de Freitas, Carlos Estrela","doi":"10.1007/s00056-023-00471-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated adhesive and cohesive failures and the surface wear of attachments employed in clear aligner treatment (CAT) using three-dimensional (3D) superimposition.</p><p><strong>Methods: </strong>In all, 3D models of 150 teeth were obtained from intraoral scans from patients undergoing CAT with at least 4 months between each scan. Of the initial sample, 25 teeth were discarded, and 125 teeth were included in the study. Superimpositions of each individual tooth at the first and second time points were made using computer-aided design (CAD) software (Meshmixer; Autodesk, Mill Valley, CA, USA). Analyses were performed to compare surface wear and failures related to type of attachment (optimized/conventional), dental group (molars/premolars/anterior teeth), and arch (mandibular/maxillary). Mann-Whitney and Kruskal-Wallis statistical tests were applied with significance set at 5%.</p><p><strong>Results: </strong>More surface wear was observed in conventional attachments, mandibular and anterior teeth with statistical significance for surface wear on the distal surface of conventional attachments (p < 0.05). Cohesive failure was observed in 10% of attachments, occurring most frequently on optimized attachments and molar teeth. Adhesive failure was observed in 10% of the samples, more frequently on conventional attachments and posterior teeth.</p><p><strong>Conclusion: </strong>Attachment type (conventional vs. optimized) was significantly correlated with surface wear on the distal surface of the attachment. Arch (mandibular or maxillary) and group of teeth (anterior or posterior) showed no correlation with surface wear. Failure, both adhesive and cohesive, correlated with attachment type and group of teeth, but not with the arch in which they were located.</p>","PeriodicalId":54776,"journal":{"name":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","volume":" ","pages":"52-62"},"PeriodicalIF":1.3000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Surface wear and adhesive failure of resin attachments used in clear aligner orthodontic treatment.\",\"authors\":\"Alexandre Fausto da Veiga Jardim, Jairo Curado de Freitas, Carlos Estrela\",\"doi\":\"10.1007/s00056-023-00471-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study evaluated adhesive and cohesive failures and the surface wear of attachments employed in clear aligner treatment (CAT) using three-dimensional (3D) superimposition.</p><p><strong>Methods: </strong>In all, 3D models of 150 teeth were obtained from intraoral scans from patients undergoing CAT with at least 4 months between each scan. Of the initial sample, 25 teeth were discarded, and 125 teeth were included in the study. Superimpositions of each individual tooth at the first and second time points were made using computer-aided design (CAD) software (Meshmixer; Autodesk, Mill Valley, CA, USA). Analyses were performed to compare surface wear and failures related to type of attachment (optimized/conventional), dental group (molars/premolars/anterior teeth), and arch (mandibular/maxillary). Mann-Whitney and Kruskal-Wallis statistical tests were applied with significance set at 5%.</p><p><strong>Results: </strong>More surface wear was observed in conventional attachments, mandibular and anterior teeth with statistical significance for surface wear on the distal surface of conventional attachments (p < 0.05). Cohesive failure was observed in 10% of attachments, occurring most frequently on optimized attachments and molar teeth. Adhesive failure was observed in 10% of the samples, more frequently on conventional attachments and posterior teeth.</p><p><strong>Conclusion: </strong>Attachment type (conventional vs. optimized) was significantly correlated with surface wear on the distal surface of the attachment. Arch (mandibular or maxillary) and group of teeth (anterior or posterior) showed no correlation with surface wear. Failure, both adhesive and cohesive, correlated with attachment type and group of teeth, but not with the arch in which they were located.</p>\",\"PeriodicalId\":54776,\"journal\":{\"name\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"volume\":\" \",\"pages\":\"52-62\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00056-023-00471-5\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00056-023-00471-5","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究使用三维(3D)叠加法评估了透明矫治器治疗(CAT)中使用的附着体的粘附性和内聚性失效以及表面磨损情况:从接受透明矫治器治疗的患者口内扫描中获得了 150 颗牙齿的三维模型,每次扫描间隔至少 4 个月。在初始样本中,剔除了 25 颗牙齿,将 125 颗牙齿纳入研究。使用计算机辅助设计(CAD)软件(Meshmixer;Autodesk,Mill Valley,CA,USA)对第一和第二个时间点的每颗牙齿进行叠加。分析比较了与附着类型(优化/传统)、牙齿组别(臼齿/前臼齿/前牙)和牙弓(下颌/上颌)相关的表面磨损和故障。采用 Mann-Whitney 和 Kruskal-Wallis 统计检验,显著性设定为 5%:结果:传统附着体、下颌牙和前牙的表面磨损更严重,传统附着体远端表面的表面磨损具有统计学意义(p 结论:传统附着体的表面磨损更严重:附着体类型(传统附着体与优化附着体)与附着体远端表面的表面磨损有显著相关性。牙弓(下颌或上颌)和牙齿组别(前牙或后牙)与表面磨损没有相关性。粘附性和内聚性失效与附着体类型和牙齿组别有关,但与所在牙弓无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Surface wear and adhesive failure of resin attachments used in clear aligner orthodontic treatment.

Purpose: This study evaluated adhesive and cohesive failures and the surface wear of attachments employed in clear aligner treatment (CAT) using three-dimensional (3D) superimposition.

Methods: In all, 3D models of 150 teeth were obtained from intraoral scans from patients undergoing CAT with at least 4 months between each scan. Of the initial sample, 25 teeth were discarded, and 125 teeth were included in the study. Superimpositions of each individual tooth at the first and second time points were made using computer-aided design (CAD) software (Meshmixer; Autodesk, Mill Valley, CA, USA). Analyses were performed to compare surface wear and failures related to type of attachment (optimized/conventional), dental group (molars/premolars/anterior teeth), and arch (mandibular/maxillary). Mann-Whitney and Kruskal-Wallis statistical tests were applied with significance set at 5%.

Results: More surface wear was observed in conventional attachments, mandibular and anterior teeth with statistical significance for surface wear on the distal surface of conventional attachments (p < 0.05). Cohesive failure was observed in 10% of attachments, occurring most frequently on optimized attachments and molar teeth. Adhesive failure was observed in 10% of the samples, more frequently on conventional attachments and posterior teeth.

Conclusion: Attachment type (conventional vs. optimized) was significantly correlated with surface wear on the distal surface of the attachment. Arch (mandibular or maxillary) and group of teeth (anterior or posterior) showed no correlation with surface wear. Failure, both adhesive and cohesive, correlated with attachment type and group of teeth, but not with the arch in which they were located.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
0.00%
发文量
64
审稿时长
>12 weeks
期刊介绍: The Journal of Orofacial Orthopedics provides orthodontists and dentists who are also actively interested in orthodontics, whether in university clinics or private practice, with highly authoritative and up-to-date information based on experimental and clinical research. The journal is one of the leading publications for the promulgation of the results of original work both in the areas of scientific and clinical orthodontics and related areas. All articles undergo peer review before publication. The German Society of Orthodontics (DGKFO) also publishes in the journal important communications, statements and announcements.
期刊最新文献
Effect of tube debonding on the enamel surface in vitro : Evaluation with optical coherence tomography. Development and in vitro testing of an orthodontic miniscrew for use in the mandible. The effects of professional expertise on perceptions of treatment need in patients with class II division 1 malocclusion: a comparison between orthodontists, general dentists, and lay people in Germany. Mitteilungen der DGKFO. Effect of orthodontic extraction of mandibular premolars on third molar angulation after treatment with fixed appliances : A cross-sectional study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1