握力与贾马尔:一种评估握力的新测力计的挑战。

IF 4.3 2区 医学 Q1 GERIATRICS & GERONTOLOGY Journals of Gerontology Series A-Biological Sciences and Medical Sciences Pub Date : 2023-12-01 DOI:10.1093/gerona/glad198
Cédric Villain, Soazig Lebaube, Corinne Kremer, Chantal Chavoix, François Fournel, Anaïs R Briant, Bérengère Beauplet
{"title":"握力与贾马尔:一种评估握力的新测力计的挑战。","authors":"Cédric Villain, Soazig Lebaube, Corinne Kremer, Chantal Chavoix, François Fournel, Anaïs R Briant, Bérengère Beauplet","doi":"10.1093/gerona/glad198","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Sarcopenia diagnosis is partly based on handgrip strength (HGS) assessment. The gold-standard dynamometer for this measurement is the Jamar. The electronic Gripwise is a smaller and lighter one, and its measurements are correlated with the Jamar's in laboratory tests. Our study aimed to confirm this correlation in aged patients.</p><p><strong>Methods: </strong>This monocenter cross-sectional study was performed in patients of 65 years and older admitted at the University Hospital. Participants were assessed either in a seated or bedridden position, randomly allocated to begin the measurements with the Jamar or the Gripwise.</p><p><strong>Results: </strong>Among 649 aged inpatients assessed for eligibility, 348 were included (mean age: 79 ± 9; 52% females). The intraclass correlation coefficient was 0.93 (95% confidence interval [CI] 0.92-0.94, p < .001) for the maximum value measured with both devices and 0.94 (95% CI 0.93-0.95, p < .001) for the mean values. However, there was a significant difference in detecting low values (<16 kg in women, <27 kg in men), found in 48% of patients with Jamar, and 71% with Gripwise (p < .001). Thus, we determined alternate cutoffs for diagnosing HGS low values with the Gripwise (<12 kg in women, <22 kg in men), further validated in a supplementary validation population (n = 70). The diagnostic performances of these alternative cutoffs were high (93% sensitivity and 87% specificity in women; 94% sensitivity and 96% specificity in men).</p><p><strong>Conclusions: </strong>The correlation of the Gripwise with the Jamar was confirmed in aged inpatients. However, lower values recorded with the Gripwise require alternate cutoffs for a relevant low HGS diagnosis.</p>","PeriodicalId":49953,"journal":{"name":"Journals of Gerontology Series A-Biological Sciences and Medical Sciences","volume":" ","pages":"2458-2465"},"PeriodicalIF":4.3000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692423/pdf/","citationCount":"0","resultStr":"{\"title\":\"Gripwise Versus Jamar: The Challenge of a New Dynamometer Assessing Handgrip Strength.\",\"authors\":\"Cédric Villain, Soazig Lebaube, Corinne Kremer, Chantal Chavoix, François Fournel, Anaïs R Briant, Bérengère Beauplet\",\"doi\":\"10.1093/gerona/glad198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Sarcopenia diagnosis is partly based on handgrip strength (HGS) assessment. The gold-standard dynamometer for this measurement is the Jamar. The electronic Gripwise is a smaller and lighter one, and its measurements are correlated with the Jamar's in laboratory tests. Our study aimed to confirm this correlation in aged patients.</p><p><strong>Methods: </strong>This monocenter cross-sectional study was performed in patients of 65 years and older admitted at the University Hospital. Participants were assessed either in a seated or bedridden position, randomly allocated to begin the measurements with the Jamar or the Gripwise.</p><p><strong>Results: </strong>Among 649 aged inpatients assessed for eligibility, 348 were included (mean age: 79 ± 9; 52% females). The intraclass correlation coefficient was 0.93 (95% confidence interval [CI] 0.92-0.94, p < .001) for the maximum value measured with both devices and 0.94 (95% CI 0.93-0.95, p < .001) for the mean values. However, there was a significant difference in detecting low values (<16 kg in women, <27 kg in men), found in 48% of patients with Jamar, and 71% with Gripwise (p < .001). Thus, we determined alternate cutoffs for diagnosing HGS low values with the Gripwise (<12 kg in women, <22 kg in men), further validated in a supplementary validation population (n = 70). The diagnostic performances of these alternative cutoffs were high (93% sensitivity and 87% specificity in women; 94% sensitivity and 96% specificity in men).</p><p><strong>Conclusions: </strong>The correlation of the Gripwise with the Jamar was confirmed in aged inpatients. However, lower values recorded with the Gripwise require alternate cutoffs for a relevant low HGS diagnosis.</p>\",\"PeriodicalId\":49953,\"journal\":{\"name\":\"Journals of Gerontology Series A-Biological Sciences and Medical Sciences\",\"volume\":\" \",\"pages\":\"2458-2465\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692423/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journals of Gerontology Series A-Biological Sciences and Medical Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/gerona/glad198\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"GERIATRICS & GERONTOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journals of Gerontology Series A-Biological Sciences and Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/gerona/glad198","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GERIATRICS & GERONTOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:肌肉减少症的诊断部分基于握力(HGS)评估。这个测量的黄金标准测功机是Jamar。电子Gripwise更小更轻,其测量值与实验室测试中的Jamar相关联。我们的研究旨在证实老年患者的这种相关性。方法:本单中心横断面研究在大学医院收治的65岁及以上患者中进行。参与者要么坐着,要么卧床,随机分配使用Jamar或Gripwise开始测量。结果:649例老年住院患者中,348例入选(平均年龄79±9岁;52%的女性)。组内相关系数为0.93(95%可信区间[CI] 0.92 ~ 0.94, p)。结论:老年住院患者Gripwise与Jamar的相关性得到证实。然而,Gripwise记录的较低数值需要替代截断值以进行相关的低HGS诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Gripwise Versus Jamar: The Challenge of a New Dynamometer Assessing Handgrip Strength.

Background: Sarcopenia diagnosis is partly based on handgrip strength (HGS) assessment. The gold-standard dynamometer for this measurement is the Jamar. The electronic Gripwise is a smaller and lighter one, and its measurements are correlated with the Jamar's in laboratory tests. Our study aimed to confirm this correlation in aged patients.

Methods: This monocenter cross-sectional study was performed in patients of 65 years and older admitted at the University Hospital. Participants were assessed either in a seated or bedridden position, randomly allocated to begin the measurements with the Jamar or the Gripwise.

Results: Among 649 aged inpatients assessed for eligibility, 348 were included (mean age: 79 ± 9; 52% females). The intraclass correlation coefficient was 0.93 (95% confidence interval [CI] 0.92-0.94, p < .001) for the maximum value measured with both devices and 0.94 (95% CI 0.93-0.95, p < .001) for the mean values. However, there was a significant difference in detecting low values (<16 kg in women, <27 kg in men), found in 48% of patients with Jamar, and 71% with Gripwise (p < .001). Thus, we determined alternate cutoffs for diagnosing HGS low values with the Gripwise (<12 kg in women, <22 kg in men), further validated in a supplementary validation population (n = 70). The diagnostic performances of these alternative cutoffs were high (93% sensitivity and 87% specificity in women; 94% sensitivity and 96% specificity in men).

Conclusions: The correlation of the Gripwise with the Jamar was confirmed in aged inpatients. However, lower values recorded with the Gripwise require alternate cutoffs for a relevant low HGS diagnosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.00
自引率
5.90%
发文量
233
审稿时长
3-8 weeks
期刊介绍: Publishes articles representing the full range of medical sciences pertaining to aging. Appropriate areas include, but are not limited to, basic medical science, clinical epidemiology, clinical research, and health services research for professions such as medicine, dentistry, allied health sciences, and nursing. It publishes articles on research pertinent to human biology and disease.
期刊最新文献
Hypoxanthine Induces Signs of Bladder Aging With Voiding Dysfunction and Lower Urinary Tract Remodeling. Skeletal Muscle Health, Physical Performance, and Lower Urinary Tract Symptoms in Older Adults: The Study of Muscle, Mobility, and Aging. Establishment of Baseline Urinary Antimicrobial Peptide Levels by Age: A Prospective Observational Study. First Observations of a Potential Association Between Accumulation of Per- and Polyfluoroalkyl Substances in the Central Nervous System and Markers of Alzheimer's Disease. No Associations Between Glucosamine Supplementation and Dementia or Parkinson's Disease: Findings From a Large Prospective Cohort Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1