Carbon-fibre plates for traumatic and (impending) pathological fracture fixation: Where do we stand? A systematic review.

IF 3 2区 医学 Q1 ORTHOPEDICS Journal of Orthopaedics and Traumatology Pub Date : 2023-08-11 DOI:10.1186/s10195-023-00724-4
Zeger Rijs, Amber Weekhout, Stef Daniel, Jan W Schoones, Olivier Q Groot, Santiago A Lozano-Calderon, Michiel A J van de Sande
{"title":"Carbon-fibre plates for traumatic and (impending) pathological fracture fixation: Where do we stand? A systematic review.","authors":"Zeger Rijs, Amber Weekhout, Stef Daniel, Jan W Schoones, Olivier Q Groot, Santiago A Lozano-Calderon, Michiel A J van de Sande","doi":"10.1186/s10195-023-00724-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Carbon-fibre (CF) plates are increasingly used for fracture fixation. This systematic review evaluated complications associated with CF plate fixation. It also compared outcomes of patients treated with CF plates versus metal plates, aiming to determine if CF plates offered comparable results. The study hypothesized that CF plates display similar complication rates and clinical outcomes as metal plates for fracture fixation.</p><p><strong>Methods: </strong>The study adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were searched from database inception until June 2023: PubMed, MEDLINE, Embase, Web of Science, Cochrane Library, Emcare, Academic Search Premier and Google Scholar. Studies reporting on clinical and radiological outcomes of patients treated with CF plates for traumatic fractures and (impending) pathological fractures were included. Study quality was assessed, and complications were documented as number and percentage per anatomic region.</p><p><strong>Results: </strong>A total of 27 studies of moderate to very low quality of evidence were included. Of these, 22 studies (800 patients, median follow-up 12 months) focused on traumatic fractures, and 5 studies (102 patients, median follow-up 12 months) on (impending) pathological fractures. A total of 11 studies (497 patients, median follow-up 16 months) compared CF plates with metal plates. Regarding traumatic fractures, the following complications were mostly reported: soft tissue complications (52 out of 391; 13%) for the humerus, structural complications (6 out of 291; 2%) for the distal radius, nonunion and structural complication (1 out of 34; 3%) for the femur, and infection (4 out of 104; 4%) for the ankle. For (impending) pathological fractures, the most frequently reported complications were infections (2 out of 14; 14%) for the humerus and structural complication (6 out of 86; 7%) for the femur/tibia. Comparative studies reported mixed results, although the majority (7 out of 11; 64%) reported no significant differences in clinical or radiological outcomes between patients treated with CF or metal plates.</p><p><strong>Conclusion: </strong>This systematic review did not reveal a concerning number of complications related to CF plate fixation. Comparative studies showed no significant differences between CF plates and metal plates for traumatic fracture fixation. Therefore, CF plates appear to be a viable alternative to metal plates. However, high-quality randomized controlled trials (RCTs) with long-term follow-up are strongly recommended to provide additional evidence supporting the use of CF plates.</p><p><strong>Level of evidence: </strong>III, systematic review.</p>","PeriodicalId":48603,"journal":{"name":"Journal of Orthopaedics and Traumatology","volume":"24 1","pages":"42"},"PeriodicalIF":3.0000,"publicationDate":"2023-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421838/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedics and Traumatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s10195-023-00724-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Carbon-fibre (CF) plates are increasingly used for fracture fixation. This systematic review evaluated complications associated with CF plate fixation. It also compared outcomes of patients treated with CF plates versus metal plates, aiming to determine if CF plates offered comparable results. The study hypothesized that CF plates display similar complication rates and clinical outcomes as metal plates for fracture fixation.

Methods: The study adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were searched from database inception until June 2023: PubMed, MEDLINE, Embase, Web of Science, Cochrane Library, Emcare, Academic Search Premier and Google Scholar. Studies reporting on clinical and radiological outcomes of patients treated with CF plates for traumatic fractures and (impending) pathological fractures were included. Study quality was assessed, and complications were documented as number and percentage per anatomic region.

Results: A total of 27 studies of moderate to very low quality of evidence were included. Of these, 22 studies (800 patients, median follow-up 12 months) focused on traumatic fractures, and 5 studies (102 patients, median follow-up 12 months) on (impending) pathological fractures. A total of 11 studies (497 patients, median follow-up 16 months) compared CF plates with metal plates. Regarding traumatic fractures, the following complications were mostly reported: soft tissue complications (52 out of 391; 13%) for the humerus, structural complications (6 out of 291; 2%) for the distal radius, nonunion and structural complication (1 out of 34; 3%) for the femur, and infection (4 out of 104; 4%) for the ankle. For (impending) pathological fractures, the most frequently reported complications were infections (2 out of 14; 14%) for the humerus and structural complication (6 out of 86; 7%) for the femur/tibia. Comparative studies reported mixed results, although the majority (7 out of 11; 64%) reported no significant differences in clinical or radiological outcomes between patients treated with CF or metal plates.

Conclusion: This systematic review did not reveal a concerning number of complications related to CF plate fixation. Comparative studies showed no significant differences between CF plates and metal plates for traumatic fracture fixation. Therefore, CF plates appear to be a viable alternative to metal plates. However, high-quality randomized controlled trials (RCTs) with long-term follow-up are strongly recommended to provide additional evidence supporting the use of CF plates.

Level of evidence: III, systematic review.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
碳纤维钢板用于创伤性和(即将发生的)病理性骨折固定:我们的立场在哪里?系统回顾。
背景:碳纤维(CF)钢板越来越多地用于骨折固定。本系统综述评估了CF钢板固定相关的并发症。它还比较了CF钢板与金属钢板治疗的患者的结果,旨在确定CF钢板是否提供可比较的结果。该研究假设CF钢板与金属钢板在骨折固定中的并发症发生率和临床结果相似。方法:本研究遵循系统评价和荟萃分析指南的首选报告项目。从数据库建立到2023年6月,检索了以下数据库:PubMed, MEDLINE, Embase, Web of Science, Cochrane Library, Emcare, Academic Search Premier和谷歌Scholar。研究报告了CF钢板治疗外伤性骨折和(即将发生的)病理性骨折的临床和影像学结果。评估研究质量,记录每个解剖区域的并发症数量和百分比。结果:共纳入了27项证据质量中至极低的研究。其中,22项研究(800例患者,中位随访12个月)关注外伤性骨折,5项研究(102例患者,中位随访12个月)关注(即将发生的)病理性骨折。共有11项研究(497例患者,中位随访16个月)比较CF钢板与金属钢板。对于外伤性骨折,以下并发症报道最多:软组织并发症(391例中有52例;13%)肱骨,结构性并发症(291例中有6例;2%)为桡骨远端、骨不连和结构并发症(1 / 34;3%),感染(104例中有4例;4%)脚踝。对于(即将发生的)病理性骨折,最常见的并发症是感染(14例中2例;14%)为肱骨和结构并发症(86例中有6例;7%)为股骨/胫骨。比较研究报告的结果好坏参半,尽管大多数(11人中有7人;64%)报告CF或金属钢板治疗患者的临床或放射学结果无显著差异。结论:本系统综述未发现CF板固定相关并发症的数量。比较研究显示CF钢板与金属钢板在外伤性骨折固定中无显著差异。因此,CF板似乎是一个可行的替代金属板。然而,强烈推荐高质量的随机对照试验(RCTs)进行长期随访,以提供支持CF钢板使用的额外证据。证据等级:III级,系统评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Orthopaedics and Traumatology
Journal of Orthopaedics and Traumatology Medicine-Orthopedics and Sports Medicine
CiteScore
4.30
自引率
0.00%
发文量
56
审稿时长
13 weeks
期刊介绍: The Journal of Orthopaedics and Traumatology, the official open access peer-reviewed journal of the Italian Society of Orthopaedics and Traumatology, publishes original papers reporting basic or clinical research in the field of orthopaedic and traumatologic surgery, as well as systematic reviews, brief communications, case reports and letters to the Editor. Narrative instructional reviews and commentaries to original articles may be commissioned by Editors from eminent colleagues. The Journal of Orthopaedics and Traumatology aims to be an international forum for the communication and exchange of ideas concerning the various aspects of orthopaedics and musculoskeletal trauma.
期刊最新文献
Different patterns of neurogenic quadrilateral space syndrome: a case series of undefined posterior shoulder pain. MRI in the evaluation of plantar plate disease: diagnostic value of the "stress test". Current trends in the medial side of the knee: not only medial collateral ligament (MCL). The ligamentum teres and its role in hip arthroscopy for femoroacetabular impingement: a systematic review. Differences in microorganism profile in periprosthetic joint infections of the hip in patients affected by chronic kidney disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1