First clinical experience of a ring-configured cadmium zinc telluride camera: A comparative study versus conventional gamma camera systems

IF 1.3 4区 医学 Q4 PHYSIOLOGY Clinical Physiology and Functional Imaging Pub Date : 2023-08-17 DOI:10.1111/cpf.12853
Irma Cerić Andelius, David Minarik, Eva Persson, Henrik Mosén, Kristian Valind, Elin Trägårdh, Jenny Oddstig
{"title":"First clinical experience of a ring-configured cadmium zinc telluride camera: A comparative study versus conventional gamma camera systems","authors":"Irma Cerić Andelius,&nbsp;David Minarik,&nbsp;Eva Persson,&nbsp;Henrik Mosén,&nbsp;Kristian Valind,&nbsp;Elin Trägårdh,&nbsp;Jenny Oddstig","doi":"10.1111/cpf.12853","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>A novel semiconductor cadmium zinc telluride (CZT) gamma camera system using a block sequential regularized expectation maximization (BSREM) reconstruction algorithm is now clinically available. Here we investigate how a multi-purpose ring-configurated CZT system can be safely applied in clinics and describe the initial optimization process.</p>\n </section>\n \n <section>\n \n <h3> Method</h3>\n \n <p>Seventy-six patients (bone-, cardiac- and lung scan) were scanned on a conventional gamma camera (planar and/or single-photon emission computed tomography [SPECT]/SPECT-CT) used in clinical routine and on the ring-configurated CZT camera Starguide (GE Healthcare). These data were used to validate and optimize the Starguide system for routine clinical use.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Comparable image quality for the Starguide system, to that of the conventional gamma camera, was achieved for bone scan (4 min/bed position [BP] using a relative difference prior [RDP] with gamma 2 and beta 0.4, along with 10 iterations and 10 subsets), cardiac scan (8 min [stress] and 3 min 20 s [rest] using median root prior [MRP] with beta 0.07 non attenuation corrected and 0.008 attenuation corrected and 50 interations and 10 subsets for both stress and rest) and lung scan (10 min [vent] and 5 min [perf] using RDP with gamma 0.5 and beta 0.03 [vent] and 0.02 [perf] and 20 interations and 10 subsets for both vent and perf).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>It was possible to transition from a conventional gamma camera to the Starguide system as part of the clinical routine, with acceptable image quality. Images from the Starguide system were deemed to be at least as good as those from a conventional gamma camera.</p>\n </section>\n </div>","PeriodicalId":10504,"journal":{"name":"Clinical Physiology and Functional Imaging","volume":"44 1","pages":"79-88"},"PeriodicalIF":1.3000,"publicationDate":"2023-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cpf.12853","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Physiology and Functional Imaging","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cpf.12853","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

A novel semiconductor cadmium zinc telluride (CZT) gamma camera system using a block sequential regularized expectation maximization (BSREM) reconstruction algorithm is now clinically available. Here we investigate how a multi-purpose ring-configurated CZT system can be safely applied in clinics and describe the initial optimization process.

Method

Seventy-six patients (bone-, cardiac- and lung scan) were scanned on a conventional gamma camera (planar and/or single-photon emission computed tomography [SPECT]/SPECT-CT) used in clinical routine and on the ring-configurated CZT camera Starguide (GE Healthcare). These data were used to validate and optimize the Starguide system for routine clinical use.

Results

Comparable image quality for the Starguide system, to that of the conventional gamma camera, was achieved for bone scan (4 min/bed position [BP] using a relative difference prior [RDP] with gamma 2 and beta 0.4, along with 10 iterations and 10 subsets), cardiac scan (8 min [stress] and 3 min 20 s [rest] using median root prior [MRP] with beta 0.07 non attenuation corrected and 0.008 attenuation corrected and 50 interations and 10 subsets for both stress and rest) and lung scan (10 min [vent] and 5 min [perf] using RDP with gamma 0.5 and beta 0.03 [vent] and 0.02 [perf] and 20 interations and 10 subsets for both vent and perf).

Conclusions

It was possible to transition from a conventional gamma camera to the Starguide system as part of the clinical routine, with acceptable image quality. Images from the Starguide system were deemed to be at least as good as those from a conventional gamma camera.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
环形镉锌碲化照相机的首次临床应用:与传统伽马照相机系统的比较研究。
背景:一种新型的半导体碲化镉锌(CZT)伽马相机系统使用了块顺序正则化期望最大化(BSREM)重建算法,现已临床可用。在这里,我们研究了一个多用途环形CZT系统如何安全地应用于临床,并描述了初始优化过程。方法:76例患者(骨、心、肺扫描)在临床常规使用的传统伽玛相机(平面和/或单光子发射计算机断层扫描[SPECT]/SPECT- ct)和环形配置CZT相机Starguide (GE Healthcare)上进行扫描。这些数据用于验证和优化Starguide系统的常规临床应用。结果:在骨扫描中,Starguide系统的图像质量与传统伽玛相机相当(使用gamma 2和beta 0.4的相对差分先验[RDP],以及10次迭代和10个子集,每床位置[BP] 4分钟)。心脏扫描(8分钟[压力]和3分钟20秒[休息],使用中位数根先验[MRP], β 0.07非衰减校正和0.008衰减校正,压力和休息均为50次和10个子集)和肺部扫描(10分钟[通气]和5分钟[通气],使用RDP, γ 0.5和β 0.03[通气]和0.02[通气],通气和通气均为20次和10个子集)。结论:作为临床常规的一部分,从传统的伽玛相机过渡到Starguide系统是可能的,并且图像质量可以接受。星导系统的图像被认为至少与传统伽马相机的图像一样好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.40
自引率
5.60%
发文量
62
审稿时长
6-12 weeks
期刊介绍: Clinical Physiology and Functional Imaging publishes reports on clinical and experimental research pertinent to human physiology in health and disease. The scope of the Journal is very broad, covering all aspects of the regulatory system in the cardiovascular, renal and pulmonary systems with special emphasis on methodological aspects. The focus for the journal is, however, work that has potential clinical relevance. The Journal also features review articles on recent front-line research within these fields of interest. Covered by the major abstracting services including Current Contents and Science Citation Index, Clinical Physiology and Functional Imaging plays an important role in providing effective and productive communication among clinical physiologists world-wide.
期刊最新文献
Impact of structural factors around the accessory nerve on the pathogenesis of essential neck and upper-back stiffness: a sonographic investigation. Skin tissue dielectric constant: Time of day and skin depth dependence. Utility of fat-free adipose tissue correction formula for tracking body composition changes with dual-energy X-ray absorptiometry. Correlation between antihypertensive drugs and cerebral hemodynamic parameters: insights from observational findings using transcranial Doppler. Total and appendicular body composition comparisons between near-infrared reactance spectroscopy and dual energy X-ray absorptiometry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1