Harold A Prada-Ramírez, Sandra Celeita, Juan Camilo Fonseca
{"title":"Validation of a Rapid Microbiological Method for the Detection and Quantification of the Burkholderia cepacia Complex in an Antacid Oral Suspension.","authors":"Harold A Prada-Ramírez, Sandra Celeita, Juan Camilo Fonseca","doi":"10.1093/jaoacint/qsad056","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Despite the broad adoption of Soleris® technology in the food industry as semiquantitative method, it is almost completely unexplored in the pharmaceutical industry as a quantitative method for quantification of Burkholderia cepacia complex (Bcc).</p><p><strong>Objective: </strong>The efficacy of an automated growth-based system for a quantitative determination of the Bcc in an antacid oral suspension was studied. The main purpose of this validation study was to prove that the alternative method's entire performance is not inferior to the conventional method for a quantitative determination of Bcc.</p><p><strong>Method: </strong>The antacid oral suspension's preservatives were neutralized, leading to the Burkholderia complex's recovery by means of the alternative method and the reference method. A calibration curve was generated for each strain by plotting DTs relative to the corresponding log CFU values. An equivalence of results was done through the construction of calibration curves that allowed the establishment of numerically equivalent results between the enumeration data from the reference method and the alternative method.</p><p><strong>Results: </strong>Thus following the guidelines of USP, essential validation parameters were shown, such as equivalence of results (CC >0.95), linearity (R2 >0.9025), accuracy (% recovery >70%), operating range, precision and ruggedness (DS <5 and CV <35%), specificity (inclusivity and exclusivity), limit of detection (LOD), and limit of quantification (LOQ).</p><p><strong>Conclusions: </strong>It was shown that all the test results obtained from the alternative method were in statistical agreement with the standard method. Thus this new technology was found to meet all the validation criteria needed to be considered as an alternative method for the quantification of the Burkholderia complex in the antacid oral suspension tested.</p><p><strong>Highlights: </strong>As outlined in USP chapter <1223> and demonstrated in this research the implementation of alternative methods can offer benefits in execution and automation while improving accuracy, sensitivity, and precision and can reduce the microbiological process time compared to the traditional ones.</p>","PeriodicalId":15003,"journal":{"name":"Journal of AOAC International","volume":"106 5","pages":"1288-1294"},"PeriodicalIF":1.7000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsad056","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1
Abstract
Background: Despite the broad adoption of Soleris® technology in the food industry as semiquantitative method, it is almost completely unexplored in the pharmaceutical industry as a quantitative method for quantification of Burkholderia cepacia complex (Bcc).
Objective: The efficacy of an automated growth-based system for a quantitative determination of the Bcc in an antacid oral suspension was studied. The main purpose of this validation study was to prove that the alternative method's entire performance is not inferior to the conventional method for a quantitative determination of Bcc.
Method: The antacid oral suspension's preservatives were neutralized, leading to the Burkholderia complex's recovery by means of the alternative method and the reference method. A calibration curve was generated for each strain by plotting DTs relative to the corresponding log CFU values. An equivalence of results was done through the construction of calibration curves that allowed the establishment of numerically equivalent results between the enumeration data from the reference method and the alternative method.
Results: Thus following the guidelines of USP, essential validation parameters were shown, such as equivalence of results (CC >0.95), linearity (R2 >0.9025), accuracy (% recovery >70%), operating range, precision and ruggedness (DS <5 and CV <35%), specificity (inclusivity and exclusivity), limit of detection (LOD), and limit of quantification (LOQ).
Conclusions: It was shown that all the test results obtained from the alternative method were in statistical agreement with the standard method. Thus this new technology was found to meet all the validation criteria needed to be considered as an alternative method for the quantification of the Burkholderia complex in the antacid oral suspension tested.
Highlights: As outlined in USP chapter <1223> and demonstrated in this research the implementation of alternative methods can offer benefits in execution and automation while improving accuracy, sensitivity, and precision and can reduce the microbiological process time compared to the traditional ones.
期刊介绍:
The Journal of AOAC INTERNATIONAL publishes the latest in basic and applied research in analytical sciences related to foods, drugs, agriculture, the environment, and more. The Journal is the method researchers'' forum for exchanging information and keeping informed of new technology and techniques pertinent to regulatory agencies and regulated industries.