Trans-rectal ultrasound-guided hybrid intra-cavitary and interstitial brachytherapy in carcinoma cervix: A feasibility study from a tertiary cancer center in India.

IF 1.1 4区 医学 Q4 ONCOLOGY Journal of Contemporary Brachytherapy Pub Date : 2023-06-01 DOI:10.5114/jcb.2023.127816
Harjot Kaur Bajwa, Rohith Singareddy, Anil Kumar Talluri, Heena Kauser, Devender Reddy Boja, G Srikanth, Alluri Krishnam Raju, Nvn Madhusudhana Sresty, Vyshnavi Mytri
{"title":"Trans-rectal ultrasound-guided hybrid intra-cavitary and interstitial brachytherapy in carcinoma cervix: A feasibility study from a tertiary cancer center in India.","authors":"Harjot Kaur Bajwa,&nbsp;Rohith Singareddy,&nbsp;Anil Kumar Talluri,&nbsp;Heena Kauser,&nbsp;Devender Reddy Boja,&nbsp;G Srikanth,&nbsp;Alluri Krishnam Raju,&nbsp;Nvn Madhusudhana Sresty,&nbsp;Vyshnavi Mytri","doi":"10.5114/jcb.2023.127816","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To report the feasibility of performing hybrid intra-cavitary and interstitial (IC/IS) brachytherapy in patients with carcinoma cervix under trans-rectal ultrasound (TRUS) guidance.</p><p><strong>Material and methods: </strong>All patients who received an external beam radiotherapy (EBRT) dose of 50 Gy in 25 fractions with weekly chemotherapy, followed by a brachytherapy boost (21 Gy in 3 fractions) were prospectively included for analysis. IC/IS brachytherapy was performed using Fletcher style tandem and ovoid applicator with interstitial component under TRUS guidance. Parameters of implant quality analyzed included ability to insert tandem, ratio of needles loaded to the number of needles inserted, and incidence of uterine or organ at risk (OARs) perforation. Dosimetric parameters evaluated were dose to point A*, TRAK, D<sub>90</sub> high-risk clinical target volume (HR-CTV), and D<sub>2cc</sub> to OARs (bladder, rectum, and sigmoid). Width and thickness of the target was compared between TRUS (TRUS<sub>w</sub> and TRUS<sub>t</sub>) and MRI (MRI<sub>w</sub> and MRI<sub>t</sub>).</p><p><strong>Results: </strong>Twenty carcinoma cervix patients treated with IC/IS brachytherapy were included for analysis. The mean HR-CTV volume was 36 cc. The median number of needles used were 6 (range, 2-10 needles). None of the patients had uterine perforation. Two patients had bowel and bladder perforation. The mean D<sub>90</sub> HR-CTV and D<sub>98</sub> HR-CTV were 87.3 Gy and 82 Gy EQD<sub>2</sub>, respectively. The mean D<sub>2cc</sub> to the bladder, rectum, and sigmoid were 80 Gy, 70 Gy, and 64 Gy EQD<sub>2</sub>, respectively. The mean dose to point A* was 70.4 Gy EQD<sub>2</sub>. The mean TRAK was 0.40. The mean TRUS<sub>w</sub> (±SD) and MRI<sub>w</sub> (±SD) were 4.58 cm (±0.44) and 4.49 cm (±0.50), respectively. The mean TRUS<sub>t</sub> (±SD) and MRI<sub>t</sub> (±SD) were 2.7 cm (±0.59) and 2.62 cm (±0.59), respectively. On statistical analysis, there was a significant correlation between TRUS<sub>w</sub> and MRI<sub>w</sub> (<i>r</i> = 0.93), and TRUS<sub>t</sub> and MRI<sub>t</sub> (<i>r</i> = 0.98).</p><p><strong>Conclusions: </strong>TRUS-guided IC/IS brachytherapy is feasible and provides adequate coverage of the target, with acceptable doses to OARs.</p>","PeriodicalId":51305,"journal":{"name":"Journal of Contemporary Brachytherapy","volume":"15 3","pages":"198-205"},"PeriodicalIF":1.1000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9d/ff/JCB-15-50779.PMC10324591.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Brachytherapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/jcb.2023.127816","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To report the feasibility of performing hybrid intra-cavitary and interstitial (IC/IS) brachytherapy in patients with carcinoma cervix under trans-rectal ultrasound (TRUS) guidance.

Material and methods: All patients who received an external beam radiotherapy (EBRT) dose of 50 Gy in 25 fractions with weekly chemotherapy, followed by a brachytherapy boost (21 Gy in 3 fractions) were prospectively included for analysis. IC/IS brachytherapy was performed using Fletcher style tandem and ovoid applicator with interstitial component under TRUS guidance. Parameters of implant quality analyzed included ability to insert tandem, ratio of needles loaded to the number of needles inserted, and incidence of uterine or organ at risk (OARs) perforation. Dosimetric parameters evaluated were dose to point A*, TRAK, D90 high-risk clinical target volume (HR-CTV), and D2cc to OARs (bladder, rectum, and sigmoid). Width and thickness of the target was compared between TRUS (TRUSw and TRUSt) and MRI (MRIw and MRIt).

Results: Twenty carcinoma cervix patients treated with IC/IS brachytherapy were included for analysis. The mean HR-CTV volume was 36 cc. The median number of needles used were 6 (range, 2-10 needles). None of the patients had uterine perforation. Two patients had bowel and bladder perforation. The mean D90 HR-CTV and D98 HR-CTV were 87.3 Gy and 82 Gy EQD2, respectively. The mean D2cc to the bladder, rectum, and sigmoid were 80 Gy, 70 Gy, and 64 Gy EQD2, respectively. The mean dose to point A* was 70.4 Gy EQD2. The mean TRAK was 0.40. The mean TRUSw (±SD) and MRIw (±SD) were 4.58 cm (±0.44) and 4.49 cm (±0.50), respectively. The mean TRUSt (±SD) and MRIt (±SD) were 2.7 cm (±0.59) and 2.62 cm (±0.59), respectively. On statistical analysis, there was a significant correlation between TRUSw and MRIw (r = 0.93), and TRUSt and MRIt (r = 0.98).

Conclusions: TRUS-guided IC/IS brachytherapy is feasible and provides adequate coverage of the target, with acceptable doses to OARs.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经直肠超声引导的腔内腔间混合近距离治疗宫颈癌:印度三级癌症中心的可行性研究。
目的:报道经直肠超声(TRUS)引导下对宫颈癌患者行腔内与间质混合近距离放射治疗的可行性。材料和方法:所有接受外束放疗(EBRT)剂量为50 Gy,分25次,每周化疗,随后接受近距离强化治疗(21 Gy,分3次)的患者前瞻性纳入分析。在TRUS引导下,使用Fletcher式串联和带有间质成分的卵形涂抹器进行IC/IS近距离治疗。植入物质量的分析参数包括串联插入的能力、负载针与插入针数的比例、子宫或危险器官穿孔的发生率。评估的剂量学参数为A点剂量、TRAK、D90高危临床靶体积(HR-CTV)和D2cc到OARs(膀胱、直肠和乙状结肠)。比较TRUS (TRUSw和TRUSt)和MRI (MRIw和MRIt)对靶区宽度和厚度的影响。结果:纳入20例接受IC/IS近距离放疗的宫颈癌患者。HR-CTV平均容积为36cc,中位针数为6根(范围2-10根)。所有患者均无子宫穿孔。2例患者有肠道和膀胱穿孔。平均D90 HR-CTV为87.3 Gy, D98 HR-CTV为82 Gy EQD2。膀胱、直肠和乙状结肠的平均D2cc分别为80 Gy、70 Gy和64 Gy。到A*点的平均剂量为70.4 Gy EQD2。平均TRAK为0.40。平均TRUSw(±SD)和MRIw(±SD)分别为4.58 cm(±0.44)和4.49 cm(±0.50)。平均TRUSt(±SD)和MRIt(±SD)分别为2.7 cm(±0.59)和2.62 cm(±0.59)。经统计分析,TRUSw与mrriw (r = 0.93)、TRUSt与MRIt (r = 0.98)有显著相关。结论:trus引导下的IC/IS近距离治疗是可行的,并且在OARs可接受的剂量下提供足够的靶标覆盖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Contemporary Brachytherapy
Journal of Contemporary Brachytherapy ONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
2.40
自引率
14.30%
发文量
54
审稿时长
16 weeks
期刊介绍: The “Journal of Contemporary Brachytherapy” is an international and multidisciplinary journal that will publish papers of original research as well as reviews of articles. Main subjects of the journal include: clinical brachytherapy, combined modality treatment, advances in radiobiology, hyperthermia and tumour biology, as well as physical aspects relevant to brachytherapy, particularly in the field of imaging, dosimetry and radiation therapy planning. Original contributions will include experimental studies of combined modality treatment, tumor sensitization and normal tissue protection, molecular radiation biology, and clinical investigations of cancer treatment in brachytherapy. Another field of interest will be the educational part of the journal.
期刊最新文献
The role of EUS-guided iodine-125 seed implantation in patients with unresectable ampullary cancer after relief of obstructive jaundice Acute toxicity outcomes from salvage high-dose-rate brachytherapy for locally recurrent prostate cancer after prior radiotherapy Differential outcomes of re-stratified high-risk prostate cancer patients treated with external beam radiation therapy plus high-dose-rate brachytherapy boost A unified strategy to focal brachytherapy incorporating transperineal biopsy, image fusion, and real-time implantation with and without rectal spacer simulated in prostate phantoms Post-operative complications following dose adaptation of intra-operative electron beam radiation therapy in locally advanced or recurrent rectal cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1