The test-retest reliability and minimal detectable change of the six-minute walk test, timed up and go test, and 30-second chair stand test in people with epilepsy.
Burcin Aktar, Birgul Balci, Ibrahim Oztura, Baris Baklan
{"title":"The test-retest reliability and minimal detectable change of the six-minute walk test, timed up and go test, and 30-second chair stand test in people with epilepsy.","authors":"Burcin Aktar, Birgul Balci, Ibrahim Oztura, Baris Baklan","doi":"10.1080/09593985.2023.2237566","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The available evidence suggests that people with epilepsy have reduced cardio-respiratory fitness and muscle strength endurance, and impaired balance and mobility. The 6-minute walk test (6MWT), Timed Up and Go (TUG), and 30-second chair stand test (30CST) are physical performance tests frequently used in clinical practice.</p><p><strong>Objective: </strong>To establish the test-retest reliability and minimal detectable change of the 6MWT, TUG, and 30CST in people with epilepsy.</p><p><strong>Methods: </strong>The study was designed as an observational study. Forty-one people with epilepsy (23 females, 18 males; mean age 34.7 ± 10.4 years) participated. The 6MWT, TUG, and 30CST were tested by a trained physiotherapist during two sessions, which were conducted 7-14 days apart. The test-retest reliability of measures was assessed using the intra-class correlation coefficients (ICC) using two-way random effects and absolute agreement methods. The 95% limits of agreement, standard error of measurement (SEM), and minimal detectable change (MDC₉₅) were calculated.</p><p><strong>Results: </strong>The 6MWT (ICC = 0.92, SEM = 15.8, MDC₉₅ = 43.8), TUG (ICC = 0.95, SEM = 3.2, MDC₉₅ = 0.5) and 30CST (ICC = 0.92, SEM = 1.0, MDC₉₅ = 2.8) performance measurements demonstrated excellent test-retest reliability. The 95% limits of agreement was calculated, as illustrated in a Bland-Altman plot.</p><p><strong>Conclusion: </strong>The 6MWT, TUG, and 30CST are reliable for measuring physical performance. The findings of this study can support researchers and clinicians to decide if a change score of a person with epilepsy is likely to be measurement error or true change.</p>","PeriodicalId":48699,"journal":{"name":"Physiotherapy Theory and Practice","volume":" ","pages":"2298-2407"},"PeriodicalIF":1.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiotherapy Theory and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09593985.2023.2237566","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The available evidence suggests that people with epilepsy have reduced cardio-respiratory fitness and muscle strength endurance, and impaired balance and mobility. The 6-minute walk test (6MWT), Timed Up and Go (TUG), and 30-second chair stand test (30CST) are physical performance tests frequently used in clinical practice.
Objective: To establish the test-retest reliability and minimal detectable change of the 6MWT, TUG, and 30CST in people with epilepsy.
Methods: The study was designed as an observational study. Forty-one people with epilepsy (23 females, 18 males; mean age 34.7 ± 10.4 years) participated. The 6MWT, TUG, and 30CST were tested by a trained physiotherapist during two sessions, which were conducted 7-14 days apart. The test-retest reliability of measures was assessed using the intra-class correlation coefficients (ICC) using two-way random effects and absolute agreement methods. The 95% limits of agreement, standard error of measurement (SEM), and minimal detectable change (MDC₉₅) were calculated.
Results: The 6MWT (ICC = 0.92, SEM = 15.8, MDC₉₅ = 43.8), TUG (ICC = 0.95, SEM = 3.2, MDC₉₅ = 0.5) and 30CST (ICC = 0.92, SEM = 1.0, MDC₉₅ = 2.8) performance measurements demonstrated excellent test-retest reliability. The 95% limits of agreement was calculated, as illustrated in a Bland-Altman plot.
Conclusion: The 6MWT, TUG, and 30CST are reliable for measuring physical performance. The findings of this study can support researchers and clinicians to decide if a change score of a person with epilepsy is likely to be measurement error or true change.
期刊介绍:
The aim of Physiotherapy Theory and Practice is to provide an international, peer-reviewed forum for the publication, dissemination, and discussion of recent developments and current research in physiotherapy/physical therapy. The journal accepts original quantitative and qualitative research reports, theoretical papers, systematic literature reviews, clinical case reports, and technical clinical notes. Physiotherapy Theory and Practice; promotes post-basic education through reports, reviews, and updates on all aspects of physiotherapy and specialties relating to clinical physiotherapy.