The influence of patient position on ultrasound examination of the sciatic nerve in the popliteal fossa: A cross-sectional study

Ron E. Samet, Nicolas Dorsey, Joshua W. Sappenfield, Andrew K. Gold, Emily J. Hsiao, Soren M. Bentzen, Paul E. Bigeleisen
{"title":"The influence of patient position on ultrasound examination of the sciatic nerve in the popliteal fossa: A cross-sectional study","authors":"Ron E. Samet,&nbsp;Nicolas Dorsey,&nbsp;Joshua W. Sappenfield,&nbsp;Andrew K. Gold,&nbsp;Emily J. Hsiao,&nbsp;Soren M. Bentzen,&nbsp;Paul E. Bigeleisen","doi":"10.1002/ajum.12342","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction/Purpose</h3>\n \n <p>Ultrasound-guided popliteal fossa sciatic nerve (PFSN) blocks are performed with patients in the supine, lateral or prone position. No known studies compare the quality of images obtained from each approach. This study examines the quality of supine and prone PFSN ultrasound images.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Thirty-eight adult volunteers were sorted into two groups. Five regional anaesthesiologists performed ultrasound examinations of the PFSN on volunteers in supine and prone positions. Popliteal fossa sciatic nerve image quality was analysed with grayscale techniques and peer evaluation. Popliteal fossa sciatic nerve depth, distance from the popliteal crease and time until optimal imaging were recorded.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The grayscale ratio of the PFSN vs. the background was 1.83 (supine) and 1.75 (prone) (P = 0.034). Similarly, the grayscale ratio of the PFSN vs. the immediately adjacent area was 1.65 (supine) and 1.55 (prone) (P = 0.004). Mean depth of the PFSN was 1.6 cm (supine) and 1.7 cm (prone) (P = 0.009). Average distance from the popliteal crease to the PFSN was 5.9 cm (supine) and 6.6 cm (prone) (P = 0.02). Mean time to acquire optimal imaging was 36 s (supine) and 47 s (prone) (P = 0.002). Observers preferred supine positioning 53.8%, prone positioning 22.5% and no preference 23.7% of the time. Observers with strong preferences preferred supine imaging in 70.9% of cases.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Supine ultrasound examination offered quicker identification of the PFSN, in a more superficial location, closer to the popliteal crease and with enhanced contrast to surrounding tissue, correlating with observer preferences for supine positioning. These results may influence ultrasound-guided PFSN block success rates, especially in difficult-to-image patients.</p>\n </section>\n </div>","PeriodicalId":36517,"journal":{"name":"Australasian Journal of Ultrasound in Medicine","volume":"26 3","pages":"142-149"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ajum.12342","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australasian Journal of Ultrasound in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ajum.12342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

Abstract

Introduction/Purpose

Ultrasound-guided popliteal fossa sciatic nerve (PFSN) blocks are performed with patients in the supine, lateral or prone position. No known studies compare the quality of images obtained from each approach. This study examines the quality of supine and prone PFSN ultrasound images.

Methods

Thirty-eight adult volunteers were sorted into two groups. Five regional anaesthesiologists performed ultrasound examinations of the PFSN on volunteers in supine and prone positions. Popliteal fossa sciatic nerve image quality was analysed with grayscale techniques and peer evaluation. Popliteal fossa sciatic nerve depth, distance from the popliteal crease and time until optimal imaging were recorded.

Results

The grayscale ratio of the PFSN vs. the background was 1.83 (supine) and 1.75 (prone) (P = 0.034). Similarly, the grayscale ratio of the PFSN vs. the immediately adjacent area was 1.65 (supine) and 1.55 (prone) (P = 0.004). Mean depth of the PFSN was 1.6 cm (supine) and 1.7 cm (prone) (P = 0.009). Average distance from the popliteal crease to the PFSN was 5.9 cm (supine) and 6.6 cm (prone) (P = 0.02). Mean time to acquire optimal imaging was 36 s (supine) and 47 s (prone) (P = 0.002). Observers preferred supine positioning 53.8%, prone positioning 22.5% and no preference 23.7% of the time. Observers with strong preferences preferred supine imaging in 70.9% of cases.

Conclusions

Supine ultrasound examination offered quicker identification of the PFSN, in a more superficial location, closer to the popliteal crease and with enhanced contrast to surrounding tissue, correlating with observer preferences for supine positioning. These results may influence ultrasound-guided PFSN block success rates, especially in difficult-to-image patients.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
病人体位对腘窝坐骨神经超声检查的影响:一项横断面研究
超声引导的腘窝坐骨神经(PFSN)阻滞适用于仰卧位、侧卧位或俯卧位的患者。没有已知的研究比较从每种方法获得的图像质量。本研究探讨了仰卧位和俯卧位PFSN超声图像的质量。方法38名成年志愿者分为两组。5名区域麻醉师对仰卧位和俯卧位的志愿者进行PFSN超声检查。采用灰度技术和同行评价对腘窝坐骨神经图像质量进行分析。记录腘窝坐骨神经深度、距腘窝折痕的距离及到达最佳成像时间。结果PFSN与背景的灰度比(仰卧位)为1.83,俯卧位为1.75 (P = 0.034)。同样,PFSN与紧邻区域的灰度比为1.65(仰卧位)和1.55(俯卧位)(P = 0.004)。PFSN平均深度为1.6 cm(仰卧位)和1.7 cm(俯卧位)(P = 0.009)。从腘窝沟到PFSN的平均距离为5.9 cm(仰卧位)和6.6 cm(俯卧位)(P = 0.02)。获得最佳成像的平均时间为仰卧位36 s,俯卧位47 s (P = 0.002)。53.8%的观测者选择仰卧位,22.5%的观测者选择俯卧位,23.7%的观测者不选择仰卧位。有强烈偏好的观察者在70.9%的病例中更倾向于仰卧位成像。结论仰卧位超声检查可以更快地识别PFSN,其位置更浅表,更靠近腘窝折痕,与周围组织的对比增强,与观察者对仰卧位的偏好有关。这些结果可能会影响超声引导下PFSN阻滞的成功率,特别是在难以成像的患者中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Australasian Journal of Ultrasound in Medicine
Australasian Journal of Ultrasound in Medicine Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.90
自引率
0.00%
发文量
40
期刊最新文献
Issue Information The impact of ultrasound imaging on patient management – Let's practice the evidence EUS‐guided tissue acquisition from gastric subepithelial lesions—The optimal technique still remains undecided Ultrasound‐assisted and landmark‐based nusinersen delivery in spinal muscular atrophy adults: A retrospective analysis Cutaneous ultrasound in the diagnosis and assessment of inflammatory activity in tinea capitis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1