{"title":"Three-dimensional evaluation of microvascular networks using contrast-enhanced ultrasound and microbubble tracking.","authors":"Kenneth Johnson, Ipek Oezdemir, Kenneth Hoyt","doi":"10.1109/ius46767.2020.9251525","DOIUrl":null,"url":null,"abstract":"<p><p>Evaluating tumor microvascular networks with use of contrast-enhanced ultrasound (CEUS) imaging and one-dimensional (1D) linear array transducers have inherit limitations as tumors exist in volume space. The use of a mechanical sweep allows users to overcome this limitation. To that end, we have developed a new method by which a 1D linear array transducer can be mechanically scanned over a region-of-interest to capture a volume of data allowing for the evaluation of microvasculature structures in 3D space. After intravascular injection of a microbubble (MB) contrast agent into a developing chicken embryo, a sequence of CEUS images were acquired using a Vevo 3100 scanner (VisualSonics Inc) and taken at multiple tissue cross-sections. The CEUS images were processed with a singular value filter (SVF) to help remove any clutter signal. MB localization was performed, and frame-to-frame MB movement was analyzed to produce spatial maps depicting blood flow and velocity at each tissue cross-section. Reconstruction of all images allowed visualization of microvascular networks and blood velocity distribution in volume space.</p>","PeriodicalId":73288,"journal":{"name":"IEEE International Ultrasonics Symposium : [proceedings]. IEEE International Ultrasonics Symposium","volume":"2020 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9728804/pdf/nihms-1846149.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Ultrasonics Symposium : [proceedings]. IEEE International Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ius46767.2020.9251525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Evaluating tumor microvascular networks with use of contrast-enhanced ultrasound (CEUS) imaging and one-dimensional (1D) linear array transducers have inherit limitations as tumors exist in volume space. The use of a mechanical sweep allows users to overcome this limitation. To that end, we have developed a new method by which a 1D linear array transducer can be mechanically scanned over a region-of-interest to capture a volume of data allowing for the evaluation of microvasculature structures in 3D space. After intravascular injection of a microbubble (MB) contrast agent into a developing chicken embryo, a sequence of CEUS images were acquired using a Vevo 3100 scanner (VisualSonics Inc) and taken at multiple tissue cross-sections. The CEUS images were processed with a singular value filter (SVF) to help remove any clutter signal. MB localization was performed, and frame-to-frame MB movement was analyzed to produce spatial maps depicting blood flow and velocity at each tissue cross-section. Reconstruction of all images allowed visualization of microvascular networks and blood velocity distribution in volume space.