Abutment removal torque and implant conical surface morphological changes after standardized artificial aging: An in vitro study

IF 4.8 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2024-11-01 DOI:10.1016/j.prosdent.2022.11.016
Zhihao Zhai DDS, PhD , Tamaki Nakano DDS, PhD , Yuming Chen DDS , Shota Watanabe DDS, PhD , Takashi Matsuoka DDS, PhD , Shoichi Ishigaki DDS, PhD
{"title":"Abutment removal torque and implant conical surface morphological changes after standardized artificial aging: An in vitro study","authors":"Zhihao Zhai DDS, PhD ,&nbsp;Tamaki Nakano DDS, PhD ,&nbsp;Yuming Chen DDS ,&nbsp;Shota Watanabe DDS, PhD ,&nbsp;Takashi Matsuoka DDS, PhD ,&nbsp;Shoichi Ishigaki DDS, PhD","doi":"10.1016/j.prosdent.2022.11.016","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div><span>Zirconia </span>abutments have become popular as they provide favorable esthetic outcomes. However, studies investigating how abutment material affects abutment screw torque performance and implant conical surface morphological changes in internal conical connection systems are scarce.</div></div><div><h3>Purpose</h3><div>The purpose of this in vitro study was to investigate the influence of abutment material on abutment removal torque and implant conical surface morphological changes in internal conical connection implant–abutment assemblies of 2 diameters after simulated long-term oral use.</div></div><div><h3>Material and methods</h3><div><span><span>Thirty abutments of 3 materials (1-piece titanium, 1-piece zirconia, zirconia with alloy base) and 2 diameters (regular, narrow) made by the original manufacturer were connected to internal conical connection implants and subjected to a standardized artificial aging process consisting of thermal cycling and mechanical cyclic loading with parameters corresponding to anterior and posterior </span>mastication<span> scenarios simulating long-term oral use. An abutment removal torque test was done before and after aging. Morphological changes in the implant conical contact surface were observed with a scanning electron microscope (SEM). Initial and after-aging torque loss values were calculated and analyzed separately with 1-way ANOVA and Tukey HSD </span></span>post hoc tests (α=.05).</div></div><div><h3>Results</h3><div>All specimens survived artificial aging. For initial and after-aging torque loss, the 1-piece zirconia groups showed significantly greater values (<em>P</em>&lt;.001) for both diameters. In the SEM observation, the 1-piece zirconia groups showed distinct widespread surface damage while the other groups exhibited only minor damages.</div></div><div><h3>Conclusions</h3><div>Regardless of diameter, 1-piece zirconia abutments tend to induce more abutment removal torque loss and implant conical surface morphological changes than those with metal connections, both initially and after simulated long-term oral use. Zirconia abutments with an alloy base performed similarly to 1-piece titanium abutments.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"132 5","pages":"Pages 1005-1013"},"PeriodicalIF":4.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391322007387","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

Zirconia abutments have become popular as they provide favorable esthetic outcomes. However, studies investigating how abutment material affects abutment screw torque performance and implant conical surface morphological changes in internal conical connection systems are scarce.

Purpose

The purpose of this in vitro study was to investigate the influence of abutment material on abutment removal torque and implant conical surface morphological changes in internal conical connection implant–abutment assemblies of 2 diameters after simulated long-term oral use.

Material and methods

Thirty abutments of 3 materials (1-piece titanium, 1-piece zirconia, zirconia with alloy base) and 2 diameters (regular, narrow) made by the original manufacturer were connected to internal conical connection implants and subjected to a standardized artificial aging process consisting of thermal cycling and mechanical cyclic loading with parameters corresponding to anterior and posterior mastication scenarios simulating long-term oral use. An abutment removal torque test was done before and after aging. Morphological changes in the implant conical contact surface were observed with a scanning electron microscope (SEM). Initial and after-aging torque loss values were calculated and analyzed separately with 1-way ANOVA and Tukey HSD post hoc tests (α=.05).

Results

All specimens survived artificial aging. For initial and after-aging torque loss, the 1-piece zirconia groups showed significantly greater values (P<.001) for both diameters. In the SEM observation, the 1-piece zirconia groups showed distinct widespread surface damage while the other groups exhibited only minor damages.

Conclusions

Regardless of diameter, 1-piece zirconia abutments tend to induce more abutment removal torque loss and implant conical surface morphological changes than those with metal connections, both initially and after simulated long-term oral use. Zirconia abutments with an alloy base performed similarly to 1-piece titanium abutments.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
标准化人工老化后的基台去除扭矩和种植体锥形表面形态变化:体外研究
问题陈述:氧化锆基台具有良好的美观效果,因此很受欢迎。目的:本体外研究的目的是探讨在模拟长期口腔使用后,基台材料对2种直径的内锥连接种植体-基台组件的基台拆卸扭矩和种植体锥面形态变化的影响:将原厂生产的3种材料(1片钛合金、1片氧化锆、合金基底氧化锆)、2种直径(常规直径、窄直径)的30个基台与内锥形连接种植体连接,并对其进行标准化的人工老化处理,包括热循环和机械循环加载,其参数与模拟长期口腔使用的前后咀嚼情景相对应。在老化前后都进行了基台移除扭矩测试。使用扫描电子显微镜(SEM)观察种植体锥形接触面的形态变化。计算初始扭矩损失值和老化后扭矩损失值,并分别进行单因素方差分析和 Tukey HSD 后检验(α=.05):结果:所有试样都经受住了人工老化。在初始扭矩损失和老化后扭矩损失方面,1 片氧化锆组的数值明显更大(PConclusions.No.1):无论直径大小,与金属连接的基台相比,单件式氧化锆基台在初期和模拟长期口腔使用后都会引起更多的基台移除扭矩损失和种植体锥形表面形态变化。带有合金基底的氧化锆基台与单件式钛基台的表现相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Do color stability and translucency differ between 3D printed and milled resin-based fixed dental restorations? A systematic review and meta-analysis. Dimensional accuracy and internal fit of anterior 3-unit fixed dental prostheses fabricated by additive and subtractive manufacturing using polymer-based and ceramic restorative materials. A systematic review and meta-analysis of the accuracy of complete arch implant scanning techniques performed extraorally: Reverse impression and extraoral photogrammetry methods. Report of the Committee on Research in Fixed Prosthodontics of the American Academy of Fixed Prosthodontics. Response to Letter to the Editor on the Manuscript, "Comparing the performance of ChatGPT 4o, DeepSeek R1, and Gemini 2 Pro in answering fixed prosthodontics questions over time". Effect of different surface treatments on the bond strength between light-polymerized hard chairside relining material and computer-aided design and computer-aided manufacturing (CAD-CAM) milled denture base materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1