Comparison of Microorganism Detection, Time to Positivity, and Time-Dependent Shift in Viable Bacterial Count from VersaTREK and BacT/ALERT 3D Blood Culture Systems.

Akihiro Nakamura, Osamu Ueda, Noriyuki Abe, Masashi Shimada, Mikio Kamioka, Masaru Komatsu
{"title":"Comparison of Microorganism Detection, Time to Positivity, and Time-Dependent Shift in Viable Bacterial Count from VersaTREK and BacT/ALERT 3D Blood Culture Systems.","authors":"Akihiro Nakamura,&nbsp;Osamu Ueda,&nbsp;Noriyuki Abe,&nbsp;Masashi Shimada,&nbsp;Mikio Kamioka,&nbsp;Masaru Komatsu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Rapid positive blood culture reporting allows early and appropriate treatment of severe infections to improve patient prognosis. This study evaluated performance of the VersaTREK system with gas pressure detection and tornado stirring method and the conventional BacT/ALERT 3D system. Time to positivity (TTP) of simulated blood cultures without whole blood using 17 ATCC strains was faster with VersaTREK than BacT/ALERT 3D, averaging 6.3 h in aerobic bottles and 12.7 hours in anaerobic bottles. In simulated blood cultures with whole blood using 53 clinical isolates, on average, VersaTREK was faster in aerobic bottles by 6.5 h but slower in anaerobic bottles by 3.8 h. Fifty of 53 simulated blood cultures with whole blood (94%) showed fastest TTP with VersaTREK. TTP of VersaTREK for anaerobic bacteria <i>Bacteroides fragilis</i> and <i>Clostridium perfringens</i>, <i>Helicobacter cinaedi</i>, and <i>Candida glabrata</i> was fast, and viable bacteria numbers in bottles using the Miles and Misra method increased quickly.</p>","PeriodicalId":74740,"journal":{"name":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","volume":"32 1","pages":"23-35"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Rapid positive blood culture reporting allows early and appropriate treatment of severe infections to improve patient prognosis. This study evaluated performance of the VersaTREK system with gas pressure detection and tornado stirring method and the conventional BacT/ALERT 3D system. Time to positivity (TTP) of simulated blood cultures without whole blood using 17 ATCC strains was faster with VersaTREK than BacT/ALERT 3D, averaging 6.3 h in aerobic bottles and 12.7 hours in anaerobic bottles. In simulated blood cultures with whole blood using 53 clinical isolates, on average, VersaTREK was faster in aerobic bottles by 6.5 h but slower in anaerobic bottles by 3.8 h. Fifty of 53 simulated blood cultures with whole blood (94%) showed fastest TTP with VersaTREK. TTP of VersaTREK for anaerobic bacteria Bacteroides fragilis and Clostridium perfringens, Helicobacter cinaedi, and Candida glabrata was fast, and viable bacteria numbers in bottles using the Miles and Misra method increased quickly.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
VersaTREK和BacT/ALERT 3D血液培养系统的微生物检测、阳性时间和活菌计数随时间变化的比较
快速血培养阳性报告可以早期和适当治疗严重感染,以改善患者预后。该研究评估了带有气体压力检测和龙卷风搅拌方法的VersaTREK系统与传统的BacT/ALERT 3D系统的性能。使用VersaTREK对17株ATCC菌株无全血模拟血培养的阳性时间(TTP)比BacT/ALERT 3D更快,好氧瓶平均为6.3 h,无氧瓶平均为12.7 h。在53个临床分离株全血模拟血培养中,VersaTREK在好氧瓶中平均快6.5小时,在无氧瓶中慢3.8小时。53个全血模拟血培养中有50个(94%)显示VersaTREK的TTP最快。VersaTREK对厌氧菌脆弱拟杆菌、产气荚膜梭菌、中国幽门螺杆菌、光假丝酵母TTP快,Miles法和Misra法瓶内活菌数增加快。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Japanese Case of COVID-19 Caused by Omicron Strain with Y453F Substitution. [Evaluation of Methicillin Resistance Determination Time for MRSA Using Fully Automated Rapid Identification Susceptibility testing system RAISAS S4]. [Evaluation of the Clinical Validity of the Clostridioides difficile Nucleic Acid Detection Kit "Smart Gene® CD ToxinB"]. [Relationship between Serotypes and Biotypes of Yersinia enterocolitica and the Names of Identified Bacteria in the Microbial Identification and Susceptibility Testing Devices]. Comparison of Microorganism Detection, Time to Positivity, and Time-Dependent Shift in Viable Bacterial Count from VersaTREK and BacT/ALERT 3D Blood Culture Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1