Field output correction factors of stereotactic cones for a diode detector: Dependence on cone size, measurement setup, reference field size and photon energy.
{"title":"Field output correction factors of stereotactic cones for a diode detector: Dependence on cone size, measurement setup, reference field size and photon energy.","authors":"Yongsook C Lee, Yongbok Kim","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated if field output correction factors (FOCFs) of Varian stereotactic cones for Edge detectorTM had dependence on cone size, measurement setup, reference field size and/or photon energy. Field output factors (FOFs) of stereotactic cones were measured at three depths (1.5 cm, 5 cm and 10 cm) in two different setups (source-to-surface distance (SSD) and source-to-axis distance (SAD)) with two photon energies (6 MV and 6 MV flattening filter free) using the Edge detector and Exradin<sub>®</sub> W2 scintillator. Two reference fields (10 × 10 cm<sup>2</sup> and 4 × 4 cm<sup>2</sup>) were chosen. FOCFs for the Edge detector were determined by calculating FOF<sub>W2</sub>/FOF<sub>Edge</sub> and compared among cones and between depths, setups, reference fields and energies. It is concluded that FOCFs for the Edge detector have dependence on cone size, SSD/SAD setup and energy for small cones, but do not have dependence on depth and reference field size.</p>","PeriodicalId":16917,"journal":{"name":"Journal of radiosurgery and SBRT","volume":"8 2","pages":"127-136"},"PeriodicalIF":0.7000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9489070/pdf/rsbrt-8-127.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of radiosurgery and SBRT","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
This study investigated if field output correction factors (FOCFs) of Varian stereotactic cones for Edge detectorTM had dependence on cone size, measurement setup, reference field size and/or photon energy. Field output factors (FOFs) of stereotactic cones were measured at three depths (1.5 cm, 5 cm and 10 cm) in two different setups (source-to-surface distance (SSD) and source-to-axis distance (SAD)) with two photon energies (6 MV and 6 MV flattening filter free) using the Edge detector and Exradin® W2 scintillator. Two reference fields (10 × 10 cm2 and 4 × 4 cm2) were chosen. FOCFs for the Edge detector were determined by calculating FOFW2/FOFEdge and compared among cones and between depths, setups, reference fields and energies. It is concluded that FOCFs for the Edge detector have dependence on cone size, SSD/SAD setup and energy for small cones, but do not have dependence on depth and reference field size.