Facilitating glaucoma diagnosis with intereye neuroretinal rim asymmetry analysis using spectral-domain optical coherence tomography.

Andrew S Taliaferro, Mahmoud A Fayed, Edem Tsikata, Regina A De Luna, Firas Jassim, Sumir Pandit, Elli A Park, Maria A Guzman Aparicio, Linda Yi-Chieh Poon, Christian Que, Huseyin Simavli, Vivek Srinivasan, Johannes F de Boer, Teresa C Chen
{"title":"Facilitating glaucoma diagnosis with intereye neuroretinal rim asymmetry analysis using spectral-domain optical coherence tomography.","authors":"Andrew S Taliaferro,&nbsp;Mahmoud A Fayed,&nbsp;Edem Tsikata,&nbsp;Regina A De Luna,&nbsp;Firas Jassim,&nbsp;Sumir Pandit,&nbsp;Elli A Park,&nbsp;Maria A Guzman Aparicio,&nbsp;Linda Yi-Chieh Poon,&nbsp;Christian Que,&nbsp;Huseyin Simavli,&nbsp;Vivek Srinivasan,&nbsp;Johannes F de Boer,&nbsp;Teresa C Chen","doi":"10.5693/djo.01.2022.10.001","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine whether intereye asymmetry of a three-dimensional neuroretinal rim parameter, the minimum distance band, is useful in differentiating normal eyes from those with open-angle glaucoma.</p><p><strong>Materials and methods: </strong>This is a cross-sectional study of 28 normal subjects and 33 glaucoma subjects. Subjects underwent spectral domain optical coherence tomography imaging of both eyes. From high-density raster scans of the optic nerve head, a custom-designed segmentation algorithm calculated mean minimum distance band neuroretinal rim thickness globally, for four quadrants, and for four sectors. Intereye minimum distance band thickness asymmetry was calculated as the absolute difference in minimum distance band thickness values between the right and left eyes.</p><p><strong>Results: </strong>Increasing global minimum distance band thickness asymmetry was not associated with increasing age or increasing refractive error asymmetry. Glaucoma patients had thinner mean neuroretinal rim thickness values compared to normal patients (209.0 μm vs 306.0 μm [<i>P</i> < 0.001]). Glaucoma subjects had greater intereye thickness asymmetry compared to normal subjects for the global region (51.9 μm vs 17.6 μm [<i>P</i> < 0.001]) as well as for all quadrants and all sectors. For detecting glaucoma, a thickness asymmetry value >28.3 μm in the inferior quadrant yielded the greatest sum of sensitivity (87.9%) and specificity (75.0%). Globally, thickness asymmetry >30.7 μm yielded the greatest sum of sensitivity (66.7%) and specificity (89.3%).</p><p><strong>Conclusions: </strong>This study indicates that intereye neuroretinal rim minimum distance band asymmetry measurements, using high-density spectral domain optical coherence tomography volume scans, may be an objective and quantitative tool for assessing patients suspected of open-angle glaucoma.</p>","PeriodicalId":38112,"journal":{"name":"Digital journal of ophthalmology : DJO","volume":"28 4","pages":"100-109"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9838176/pdf/djo-22-127.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digital journal of ophthalmology : DJO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5693/djo.01.2022.10.001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To determine whether intereye asymmetry of a three-dimensional neuroretinal rim parameter, the minimum distance band, is useful in differentiating normal eyes from those with open-angle glaucoma.

Materials and methods: This is a cross-sectional study of 28 normal subjects and 33 glaucoma subjects. Subjects underwent spectral domain optical coherence tomography imaging of both eyes. From high-density raster scans of the optic nerve head, a custom-designed segmentation algorithm calculated mean minimum distance band neuroretinal rim thickness globally, for four quadrants, and for four sectors. Intereye minimum distance band thickness asymmetry was calculated as the absolute difference in minimum distance band thickness values between the right and left eyes.

Results: Increasing global minimum distance band thickness asymmetry was not associated with increasing age or increasing refractive error asymmetry. Glaucoma patients had thinner mean neuroretinal rim thickness values compared to normal patients (209.0 μm vs 306.0 μm [P < 0.001]). Glaucoma subjects had greater intereye thickness asymmetry compared to normal subjects for the global region (51.9 μm vs 17.6 μm [P < 0.001]) as well as for all quadrants and all sectors. For detecting glaucoma, a thickness asymmetry value >28.3 μm in the inferior quadrant yielded the greatest sum of sensitivity (87.9%) and specificity (75.0%). Globally, thickness asymmetry >30.7 μm yielded the greatest sum of sensitivity (66.7%) and specificity (89.3%).

Conclusions: This study indicates that intereye neuroretinal rim minimum distance band asymmetry measurements, using high-density spectral domain optical coherence tomography volume scans, may be an objective and quantitative tool for assessing patients suspected of open-angle glaucoma.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用光谱域光学相干断层扫描对眼间神经视网膜边缘不对称分析进行青光眼诊断。
目的:探讨三维神经视网膜边缘参数(最小距离带)的眼间不对称性是否有助于正常眼与开角型青光眼的鉴别。材料与方法:对28例正常人和33例青光眼患者进行横断面研究。受试者进行了双眼光谱域光学相干断层成像。从视神经头部的高密度光栅扫描中,定制设计的分割算法计算了四个象限和四个扇区的平均最小距离带神经视网膜边缘厚度。眼间最小距离带厚度不对称性计算为左右眼最小距离带厚度值的绝对差值。结果:整体最小距离带厚度不对称性的增加与年龄的增加或屈光不对称性的增加无关。青光眼患者的神经视网膜边缘平均厚度较正常患者薄(209.0 μm vs 306.0 μm [P < 0.001])。青光眼受试者的眼间厚度不对称性在整个区域(51.9 μm vs 17.6 μm [P < 0.001])以及所有象限和所有扇区都比正常受试者更大。对于青光眼的检测,下象限厚度不对称值>28.3 μm时,灵敏度和特异度之和最高,分别为87.9%和75.0%。在全球范围内,厚度不对称>30.7 μm获得了最大的灵敏度(66.7%)和特异性(89.3%)。结论:本研究表明,采用高密度光谱域光学相干断层成像体积扫描测量眼间神经视网膜边缘最小距离带不对称性,可能是评估疑似开角型青光眼患者的客观定量工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Digital journal of ophthalmology : DJO
Digital journal of ophthalmology : DJO Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
14
期刊最新文献
Primary anaplastic extramedullary plasmacytoma in the lacrimal sac. A 22-year-old woman with alcoholic pancreatitis and bilateral central scotomata. Bilateral anterior lens capsule rupture in Alport syndrome: case series and literature review. Secondary glaucoma as a late complication of a primary iris stromal cyst. Excision of an intrascleral cyst guided by anterior segment optical coherence tomography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1