Comparison of artery diameters in the Aachen minipig serving as a human intracranial in vivo model.

IF 1.3 4区 农林科学 Q2 VETERINARY SCIENCES Laboratory Animals Pub Date : 2024-02-01 Epub Date: 2023-09-12 DOI:10.1177/00236772231169809
Christoph Dorn, Lara Bender, Thorsten Sichtermann, Jan Minkenberg, Maximilian Franko, Ehsan Yousefian, Martin Wiesmann, Andrea Stockero, Rebecca May, Hani Ridwan, Omid Nikoubashman, Christiane Franz
{"title":"Comparison of artery diameters in the Aachen minipig serving as a human intracranial in vivo model.","authors":"Christoph Dorn, Lara Bender, Thorsten Sichtermann, Jan Minkenberg, Maximilian Franko, Ehsan Yousefian, Martin Wiesmann, Andrea Stockero, Rebecca May, Hani Ridwan, Omid Nikoubashman, Christiane Franz","doi":"10.1177/00236772231169809","DOIUrl":null,"url":null,"abstract":"<p><p>Minipigs are used as in vivo endovascular models, particularly in stroke and aneurysm research. However, detailed knowledge of the diameters of forelimb arteries that are commonly used as surrogates for human brain-supplying arteries are lacking. This study aimed to determine the diameters of forelimb and neck arteries in Aachen minipigs and to compare those to the diameters of human cerebral brain-supplying arteries in order to assess the validity of the Aachen minipig as a human intracranial in vivo model. We measured the diameters in the external carotid artery and eight different branches of the subclavian artery in 12 Aachen minipigs using angiographic imaging. Analysed arteries comprised the external carotid artery, axillary artery, brachial artery, subscapular artery first segment, subscapular artery second segment, external thoracic artery, caudal circumflex humeral artery, suprascapular artery and thoracodorsal artery. We compared these diameters to diameters of the following human brain-supplying arteries: terminal internal carotid artery (carotid-T and petrous segment), M1 segment of the middle cerebral artery, M2 segments of the middle cerebral artery, anterior cerebral artery, vertebral artery and basilar artery. Median diameters of porcine forelimb arteries ranged from 1.8 to 4.9 mm, and human brain supplying arteries ranged in diameter from 1.4 to 4.3 mm. Depending on the intended use, this allows porcine forelimb arteries to be selected which are statistically comparable to human brain-supplying vessels. In conclusion, we identified several equivalent arteries of the porcine subclavian branches that are comparable to human brain-supplying arteries. This may help to validate the minipig as a suitable in vivo model for neurovascular experiments.</p>","PeriodicalId":18013,"journal":{"name":"Laboratory Animals","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Animals","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00236772231169809","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Minipigs are used as in vivo endovascular models, particularly in stroke and aneurysm research. However, detailed knowledge of the diameters of forelimb arteries that are commonly used as surrogates for human brain-supplying arteries are lacking. This study aimed to determine the diameters of forelimb and neck arteries in Aachen minipigs and to compare those to the diameters of human cerebral brain-supplying arteries in order to assess the validity of the Aachen minipig as a human intracranial in vivo model. We measured the diameters in the external carotid artery and eight different branches of the subclavian artery in 12 Aachen minipigs using angiographic imaging. Analysed arteries comprised the external carotid artery, axillary artery, brachial artery, subscapular artery first segment, subscapular artery second segment, external thoracic artery, caudal circumflex humeral artery, suprascapular artery and thoracodorsal artery. We compared these diameters to diameters of the following human brain-supplying arteries: terminal internal carotid artery (carotid-T and petrous segment), M1 segment of the middle cerebral artery, M2 segments of the middle cerebral artery, anterior cerebral artery, vertebral artery and basilar artery. Median diameters of porcine forelimb arteries ranged from 1.8 to 4.9 mm, and human brain supplying arteries ranged in diameter from 1.4 to 4.3 mm. Depending on the intended use, this allows porcine forelimb arteries to be selected which are statistically comparable to human brain-supplying vessels. In conclusion, we identified several equivalent arteries of the porcine subclavian branches that are comparable to human brain-supplying arteries. This may help to validate the minipig as a suitable in vivo model for neurovascular experiments.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比较作为人类颅内活体模型的亚琛小型猪的动脉直径。
迷你猪被用作体内血管内模型,尤其是在中风和动脉瘤研究中。然而,人们对通常用作人类脑供血动脉替代物的前肢动脉的直径缺乏详细了解。本研究旨在确定亚琛小型猪前肢和颈部动脉的直径,并将其与人类大脑供血动脉的直径进行比较,以评估亚琛小型猪作为人类颅内活体模型的有效性。我们利用血管成像技术测量了 12 只亚琛小型猪的颈外动脉和锁骨下动脉 8 个不同分支的直径。分析的动脉包括颈外动脉、腋动脉、肱动脉、肩胛下动脉第一段、肩胛下动脉第二段、胸外动脉、肱骨尾周动脉、肩胛上动脉和胸背动脉。我们将这些直径与以下人脑供血动脉的直径进行了比较:颈内动脉末端(颈内动脉 T 段和皮质段)、大脑中动脉 M1 段、大脑中动脉 M2 段、大脑前动脉、椎动脉和基底动脉。猪前肢动脉的中位直径从 1.8 毫米到 4.9 毫米不等,人脑供血动脉的直径从 1.4 毫米到 4.3 毫米不等。根据用途的不同,猪前肢动脉在统计学上可与人脑供血血管相媲美。总之,我们确定了猪锁骨下分支的几条等效动脉,它们与人脑供血动脉具有可比性。这可能有助于验证小型猪是否适合作为神经血管实验的体内模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Laboratory Animals
Laboratory Animals 生物-动物学
CiteScore
4.90
自引率
8.30%
发文量
64
审稿时长
6-12 weeks
期刊介绍: The international journal of laboratory animal science and welfare, Laboratory Animals publishes peer-reviewed original papers and reviews on all aspects of the use of animals in biomedical research. The journal promotes improvements in the welfare or well-being of the animals used, it particularly focuses on research that reduces the number of animals used or which replaces animal models with in vitro alternatives.
期刊最新文献
Half the price, twice the gain: How to simultaneously decrease animal numbers and increase precision with good experimental design. Heterogeneity of animal experiments and how to deal with it. How cage effects can hurt statistical analyses of completely randomized designs. Simulation methodologies to determine statistical power in laboratory animal research studies. Understanding p-values and significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1