Kathryn P. Burdon, Patricia Graham, Johanna Hadler, John D. Hulleman, Francesca Pasutto, Erin A. Boese, Jamie E. Craig, John H. Fingert, Alex W. Hewitt, Owen M. Siggs, Kristina Whisenhunt, Terri L. Young, David A. Mackey, Andrew Dubowsky, Emmanuelle Souzeau
{"title":"Specifications of the ACMG/AMP variant curation guidelines for myocilin: Recommendations from the clingen glaucoma expert panel","authors":"Kathryn P. Burdon, Patricia Graham, Johanna Hadler, John D. Hulleman, Francesca Pasutto, Erin A. Boese, Jamie E. Craig, John H. Fingert, Alex W. Hewitt, Owen M. Siggs, Kristina Whisenhunt, Terri L. Young, David A. Mackey, Andrew Dubowsky, Emmanuelle Souzeau","doi":"10.1002/humu.24482","DOIUrl":null,"url":null,"abstract":"<p>The standardization of variant curation criteria is essential for accurate interpretation of genetic results and clinical care of patients. The variant curation guidelines developed by the American College of Medical Genetics and Genomics (ACMG) and the Association for Molecular Pathology (AMP) in 2015 are widely used but are not gene specific. To address this issue, the Clinical Genome Resource (ClinGen) Variant Curation Expert Panels (VCEP) have been tasked with developing gene-specific variant curation guidelines. The Glaucoma VCEP was created to develop rule specifications for genes associated with primary glaucoma, including <i>myocilin</i> (<i>MYOC</i>), the most common cause of Mendelian glaucoma. Of the 28 ACMG/AMP criteria, the Glaucoma VCEP adapted 15 rules to <i>MYOC</i> and determined 13 rules not applicable. Key specifications included determining minor allele frequency thresholds, developing an approach to counting probands and segregations, and reviewing functional assays. The rules were piloted on 81 variants and led to a change in classification in 40% of those that were classified in ClinVar, with functional evidence influencing the classification of 18 variants. The standardized variant curation guidelines for <i>MYOC</i> provide a framework for the consistent application of the rules between laboratories, to improve <i>MYOC</i> genetic testing in the management of glaucoma.</p>","PeriodicalId":13061,"journal":{"name":"Human Mutation","volume":"43 12","pages":"2170-2186"},"PeriodicalIF":3.3000,"publicationDate":"2022-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9771967/pdf/","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Human Mutation","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/humu.24482","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GENETICS & HEREDITY","Score":null,"Total":0}
引用次数: 10
Abstract
The standardization of variant curation criteria is essential for accurate interpretation of genetic results and clinical care of patients. The variant curation guidelines developed by the American College of Medical Genetics and Genomics (ACMG) and the Association for Molecular Pathology (AMP) in 2015 are widely used but are not gene specific. To address this issue, the Clinical Genome Resource (ClinGen) Variant Curation Expert Panels (VCEP) have been tasked with developing gene-specific variant curation guidelines. The Glaucoma VCEP was created to develop rule specifications for genes associated with primary glaucoma, including myocilin (MYOC), the most common cause of Mendelian glaucoma. Of the 28 ACMG/AMP criteria, the Glaucoma VCEP adapted 15 rules to MYOC and determined 13 rules not applicable. Key specifications included determining minor allele frequency thresholds, developing an approach to counting probands and segregations, and reviewing functional assays. The rules were piloted on 81 variants and led to a change in classification in 40% of those that were classified in ClinVar, with functional evidence influencing the classification of 18 variants. The standardized variant curation guidelines for MYOC provide a framework for the consistent application of the rules between laboratories, to improve MYOC genetic testing in the management of glaucoma.
期刊介绍:
Human Mutation is a peer-reviewed journal that offers publication of original Research Articles, Methods, Mutation Updates, Reviews, Database Articles, Rapid Communications, and Letters on broad aspects of mutation research in humans. Reports of novel DNA variations and their phenotypic consequences, reports of SNPs demonstrated as valuable for genomic analysis, descriptions of new molecular detection methods, and novel approaches to clinical diagnosis are welcomed. Novel reports of gene organization at the genomic level, reported in the context of mutation investigation, may be considered. The journal provides a unique forum for the exchange of ideas, methods, and applications of interest to molecular, human, and medical geneticists in academic, industrial, and clinical research settings worldwide.