Detailed intraocular pressure curve by telemetric tonometry with an implanted pressure sensor before and after PreserFlo® MicroShunt implantation: a case report.
Caroline Julia Gassel, Dimitar Nikolov Dzhelebov, Bogomil Voykov
{"title":"Detailed intraocular pressure curve by telemetric tonometry with an implanted pressure sensor before and after PreserFlo<sup>®</sup> MicroShunt implantation: a case report.","authors":"Caroline Julia Gassel, Dimitar Nikolov Dzhelebov, Bogomil Voykov","doi":"10.1177/25158414221149927","DOIUrl":null,"url":null,"abstract":"<p><p>Continuous control of intraocular pressure (IOP) is crucial to preventing long-term damage to the optic nerve in glaucoma. Recently, a novel telemetric IOP sensor (EYEMATE-IO™, Implandata Ophthalmic Products GmbH, Hannover, Germany) has been developed that continuously records IOP. The patient can read the IOP measurements wirelessly using a hand-held reading device. We present the case of a 70-year-old patient with primary open-angle glaucoma who had been implanted with an EYEMATE-IO™ and recently underwent minimally invasive bleb-filtering surgery with the PreserFlo<sup>®</sup> MicroShunt (Santen, Osaka, Japan). This case demonstrates both the benefits of continuous pressure measurement with EYEMATE-IO™ and the ability of the PreserFlo<sup>®</sup> MicroShunt to significantly reduce IOP fluctuations.</p>","PeriodicalId":23054,"journal":{"name":"Therapeutic Advances in Ophthalmology","volume":"15 ","pages":"25158414221149927"},"PeriodicalIF":2.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/de/e1/10.1177_25158414221149927.PMC9875318.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/25158414221149927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 1
Abstract
Continuous control of intraocular pressure (IOP) is crucial to preventing long-term damage to the optic nerve in glaucoma. Recently, a novel telemetric IOP sensor (EYEMATE-IO™, Implandata Ophthalmic Products GmbH, Hannover, Germany) has been developed that continuously records IOP. The patient can read the IOP measurements wirelessly using a hand-held reading device. We present the case of a 70-year-old patient with primary open-angle glaucoma who had been implanted with an EYEMATE-IO™ and recently underwent minimally invasive bleb-filtering surgery with the PreserFlo® MicroShunt (Santen, Osaka, Japan). This case demonstrates both the benefits of continuous pressure measurement with EYEMATE-IO™ and the ability of the PreserFlo® MicroShunt to significantly reduce IOP fluctuations.