Electromyography of the External Anal Sphincter during Micturition and Electrophysiological Bulbocavernosus Reflex in Healthy Spayed Female Canines.

IF 1.9 Q2 VETERINARY SCIENCES Veterinary Medicine International Pub Date : 2023-01-01 DOI:10.1155/2023/3822212
Nicha Mongkolrat, Areerath Akatvipat, Phitchaya Saenubol, Pachara Pornnimitara, Sukolrat Boonyayatra, Siam Tongprasert
{"title":"Electromyography of the External Anal Sphincter during Micturition and Electrophysiological Bulbocavernosus Reflex in Healthy Spayed Female Canines.","authors":"Nicha Mongkolrat,&nbsp;Areerath Akatvipat,&nbsp;Phitchaya Saenubol,&nbsp;Pachara Pornnimitara,&nbsp;Sukolrat Boonyayatra,&nbsp;Siam Tongprasert","doi":"10.1155/2023/3822212","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to find methods and interferences and illustrate the pattern of external anal sphincter (EAS) electromyography (EMG) during micturition and to determine reference intervals of electrophysiological bulbocavernosus reflex (EBCR) by using robust statistical methods in healthy spayed female canines. Ten healthy spayed female canines (no breed restriction) with a body weight of 11.3-18 kg were enrolled. EAS EMG during micturition and the EBCR test were performed under light general anesthesia. Altogether 25 out of 34 EAS EMG showed a similar pattern, including low-amplitude high-frequency bursting pattern before voiding, medium- or high-amplitude low-frequency bursting pattern at the beginning of voiding, oscillate medium- and/or high-amplitude low-frequency bursting with a low-amplitude high-frequency bursting pattern during voiding, and high-amplitude high-frequency bursting pattern at the end of voiding. An average of 100 consecutive stimulations of EBCR for one cycle were performed in each dog and another cycle was repeated to ensure reproducibility. The lower and upper limits of the reference interval of EBCR onset latency values and EBCR mean amplitude values were calculated using both standard and robust methods with untransformed and transformed Box-Cox data. The EBCR onset latency was between 13.85 and 27.44 milliseconds, whereas the EBCR mean baseline to peak amplitude was not transformed with Box-Cox transformation. All EBCR compound muscle action potentials started with a negative sharp wave, which tapers from the baseline in the upward direction, showing an upturned bell-shaped curve. In conclusion, this study was possibly the first to examine the method and provide the electrographic pattern of EAS EMG during micturition and reference intervals of EBCR onset latency in spayed female dogs, which may serve as baseline information to help veterinarians differentiate healthy from diseased dogs. Further studies should compare normal dogs and dogs with lower urinary tract abnormalities at different lesion locations.</p>","PeriodicalId":23503,"journal":{"name":"Veterinary Medicine International","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9902114/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Medicine International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/3822212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to find methods and interferences and illustrate the pattern of external anal sphincter (EAS) electromyography (EMG) during micturition and to determine reference intervals of electrophysiological bulbocavernosus reflex (EBCR) by using robust statistical methods in healthy spayed female canines. Ten healthy spayed female canines (no breed restriction) with a body weight of 11.3-18 kg were enrolled. EAS EMG during micturition and the EBCR test were performed under light general anesthesia. Altogether 25 out of 34 EAS EMG showed a similar pattern, including low-amplitude high-frequency bursting pattern before voiding, medium- or high-amplitude low-frequency bursting pattern at the beginning of voiding, oscillate medium- and/or high-amplitude low-frequency bursting with a low-amplitude high-frequency bursting pattern during voiding, and high-amplitude high-frequency bursting pattern at the end of voiding. An average of 100 consecutive stimulations of EBCR for one cycle were performed in each dog and another cycle was repeated to ensure reproducibility. The lower and upper limits of the reference interval of EBCR onset latency values and EBCR mean amplitude values were calculated using both standard and robust methods with untransformed and transformed Box-Cox data. The EBCR onset latency was between 13.85 and 27.44 milliseconds, whereas the EBCR mean baseline to peak amplitude was not transformed with Box-Cox transformation. All EBCR compound muscle action potentials started with a negative sharp wave, which tapers from the baseline in the upward direction, showing an upturned bell-shaped curve. In conclusion, this study was possibly the first to examine the method and provide the electrographic pattern of EAS EMG during micturition and reference intervals of EBCR onset latency in spayed female dogs, which may serve as baseline information to help veterinarians differentiate healthy from diseased dogs. Further studies should compare normal dogs and dogs with lower urinary tract abnormalities at different lesion locations.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
健康绝育雌犬排尿时肛门外括约肌肌电图及球海绵体反射电生理。
本研究旨在通过稳健的统计方法,寻找排尿过程中肛门外括约肌(EAS)肌电图(EMG)的干扰和模式,并确定电生理球海绵体反射(EBCR)的参考间隔。10只健康的雌性绝育犬(无品种限制),体重11.3-18 kg。在轻全身麻醉下进行排尿时EAS肌电图和EBCR试验。在34例EAS肌电图中,有25例表现出类似的模式,包括排尿前的低振幅高频爆破模式、排尿开始时的中或高振幅低频爆破模式、排尿过程中振荡的中或高振幅低频爆破模式和低振幅高频爆破模式,以及排尿结束时的高振幅高频爆破模式。每只狗在一个周期内平均连续刺激EBCR 100次,并重复另一个周期以确保可重复性。利用未变换和变换后的Box-Cox数据,分别采用标准和鲁棒方法计算EBCR发作潜伏期值和EBCR平均振幅值参考区间的上下限。EBCR发病潜伏期在13.85 ~ 27.44毫秒之间,而EBCR平均基线到峰值振幅未进行Box-Cox变换。所有EBCR复合肌动作电位均以负尖波开始,负尖波从基线向上逐渐变细,呈上倒的钟形曲线。总之,本研究可能是首次对该方法进行检验,并提供了绝育母犬排尿时EAS肌电图的电图模式和EBCR发病潜伏期的参考间隔,这可能作为基线信息,帮助兽医区分健康犬和患病犬。进一步的研究应该比较正常犬和不同病变部位的下尿路异常犬。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Veterinary Medicine International
Veterinary Medicine International Veterinary-Veterinary (all)
CiteScore
3.50
自引率
3.20%
发文量
55
审稿时长
17 weeks
期刊介绍: Veterinary Medicine International is a peer-reviewed, Open Access journal that publishes original research articles and review articles in all areas of veterinary research. The journal will consider articles on the biological basis of disease, as well as diagnosis, prevention, treatment, and epidemiology.
期刊最新文献
Molecular Epidemiology and Antimicrobial Resistance of Extended-Spectrum β-Lactamase (ESBL)-Producing Klebsiella pneumoniae in Retail Cattle Meat. Ultrasound of the Lacrimal Gland in Healthy Shih Tzu Dogs and with Dry Eye Disease. Prevalence and Associated Risk Factors of Gastrointestinal Parasite Infections among Meat Goats in Khon Kaen Thailand. Seroprevalence and Co-Circulation of Rift Valley Fever Virus and West Nile Fever Virus in Livestock Population of Afar Region, Northeast Ethiopia. The Impact of Dermal Characteristics on Low-Level Laser Power Measurement in Postmortem Zoological Species.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1