Magnetically Detachable Pipe Joints: A Possible Ideal Way to Prevent Unplanned Extubation.

IF 1.2 4区 医学 Q3 SURGERY Surgical Innovation Pub Date : 2023-10-01 Epub Date: 2023-01-27 DOI:10.1177/15533506231154050
Xiaoping Luo, Kexi Pei, Qian Huang, Binfei Li
{"title":"Magnetically Detachable Pipe Joints: A Possible Ideal Way to Prevent Unplanned Extubation.","authors":"Xiaoping Luo,&nbsp;Kexi Pei,&nbsp;Qian Huang,&nbsp;Binfei Li","doi":"10.1177/15533506231154050","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Many indwelling drainage tubes after surgery. Due to the characteristics of the implanted end in the body and the tube fixed in the body, once the force is pulled, it is easy to cause extubation events, and the incidence of unplanned extubation is at a high level. And considerable distress to patients.</p><p><strong>Methods: </strong>We designed a magnetically controlled separable pipe joint device, which can realize the pipe's automatic separation and protection function in a critical state, and protect the patient's pipe from being pulled out when the pipe is affected by an external force. And realize the automatic closing function and automatic alarm function of the broken end after the pipeline is separated, to minimize the occurrence of unplanned extubation.</p><p><strong>Results: </strong>The magnetically-controlled separable pipe joint was initially applied to the clinic. Compared with the traditional drainage tube, the incidence of unplanned extubation time can be effectively reduced, and the safety, portability, and maneuverability have been greatly guaranteed.</p><p><strong>Conclusion: </strong>The magnetron detachable pipe joint device provides a new idea for selecting clinical drainage tubes by improving the defects of traditional drainage tubes. It can effectively prevent the occurrence of unplanned extubation.</p>","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506231154050","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Many indwelling drainage tubes after surgery. Due to the characteristics of the implanted end in the body and the tube fixed in the body, once the force is pulled, it is easy to cause extubation events, and the incidence of unplanned extubation is at a high level. And considerable distress to patients.

Methods: We designed a magnetically controlled separable pipe joint device, which can realize the pipe's automatic separation and protection function in a critical state, and protect the patient's pipe from being pulled out when the pipe is affected by an external force. And realize the automatic closing function and automatic alarm function of the broken end after the pipeline is separated, to minimize the occurrence of unplanned extubation.

Results: The magnetically-controlled separable pipe joint was initially applied to the clinic. Compared with the traditional drainage tube, the incidence of unplanned extubation time can be effectively reduced, and the safety, portability, and maneuverability have been greatly guaranteed.

Conclusion: The magnetron detachable pipe joint device provides a new idea for selecting clinical drainage tubes by improving the defects of traditional drainage tubes. It can effectively prevent the occurrence of unplanned extubation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
磁性可拆卸管接头:防止意外拔管的理想方法。
导语:术后许多留置引流管。由于植入端在体内,导管固定在体内的特点,一旦用力,就容易引发拔管事件,非计划拔管的发生率较高。给病人带来相当大的痛苦。方法:我们设计了一种磁控可分离管接头装置,该装置可以在危急状态下实现管道的自动分离和保护功能,并在管道受到外力影响时保护患者的管道不被拔出。并实现管道分离后断端的自动关闭功能和自动报警功能,最大限度地减少非计划拔管的发生。结果:磁控可分离管接头在临床上初步应用。与传统的引流管相比,可以有效降低非计划拔管时间的发生率,极大地保证了引流管的安全性、便携性和可操作性。结论:磁控管可拆卸管接头装置通过改进传统引流管的缺陷,为临床引流管的选择提供了一种新的思路。可有效预防非计划拔管的发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Surgical Innovation
Surgical Innovation 医学-外科
CiteScore
2.90
自引率
0.00%
发文量
72
审稿时长
6-12 weeks
期刊介绍: Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).
期刊最新文献
The Use of the Symani Surgical System® in Emergency Hand Trauma Care. A Prospective Study on a Suture Force Feedback Device for Training and Evaluating Junior Surgeons in Anastomotic Surgical Closure. The Reconstructive Metaverse - Collaboration in Real-Time Shared Mixed Reality Environments for Microsurgical Reconstruction. Patients Engaged in Losing Weight Preoperatively Experience Improved Outcomes After Hiatal Hernia Repair. Metrics for Success in a Surgical Innovation Fellowship.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1