Fluid structure interaction analysis to stratify the behavior of different atheromatous carotid plaques.

IF 1.4 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Cardiovascular Surgery Pub Date : 2023-02-01 DOI:10.23736/S0021-9509.22.12170-1
Maurizio Domanin, Lorenzo Bennati, Christian Vergara, Daniele Bissacco, Chiara Malloggi, Vincenzo Silani, Gianfranco Parati, Santi Trimarchi, Renato Casana
{"title":"Fluid structure interaction analysis to stratify the behavior of different atheromatous carotid plaques.","authors":"Maurizio Domanin,&nbsp;Lorenzo Bennati,&nbsp;Christian Vergara,&nbsp;Daniele Bissacco,&nbsp;Chiara Malloggi,&nbsp;Vincenzo Silani,&nbsp;Gianfranco Parati,&nbsp;Santi Trimarchi,&nbsp;Renato Casana","doi":"10.23736/S0021-9509.22.12170-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In asymptomatic carotid stenosis (ACS), different plaque types, i.e. lipidic (LP), fibrous (FP), and calcific (CP), could have different hemodynamic and structural behaviors.</p><p><strong>Methods: </strong>Different carotid plaques, reconstructed from medical imaging of ACS >70%, were analyzed by computing fluid structure interaction (FSI), modeling the spatial distribution of wall shear stresses (WSS), plaque displacements (D), von Mises stresses (VMS), and absorbed elastic energy (AEE) together with their maximum-in-space values at the systole (WSS<inf>syst</inf>, D<inf>syst</inf>, VMS<inf>syst</inf> and AEE<inf>syst</inf>).</p><p><strong>Results: </strong>WSS resulted significantly higher in CP, whereas D and VMS showed the highest values for LP. Regarding AEE<inf>syst</inf> stored by the plaques, LP absorbed in average 2320 J/m<sup>3</sup>, FP 408 J/m<sup>3</sup> (470%) and CP 99 J/m<sup>3</sup> (2240%), (P<0.01, P<0.01, and P<0.01, respectively).</p><p><strong>Conclusions: </strong>Depending upon their nature, plaques store different deformations and inner distributions of forces, thus potentially influencing their vulnerability.</p>","PeriodicalId":50245,"journal":{"name":"Journal of Cardiovascular Surgery","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0021-9509.22.12170-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: In asymptomatic carotid stenosis (ACS), different plaque types, i.e. lipidic (LP), fibrous (FP), and calcific (CP), could have different hemodynamic and structural behaviors.

Methods: Different carotid plaques, reconstructed from medical imaging of ACS >70%, were analyzed by computing fluid structure interaction (FSI), modeling the spatial distribution of wall shear stresses (WSS), plaque displacements (D), von Mises stresses (VMS), and absorbed elastic energy (AEE) together with their maximum-in-space values at the systole (WSSsyst, Dsyst, VMSsyst and AEEsyst).

Results: WSS resulted significantly higher in CP, whereas D and VMS showed the highest values for LP. Regarding AEEsyst stored by the plaques, LP absorbed in average 2320 J/m3, FP 408 J/m3 (470%) and CP 99 J/m3 (2240%), (P<0.01, P<0.01, and P<0.01, respectively).

Conclusions: Depending upon their nature, plaques store different deformations and inner distributions of forces, thus potentially influencing their vulnerability.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
流体结构相互作用分析对不同动脉粥样斑块的行为进行分层。
背景:在无症状颈动脉狭窄(ACS)中,不同类型的斑块,即脂质斑块(LP)、纤维状斑块(FP)和钙化斑块(CP),可能具有不同的血流动力学和结构行为。方法:根据ACS >70%的医学影像重建不同的颈动脉斑块,通过计算流体结构相互作用(FSI),模拟壁面剪切应力(WSS)、斑块位移(D)、von Mises应力(VMS)和吸收弹性能(AEE)的空间分布及其在收缩期的最大空间值(WSSsyst、Dsyst、VMSsyst和AEEsyst),对斑块进行分析。结果:WSS导致CP显著增高,而D和VMS显示LP最高。对于斑块储存的AEEsyst, LP平均吸收2320 J/m3, FP平均吸收408 J/m3 (470%), CP平均吸收99 J/m3(2240%)。(结论:根据斑块的性质,斑块储存不同的变形和内部力分布,从而可能影响其易损性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.50
自引率
7.10%
发文量
204
审稿时长
4-8 weeks
期刊介绍: The Journal of Cardiovascular Surgery publishes scientific papers on cardiac, thoracic and vascular surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor. Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.
期刊最新文献
Subclavian artery revascularization with subclavian-carotid transposition for TEVAR and non-TEVAR patients. Current perspectives in acute type B aortic dissections: a literature review. Long-term outcomes of thoracic endovascular aortic repair for the treatment of descending thoracic aortic aneurysms: a systematic review and meta-analysis. Outcomes of Omniflow® II prosthesis used for revascularization in the femoral tract both in infected and non-infected setting. Frozen elephant trunk technique for aortic arch surgery: the Bordeaux University Hospital experience with Thoraflex hybrid prosthesis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1