Use of the universal scan template to achieve a predictable optical impression: Preliminary data of a case series study in complete edentulous patients

IF 3.7 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Implant Dentistry and Related Research Pub Date : 2023-11-15 DOI:10.1111/cid.13292
Veronica Campana DDS, Andrea Papa MID, Manuel Amilcare Silvetti DDS, Massimo Del Fabbro MSc, PhD, Tiziano Testori MD, DDS, MSc, FICD
{"title":"Use of the universal scan template to achieve a predictable optical impression: Preliminary data of a case series study in complete edentulous patients","authors":"Veronica Campana DDS,&nbsp;Andrea Papa MID,&nbsp;Manuel Amilcare Silvetti DDS,&nbsp;Massimo Del Fabbro MSc, PhD,&nbsp;Tiziano Testori MD, DDS, MSc, FICD","doi":"10.1111/cid.13292","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Full-arch IOS scan of edentulous areas rehabilitated with dental implants is nowadays still described as an unpredictable procedure. To improve the accuracy, a universal scan template (UST®) is proposed in this article. The clinician can easily assemble the template with a mechanical coupling, by matching the scan bodies with objects of known dimension characterized by specific markers. The UST® facilitates the scanning of an entire arch on scan bodies, reducing the learning curve, simplifying acquisition movements, shortening the scanning time, and drastically reducing the risk of distortions and aberrations of the scans.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>In a case series study on 12 patients, the improvement in the accuracy of the scans with UST® was validated by comparing the STL files derived from scans with and without the guide in place. A titanium bar was produced from each optical impression.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The bars obtained from the optical impressions taken without UST® were found to be nonpassive in the mouth in the majority of the cases. On the contrary with the use of UST® we obtained 12 passive prosthetic rehabilitations.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The proposed solution may represent a valid method to improve the predictability of full arch optical impressions on implants.</p>\n </section>\n </div>","PeriodicalId":50679,"journal":{"name":"Clinical Implant Dentistry and Related Research","volume":"26 1","pages":"237-244"},"PeriodicalIF":3.7000,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cid.13292","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Implant Dentistry and Related Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cid.13292","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Full-arch IOS scan of edentulous areas rehabilitated with dental implants is nowadays still described as an unpredictable procedure. To improve the accuracy, a universal scan template (UST®) is proposed in this article. The clinician can easily assemble the template with a mechanical coupling, by matching the scan bodies with objects of known dimension characterized by specific markers. The UST® facilitates the scanning of an entire arch on scan bodies, reducing the learning curve, simplifying acquisition movements, shortening the scanning time, and drastically reducing the risk of distortions and aberrations of the scans.

Materials and Methods

In a case series study on 12 patients, the improvement in the accuracy of the scans with UST® was validated by comparing the STL files derived from scans with and without the guide in place. A titanium bar was produced from each optical impression.

Results

The bars obtained from the optical impressions taken without UST® were found to be nonpassive in the mouth in the majority of the cases. On the contrary with the use of UST® we obtained 12 passive prosthetic rehabilitations.

Conclusions

The proposed solution may represent a valid method to improve the predictability of full arch optical impressions on implants.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用通用扫描模板实现可预测的光学印象:一个完整无牙患者病例系列研究的初步数据。
背景:全弓IOS扫描无牙区修复种植牙目前仍被描述为一个不可预测的程序。为了提高扫描精度,本文提出了一种通用扫描模板(UST®)。通过将扫描体与具有特定标记的已知尺寸的物体相匹配,临床医生可以轻松地用机械耦合组装模板。UST®有利于扫描体上的整个拱门的扫描,减少了学习曲线,简化了采集运动,缩短了扫描时间,并大大降低了扫描失真和畸变的风险。材料和方法:在12例患者的病例系列研究中,通过比较有和没有指南的扫描产生的STL文件,验证了UST®扫描准确性的提高。每个光学印模产生一根钛棒。结果:在大多数情况下,未使用UST®的光学印模获得的棒在口腔中是非被动的。与使用UST®相反,我们获得了12个被动假肢康复。结论:所提出的解决方案可能是一种有效的方法,可以提高种植体全弓光学印模的可预测性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.00
自引率
13.90%
发文量
103
审稿时长
4-8 weeks
期刊介绍: The goal of Clinical Implant Dentistry and Related Research is to advance the scientific and technical aspects relating to dental implants and related scientific subjects. Dissemination of new and evolving information related to dental implants and the related science is the primary goal of our journal. The range of topics covered by the journals will include but be not limited to: New scientific developments relating to bone Implant surfaces and their relationship to the surrounding tissues Computer aided implant designs Computer aided prosthetic designs Immediate implant loading Immediate implant placement Materials relating to bone induction and conduction New surgical methods relating to implant placement New materials and methods relating to implant restorations Methods for determining implant stability A primary focus of the journal is publication of evidenced based articles evaluating to new dental implants, techniques and multicenter studies evaluating these treatments. In addition basic science research relating to wound healing and osseointegration will be an important focus for the journal.
期刊最新文献
Issue Information Featured Cover A transcrestal sinus floor elevation strategy based on a haptic robot system: An in vitro study Influence of repeated implant‐abutment manipulation on the prevalence of peri‐implant diseases in complete arch restorations. A retrospective analysis Biocompatibility and dimensional stability through the use of 3D‐printed scaffolds made by polycaprolactone and bioglass‐7: An in vitro and in vivo study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1