B Teisseire, L Teisseire, A Lautier, R Hérigault, D Laurent
{"title":"A method of continuous recording on microsamples of the Hb-O2 association curve. I. Technique and direct registration of standard results.","authors":"B Teisseire, L Teisseire, A Lautier, R Hérigault, D Laurent","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A modified technique for continuous recording of the Hb-O2 association curve for blood samples is proposed. The following alterations to the classical method of Duvelleroy et al. (5) were studied and validated: 1) dilution of blood micro-samples (200-400 mul) to 10 ml of a buffered phosphate solution; 2) use of a (CO2, O2) mixture allowing the maintenance of standard conditions (pH=7.40, PCO2=40 Torr) during the entire oxygenation process. The advantages of such modifications were: 1) reducing the time necessary for both deoxygenation and drawing Hb-O2 association curve (to about 20 min), hence permitting to work out large series of samples; 2) avoiding the necessity of imprecise a posteriori corrections, thus permitting analysis of the different components of the BOHR effect.</p>","PeriodicalId":75638,"journal":{"name":"Bulletin de physio-pathologie respiratoire","volume":"11 6","pages":"837-51"},"PeriodicalIF":0.0000,"publicationDate":"1975-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin de physio-pathologie respiratoire","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A modified technique for continuous recording of the Hb-O2 association curve for blood samples is proposed. The following alterations to the classical method of Duvelleroy et al. (5) were studied and validated: 1) dilution of blood micro-samples (200-400 mul) to 10 ml of a buffered phosphate solution; 2) use of a (CO2, O2) mixture allowing the maintenance of standard conditions (pH=7.40, PCO2=40 Torr) during the entire oxygenation process. The advantages of such modifications were: 1) reducing the time necessary for both deoxygenation and drawing Hb-O2 association curve (to about 20 min), hence permitting to work out large series of samples; 2) avoiding the necessity of imprecise a posteriori corrections, thus permitting analysis of the different components of the BOHR effect.