Tracking body core temperature in military thermal environments: An extended Kalman filter approach

K. Seng, Ying Chen, K. M. A. Chai, Ting Wang, David Chiok Yuen Fun, Y. S. Teo, P. Tan, W. Ang, J. Lee
{"title":"Tracking body core temperature in military thermal environments: An extended Kalman filter approach","authors":"K. Seng, Ying Chen, K. M. A. Chai, Ting Wang, David Chiok Yuen Fun, Y. S. Teo, P. Tan, W. Ang, J. Lee","doi":"10.1109/BSN.2016.7516277","DOIUrl":null,"url":null,"abstract":"Military personnel operating in hot and humid environments are susceptible to heat-related illnesses. As heat-related illnesses are associated with a rise in body core temperature (Tc), a reliable system for real-time assessment of Tc is useful to minimize heat casualties. However, invasive measurement of Tc (such as rectal, intestinal and esophageal temperature) is impractical in the field settings. This paper describes the model construction and qualification results of tracking Tc using an extended Kalman filter (EKF) based on physiological data recorded from wearable sensors. Tc, surface skin temperature (Tsk) and heart rate (HR) data were collected from three studies with different experimental protocols, climatic conditions and soldier volunteers. The predictive performance of the model was evaluated by cross-validation and external validation. The final EKF model was implemented using a nonlinear (cubic) state-space model (Tsk versus Tc) with a stage-wise, autoregressive exogenous model (incorporating HR) as the time update model. Overall, when tested against an independent dataset, the model showed a prediction bias of 0.11°C, a root mean square deviation of 0.29°C, and 87% of all Tc predictions fell within ±0.3°C of the measured Tc values. The results from our study indicate that the derived EKF model is accurate enough to calculate subject-specific Tc for the minimization of heat injuries.","PeriodicalId":205735,"journal":{"name":"2016 IEEE 13th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","volume":"75 11","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 13th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BSN.2016.7516277","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Military personnel operating in hot and humid environments are susceptible to heat-related illnesses. As heat-related illnesses are associated with a rise in body core temperature (Tc), a reliable system for real-time assessment of Tc is useful to minimize heat casualties. However, invasive measurement of Tc (such as rectal, intestinal and esophageal temperature) is impractical in the field settings. This paper describes the model construction and qualification results of tracking Tc using an extended Kalman filter (EKF) based on physiological data recorded from wearable sensors. Tc, surface skin temperature (Tsk) and heart rate (HR) data were collected from three studies with different experimental protocols, climatic conditions and soldier volunteers. The predictive performance of the model was evaluated by cross-validation and external validation. The final EKF model was implemented using a nonlinear (cubic) state-space model (Tsk versus Tc) with a stage-wise, autoregressive exogenous model (incorporating HR) as the time update model. Overall, when tested against an independent dataset, the model showed a prediction bias of 0.11°C, a root mean square deviation of 0.29°C, and 87% of all Tc predictions fell within ±0.3°C of the measured Tc values. The results from our study indicate that the derived EKF model is accurate enough to calculate subject-specific Tc for the minimization of heat injuries.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
军用热环境下人体核心温度的跟踪:一种扩展的卡尔曼滤波方法
在炎热潮湿的环境中工作的军事人员容易患与热有关的疾病。由于热相关疾病与身体核心温度(Tc)的升高有关,一个可靠的实时评估Tc的系统有助于减少热伤亡。然而,有创测量Tc(如直肠、肠道和食管温度)在现场是不切实际的。本文介绍了基于可穿戴传感器记录的生理数据,利用扩展卡尔曼滤波(EKF)对Tc进行跟踪的模型构建和验证结果。Tc、体表皮肤温度(Tsk)和心率(HR)数据收集自三个不同实验方案、气候条件和士兵志愿者的研究。通过交叉验证和外部验证对模型的预测性能进行评价。最终的EKF模型是使用非线性(三次)状态空间模型(Tsk vs . Tc)和一个分阶段、自回归的外生模型(包含HR)作为时间更新模型来实现的。总体而言,当针对独立数据集进行测试时,该模型的预测偏差为0.11°C,均方根偏差为0.29°C, 87%的Tc预测落在测量Tc值的±0.3°C范围内。我们的研究结果表明,导出的EKF模型足够精确,可以计算受试者特定的Tc,以最大限度地减少热损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Edemeter: Wearable and continuous fluid retention monitoring Probabilistic sensor network design Tracking body core temperature in military thermal environments: An extended Kalman filter approach A multimodal sensor system for automated marmoset behavioral analysis Accurate personal ultraviolet dose estimation with multiple wearable sensors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1