{"title":"Iterative reconstruction with attenuation compensation from cone-beam projections acquired via non-planar orbit","authors":"Y. Weng, G. L. Zeng, G. Gullberg","doi":"10.1109/NSSMIC.1995.510489","DOIUrl":null,"url":null,"abstract":"Single photon emission computed tomography (SPECT) imaging with cone-beam collimators provides improved sensitivity and spatial resolution for imaging small objects with large field-of-view detectors. It is known that Tuy's (1983) cone-beam data sufficiency condition must be met in order to obtain artifact-free reconstructions. Even though Tuy's condition was derived for attenuation-free situation, the authors hypothesize that an artifact-free reconstruction can be obtained even if the cone-beam data are attenuated, provided the imaging orbit satisfies Tuy's condition and the exact attenuation map. In the authors' studies, emission data are acquired using nonplanar orbit such as circle-and-line orbit to acquire sufficient data for cone-beam tomographic reconstruction. An iterative conjugate gradient reconstruction algorithm is used to reconstruct projection data with a pre-acquired attenuation map. Quantitative accuracy of the attenuation corrected emission reconstruction is significantly improved. The authors observe that the cone-beam iterative algorithms are very sensitive to the projection and backprojection models, because each voxel is sampled anisotropically. Sampling artifacts (i.e., aliasing artifacts) sometimes are very severe for non-planar orbit data acquisition geometries. Better voxel models and sampling geometries are required in further investigations.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"6 1-2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.510489","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22
Abstract
Single photon emission computed tomography (SPECT) imaging with cone-beam collimators provides improved sensitivity and spatial resolution for imaging small objects with large field-of-view detectors. It is known that Tuy's (1983) cone-beam data sufficiency condition must be met in order to obtain artifact-free reconstructions. Even though Tuy's condition was derived for attenuation-free situation, the authors hypothesize that an artifact-free reconstruction can be obtained even if the cone-beam data are attenuated, provided the imaging orbit satisfies Tuy's condition and the exact attenuation map. In the authors' studies, emission data are acquired using nonplanar orbit such as circle-and-line orbit to acquire sufficient data for cone-beam tomographic reconstruction. An iterative conjugate gradient reconstruction algorithm is used to reconstruct projection data with a pre-acquired attenuation map. Quantitative accuracy of the attenuation corrected emission reconstruction is significantly improved. The authors observe that the cone-beam iterative algorithms are very sensitive to the projection and backprojection models, because each voxel is sampled anisotropically. Sampling artifacts (i.e., aliasing artifacts) sometimes are very severe for non-planar orbit data acquisition geometries. Better voxel models and sampling geometries are required in further investigations.