Iterative reconstruction with attenuation compensation from cone-beam projections acquired via non-planar orbit

Y. Weng, G. L. Zeng, G. Gullberg
{"title":"Iterative reconstruction with attenuation compensation from cone-beam projections acquired via non-planar orbit","authors":"Y. Weng, G. L. Zeng, G. Gullberg","doi":"10.1109/NSSMIC.1995.510489","DOIUrl":null,"url":null,"abstract":"Single photon emission computed tomography (SPECT) imaging with cone-beam collimators provides improved sensitivity and spatial resolution for imaging small objects with large field-of-view detectors. It is known that Tuy's (1983) cone-beam data sufficiency condition must be met in order to obtain artifact-free reconstructions. Even though Tuy's condition was derived for attenuation-free situation, the authors hypothesize that an artifact-free reconstruction can be obtained even if the cone-beam data are attenuated, provided the imaging orbit satisfies Tuy's condition and the exact attenuation map. In the authors' studies, emission data are acquired using nonplanar orbit such as circle-and-line orbit to acquire sufficient data for cone-beam tomographic reconstruction. An iterative conjugate gradient reconstruction algorithm is used to reconstruct projection data with a pre-acquired attenuation map. Quantitative accuracy of the attenuation corrected emission reconstruction is significantly improved. The authors observe that the cone-beam iterative algorithms are very sensitive to the projection and backprojection models, because each voxel is sampled anisotropically. Sampling artifacts (i.e., aliasing artifacts) sometimes are very severe for non-planar orbit data acquisition geometries. Better voxel models and sampling geometries are required in further investigations.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"6 1-2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.510489","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

Abstract

Single photon emission computed tomography (SPECT) imaging with cone-beam collimators provides improved sensitivity and spatial resolution for imaging small objects with large field-of-view detectors. It is known that Tuy's (1983) cone-beam data sufficiency condition must be met in order to obtain artifact-free reconstructions. Even though Tuy's condition was derived for attenuation-free situation, the authors hypothesize that an artifact-free reconstruction can be obtained even if the cone-beam data are attenuated, provided the imaging orbit satisfies Tuy's condition and the exact attenuation map. In the authors' studies, emission data are acquired using nonplanar orbit such as circle-and-line orbit to acquire sufficient data for cone-beam tomographic reconstruction. An iterative conjugate gradient reconstruction algorithm is used to reconstruct projection data with a pre-acquired attenuation map. Quantitative accuracy of the attenuation corrected emission reconstruction is significantly improved. The authors observe that the cone-beam iterative algorithms are very sensitive to the projection and backprojection models, because each voxel is sampled anisotropically. Sampling artifacts (i.e., aliasing artifacts) sometimes are very severe for non-planar orbit data acquisition geometries. Better voxel models and sampling geometries are required in further investigations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于非平面轨道锥束投影的衰减补偿迭代重建
单光子发射计算机断层扫描(SPECT)成像与锥束准直器提供了改进的灵敏度和空间分辨率成像的小目标与大视场探测器。众所周知,要获得无伪影重建,必须满足Tuy(1983)的锥束数据充要条件。尽管在无衰减情况下导出了Tuy条件,但作者假设,只要成像轨道满足Tuy条件和精确的衰减图,即使锥束数据被衰减,也可以获得无伪影重构。在作者的研究中,发射数据的获取采用非平面轨道,如圆-线轨道,以获得足够的数据进行锥束层析重建。采用迭代共轭梯度重构算法,利用预获取的衰减图重构投影数据。衰减校正发射重建的定量精度显著提高。作者观察到锥束迭代算法对投影和反投影模型非常敏感,因为每个体素都是各向异性采样的。采样伪影(即混叠伪影)有时对非平面轨道数据采集几何非常严重。在进一步的研究中需要更好的体素模型和采样几何。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The performance of the DELPHI Hadron Calorimeter at LEP AlGaAs/GaAs avalanche detector array -1 GBit/s X-ray receiver for timing measurements Parallelization of 3-D PET BpjF reconstruction on a DSP cluster Noise analysis of low noise, high count rate, PIN diode X-ray detectors Iterative reconstruction with attenuation compensation from cone-beam projections acquired via non-planar orbit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1