BaTiO3 sensitive film enhancement for CO2 detection

F. Pennec, E. Amine, S. Bernardini, C. Perrin-Pellegrino, K. Aguir, M. Bendahan
{"title":"BaTiO3 sensitive film enhancement for CO2 detection","authors":"F. Pennec, E. Amine, S. Bernardini, C. Perrin-Pellegrino, K. Aguir, M. Bendahan","doi":"10.1109/SENSORS47125.2020.9278726","DOIUrl":null,"url":null,"abstract":"A barium titanate thin film was deposited by drop coating for carbon dioxide detection. The measurements are based on a resistance change and provided a sensitive response to different CO2 concentrations under a humidity environment. The concentration measurement range was between 100 and 5000 ppm of CO2 in synthetic air, and likewise, the relative humidity was between 20 and 70%. The response and recovery times of the BaTiO3 based resistive sensors were determined to 2 min and 4 min, respectively, for 400 ppm of carbon dioxide and 50% relative humidity.","PeriodicalId":338240,"journal":{"name":"2020 IEEE Sensors","volume":"38 12","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSORS47125.2020.9278726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A barium titanate thin film was deposited by drop coating for carbon dioxide detection. The measurements are based on a resistance change and provided a sensitive response to different CO2 concentrations under a humidity environment. The concentration measurement range was between 100 and 5000 ppm of CO2 in synthetic air, and likewise, the relative humidity was between 20 and 70%. The response and recovery times of the BaTiO3 based resistive sensors were determined to 2 min and 4 min, respectively, for 400 ppm of carbon dioxide and 50% relative humidity.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
BaTiO3敏感膜增强CO2检测
采用滴涂法制备了一种用于二氧化碳检测的钛酸钡薄膜。测量基于电阻变化,并在湿度环境下对不同的CO2浓度提供敏感响应。测量范围为合成空气中CO2浓度为100 ~ 5000ppm,相对湿度为20% ~ 70%。在二氧化碳浓度为400ppm、相对湿度为50%的条件下,BaTiO3电阻式传感器的响应时间和恢复时间分别为2min和4min。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Quartz Crystal Microbalance Sensor Based on Peptide Anchored Single-Walled Carbon Nanotubes for Highly Selective TNT Explosive Detection BaTiO3 sensitive film enhancement for CO2 detection Comparable Data Evaluation Method for a Radio-Nuclear Sensor When Used on an UAV Reusable acoustic tweezers enable 2D patterning of microparticles in microchamber on a disposable silicon chip superstrate Optimizing Novel Inorganic Scintillation Detectors for Applications in Medical Physics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1