True RMS power detection with high dynamic range

G. Klahn
{"title":"True RMS power detection with high dynamic range","authors":"G. Klahn","doi":"10.1109/MWSYM.1999.780315","DOIUrl":null,"url":null,"abstract":"All communication systems require some form of output power reporting as a means to manage the power efficiency of the output spectrum. Traditionally, this task has been performed with diode detectors. Diode detectors are non-linear devices and require elaborate compensation techniques to linearize and operate as a true RMS (Root Mean Square) detector over a wide dynamic and temperature range. A true RMS power detection scheme has been developed, which has a 22 dB dynamic range with /spl plusmn/1 dB accuracy and operates over a temperature range of -40/spl deg/C to +80/spl deg/C.","PeriodicalId":339267,"journal":{"name":"1999 IEEE MTT-S International Microwave Symposium Digest (Cat. No.99CH36282)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 IEEE MTT-S International Microwave Symposium Digest (Cat. No.99CH36282)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.1999.780315","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

All communication systems require some form of output power reporting as a means to manage the power efficiency of the output spectrum. Traditionally, this task has been performed with diode detectors. Diode detectors are non-linear devices and require elaborate compensation techniques to linearize and operate as a true RMS (Root Mean Square) detector over a wide dynamic and temperature range. A true RMS power detection scheme has been developed, which has a 22 dB dynamic range with /spl plusmn/1 dB accuracy and operates over a temperature range of -40/spl deg/C to +80/spl deg/C.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
真正的均方根功率检测与高动态范围
所有通信系统都需要某种形式的输出功率报告,作为管理输出频谱功率效率的一种手段。传统上,这项任务是用二极管探测器完成的。二极管检测器是非线性器件,需要复杂的补偿技术来线性化并在宽动态和温度范围内作为真正的均方根检测器运行。开发了一种真正的均方根功率检测方案,其动态范围为22 dB,精度为/spl plusmn/1 dB,工作温度范围为-40/spl°C至+80/spl°C。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of a 15 GHz FMCW radar for industrial control and process level measurement True RMS power detection with high dynamic range Low-loss, planar monolithic baluns for K/Ka-band applications Fundamental artificial periodic substrate effects on printed circuit antennas High breakdown voltage InAlGaAs/In/sub 0.32/Ga/sub 0.68/As metamorphic HEMT for microwave and MM-wave power applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1