Diagnostic Testing of Power Cable Insulation For Reliable Smart Grid Operation

S. Morsalin, A. Sahoo, B. Phung
{"title":"Diagnostic Testing of Power Cable Insulation For Reliable Smart Grid Operation","authors":"S. Morsalin, A. Sahoo, B. Phung","doi":"10.1109/EIC43217.2019.9046619","DOIUrl":null,"url":null,"abstract":"Polymeric insulation, especially cross-linked polyethylene (XLPE) insulated power cables are widely used in practice to transport electrical energy. XLPE has excellent dielectric properties, but its degradation due to various factors while in service is unlikely to avoid. Moreover, electrical, mechanical or thermal stresses accelerate the ageing process and shorten the lifespan. In the era of smart grid, its safe and reliable operation is vital. Hence, condition monitoring of insulation through diagnostic testing has become critically important to the smart maintenance of electrical infrastructure. In this paper, the diagnostic behaviors of XLPE insulation are explained by using two popular diagnostic methods, partial discharge (PD) and dielectric response (DR) measurements. For PD diagnosis, a comparative study of surface discharge and their characteristics under conventional power frequency (50 Hz) and very low frequency (0.1 Hz) excitation are presented. Dielectric responses are investigated in the frequency domain by $\\mathrm{tan}\\delta$ measurement and in the time domain by pol/depolarization current measurement. It is shown that useful information for insulation diagnosis can be extracted from the measurement results.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046619","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Polymeric insulation, especially cross-linked polyethylene (XLPE) insulated power cables are widely used in practice to transport electrical energy. XLPE has excellent dielectric properties, but its degradation due to various factors while in service is unlikely to avoid. Moreover, electrical, mechanical or thermal stresses accelerate the ageing process and shorten the lifespan. In the era of smart grid, its safe and reliable operation is vital. Hence, condition monitoring of insulation through diagnostic testing has become critically important to the smart maintenance of electrical infrastructure. In this paper, the diagnostic behaviors of XLPE insulation are explained by using two popular diagnostic methods, partial discharge (PD) and dielectric response (DR) measurements. For PD diagnosis, a comparative study of surface discharge and their characteristics under conventional power frequency (50 Hz) and very low frequency (0.1 Hz) excitation are presented. Dielectric responses are investigated in the frequency domain by $\mathrm{tan}\delta$ measurement and in the time domain by pol/depolarization current measurement. It is shown that useful information for insulation diagnosis can be extracted from the measurement results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
面向智能电网可靠运行的电力电缆绝缘诊断试验
聚合物绝缘,特别是交联聚乙烯(XLPE)绝缘电力电缆在实际中广泛用于传输电能。XLPE具有优良的介电性能,但在使用过程中由于各种因素的影响,其性能的下降是不可避免的。此外,电、机械或热应力加速了老化过程,缩短了寿命。在智能电网时代,其安全可靠运行至关重要。因此,通过诊断测试对绝缘进行状态监测对于电力基础设施的智能维护至关重要。本文用两种常用的诊断方法——局部放电(PD)和介电响应(DR)测量来解释XLPE绝缘的诊断行为。在常规工频(50 Hz)和极低频(0.1 Hz)激励下,对表面放电及其特性进行了比较研究。在频域采用$\ mathm {tan}\delta$测量,在时域采用pol/去极化电流测量。结果表明,从测量结果中可以提取出有用的绝缘诊断信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diagnostic Testing of Power Cable Insulation For Reliable Smart Grid Operation Investigation of the Thickness Effect on DC Breakdown Strength for HVDC Flexible Cable Insulation Associated with Space Charge Classification of Insulating Liquids Thermal Treatment Using Infrared Spectroscopy and Multivariate Statistical Method Study on the Ageing Characteristics of Persea Americana Oil as an Alternative Transformer Insulation oil Evaluation of Nano-Composite XLPE Compound on Accelerated Aging Cable Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1