Singles transmission scanning for rotating positron cameras with large-area detectors

K. Erlandsson, N. Evans, L. White, M. Flower, A. Reader, D. Duxbury, R. Ott
{"title":"Singles transmission scanning for rotating positron cameras with large-area detectors","authors":"K. Erlandsson, N. Evans, L. White, M. Flower, A. Reader, D. Duxbury, R. Ott","doi":"10.1109/NSSMIC.1998.773927","DOIUrl":null,"url":null,"abstract":"This paper describes the novel geometry and initial results of a singles transmission system for PETRRA, a whole-body PET camera with 400/spl times/600 mm BaF/sub 2/-TMAE detectors. Special frames mounted on to the front face of each detector support a collimated Cs-137 source in various positions. Cone-beam transmission data are acquired during 360/spl deg/ gantry rotation and images are reconstructed using the Feldkamp algorithm. The radial field of view (FOV) can be increased by using two source positions displaced either side of the central position. The truncated data acquired from each source position are combined to form a complete dataset. The axial FOV depends on the amount of collimation in the axial direction and could be increased by horizontal couch motion. Preliminary singles transmission images of both real and simulated thorax phantoms have been obtained. The effects of varying the linear sampling interval, the number of projections and the axial FOV have been studied. The singles transmission scanning system, described here and developed for PETRRA, could be applied to other PET cameras with large planar detectors.","PeriodicalId":129202,"journal":{"name":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","volume":"315 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1998.773927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper describes the novel geometry and initial results of a singles transmission system for PETRRA, a whole-body PET camera with 400/spl times/600 mm BaF/sub 2/-TMAE detectors. Special frames mounted on to the front face of each detector support a collimated Cs-137 source in various positions. Cone-beam transmission data are acquired during 360/spl deg/ gantry rotation and images are reconstructed using the Feldkamp algorithm. The radial field of view (FOV) can be increased by using two source positions displaced either side of the central position. The truncated data acquired from each source position are combined to form a complete dataset. The axial FOV depends on the amount of collimation in the axial direction and could be increased by horizontal couch motion. Preliminary singles transmission images of both real and simulated thorax phantoms have been obtained. The effects of varying the linear sampling interval, the number of projections and the axial FOV have been studied. The singles transmission scanning system, described here and developed for PETRRA, could be applied to other PET cameras with large planar detectors.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
带大面积探测器的旋转正电子相机的单透射扫描
本文描述了用于PETRRA的单传输系统的新几何结构和初步结果,PETRRA是一种全身PET相机,具有400/spl倍/600 mm BaF/sub 2/-TMAE探测器。安装在每个探测器正面的特殊框架支持在不同位置的准直Cs-137源。在360度/spl度/龙门旋转过程中获取锥束传输数据,并使用Feldkamp算法重建图像。径向视场(FOV)可以通过在中心位置两侧使用两个源位置来增加。从每个源位置获取的截断数据被组合成一个完整的数据集。轴向视场取决于轴向准直的量,可以通过水平运动增加。初步获得了真实和模拟胸腔幻象的单次传输图像。研究了线性采样间隔、投影数和轴向视场的影响。这里描述的为PETRRA开发的单透射扫描系统可以应用于其他具有大型平面探测器的PET相机。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The NA48 liquid krypton calorimeter description and performances An evaluation of radioxenon detection techniques for use with a fluid-based concentration system Development of a high speed X-ray tomography system for multiphase flow imaging Method for evaluation of different MRI segmentation approaches Singles transmission scanning for rotating positron cameras with large-area detectors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1