Assessing and mitigating impact of time delay attack: a case study for power grid frequency control

Xin Lou, Cuong Tran, Rui Tan, David K. Y. Yau, Z. Kalbarczyk
{"title":"Assessing and mitigating impact of time delay attack: a case study for power grid frequency control","authors":"Xin Lou, Cuong Tran, Rui Tan, David K. Y. Yau, Z. Kalbarczyk","doi":"10.1145/3302509.3311042","DOIUrl":null,"url":null,"abstract":"Recent attacks against cyber-physical systems (CPSes) show that traditional reliance on isolation for security is insufficient. This paper develops efficient assessment and mitigation of an attack's impact as a system's built-in mechanisms. We focus on a general class of attacks, which we call time delay attack, that delays the transmissions of control data packets in a linear CPS control system. Our attack impact assessment, which is based on a joint stability-safety criterion, consists of (i) a machine learning (ML) based safety classification, and (ii) a tandem stability-safety classification that exploits a basic relationship between stability and safety, namely that an unstable system must be unsafe whereas a stable system may not be safe. The ML addresses a state explosion problem in the safety classification, whereas the tandem structure reduces false negatives in detecting unsafety arising from imperfect ML. We apply our approach to assess the impact of the attack on power grid automatic generation control, and accordingly develop a two-tiered mitigation that tunes the control gain automatically to restore safety where necessary and shed load only if the tuning is insufficient. Extensive simulations based on a 37-bus system model are conducted to evaluate the effectiveness of our assessment and mitigation approaches.","PeriodicalId":413733,"journal":{"name":"Proceedings of the 10th ACM/IEEE International Conference on Cyber-Physical Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 10th ACM/IEEE International Conference on Cyber-Physical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3302509.3311042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Recent attacks against cyber-physical systems (CPSes) show that traditional reliance on isolation for security is insufficient. This paper develops efficient assessment and mitigation of an attack's impact as a system's built-in mechanisms. We focus on a general class of attacks, which we call time delay attack, that delays the transmissions of control data packets in a linear CPS control system. Our attack impact assessment, which is based on a joint stability-safety criterion, consists of (i) a machine learning (ML) based safety classification, and (ii) a tandem stability-safety classification that exploits a basic relationship between stability and safety, namely that an unstable system must be unsafe whereas a stable system may not be safe. The ML addresses a state explosion problem in the safety classification, whereas the tandem structure reduces false negatives in detecting unsafety arising from imperfect ML. We apply our approach to assess the impact of the attack on power grid automatic generation control, and accordingly develop a two-tiered mitigation that tunes the control gain automatically to restore safety where necessary and shed load only if the tuning is insufficient. Extensive simulations based on a 37-bus system model are conducted to evaluate the effectiveness of our assessment and mitigation approaches.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估和减轻时间延迟攻击的影响:电网频率控制的案例研究
最近针对网络物理系统(cpse)的攻击表明,传统的隔离安全依赖是不够的。本文开发了作为系统内置机制的有效评估和减轻攻击影响的方法。我们关注的是一类一般的攻击,我们称之为延时攻击,它延迟了线性CPS控制系统中控制数据包的传输。我们的攻击影响评估基于联合稳定安全标准,包括(i)基于机器学习(ML)的安全分类,以及(ii)利用稳定与安全之间基本关系的串联稳定安全分类,即不稳定的系统一定是不安全的,而稳定的系统可能不安全。机器学习解决了安全分类中的状态爆炸问题,而串联结构在检测不完美机器学习引起的不安全时减少了假阴性。我们应用我们的方法来评估攻击对电网自动发电控制的影响,并相应地开发了一种双层缓解方法,该方法可以自动调整控制增益以在必要时恢复安全,并仅在调整不足时卸载负载。基于37总线系统模型进行了广泛的模拟,以评估我们的评估和缓解方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessing and mitigating impact of time delay attack: a case study for power grid frequency control Programming event processors with thingflow FPGA-Based amoeba-inspired SAT solver for cyber-physical systems TACAN Robustness evaluation of computer-aided clinical trials for medical devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1