{"title":"Analysis for simplified optics coma effection on spectral image inversion of coded aperture spectral imager","authors":"Yangyang Liu, Qunbo Lv, Weiyan Li, Bin Xiangli","doi":"10.1117/12.2192067","DOIUrl":null,"url":null,"abstract":"As a novel spectrum imaging technology was developed recent years, push-broom coded aperture spectral imaging (PCASI) has the advantages of high throughput, high SNR, high stability etc. This coded aperture spectral imaging utilizes fixed code templates and push-broom mode, which can realize the high-precision reconstruction of spatial and spectral information. But during optical lens designing, manufacturing and debugging, it is inevitably exist some minor coma errors. Even minor coma errors can reduce image quality. In this paper, we simulated the system optical coma error’s influence to the quality of reconstructed image, analyzed the variant of the coded aperture in different optical coma effect, then proposed an accurate curve of image quality and optical coma quality in 255×255 size code template, which provide important references for design and development of push-broom coded aperture spectrometer.","PeriodicalId":212434,"journal":{"name":"SPIE Optical Systems Design","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPIE Optical Systems Design","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2192067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
As a novel spectrum imaging technology was developed recent years, push-broom coded aperture spectral imaging (PCASI) has the advantages of high throughput, high SNR, high stability etc. This coded aperture spectral imaging utilizes fixed code templates and push-broom mode, which can realize the high-precision reconstruction of spatial and spectral information. But during optical lens designing, manufacturing and debugging, it is inevitably exist some minor coma errors. Even minor coma errors can reduce image quality. In this paper, we simulated the system optical coma error’s influence to the quality of reconstructed image, analyzed the variant of the coded aperture in different optical coma effect, then proposed an accurate curve of image quality and optical coma quality in 255×255 size code template, which provide important references for design and development of push-broom coded aperture spectrometer.