A normalization technique for multispectral acquisition in positron emission tomography

P. Msaki, M. Bentourkia, J. Cadorette, M. Héon, R. Lecomte
{"title":"A normalization technique for multispectral acquisition in positron emission tomography","authors":"P. Msaki, M. Bentourkia, J. Cadorette, M. Héon, R. Lecomte","doi":"10.1109/NSSMIC.1992.301087","DOIUrl":null,"url":null,"abstract":"A novel normalization technique for multispectral acquisition (MSA) in positron emission tomography (PET) imaging is described. MSA data are affected by spectral nonuniformity due to variations in detector characteristics. As with conventional methods, the normalization must preserve counts as it reduces nonuniformity but spectral shapes must be restored and symmetry distortions between mirror windows must be compensated. The proposed method achieves these goals by averaging each window pair over all detectors and by balancing mirror windows. The method was tested with a variety of spectral distortions and was found to be successful in restoring data uniformity. It is concluded that MSA PET imaging is possible with relatively nonuniform detector response, but with stable detector characteristics are essential.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1992.301087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A novel normalization technique for multispectral acquisition (MSA) in positron emission tomography (PET) imaging is described. MSA data are affected by spectral nonuniformity due to variations in detector characteristics. As with conventional methods, the normalization must preserve counts as it reduces nonuniformity but spectral shapes must be restored and symmetry distortions between mirror windows must be compensated. The proposed method achieves these goals by averaging each window pair over all detectors and by balancing mirror windows. The method was tested with a variety of spectral distortions and was found to be successful in restoring data uniformity. It is concluded that MSA PET imaging is possible with relatively nonuniform detector response, but with stable detector characteristics are essential.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正电子发射层析成像中多光谱采集的归一化技术
介绍了一种新的正电子发射断层扫描(PET)多光谱采集(MSA)归一化技术。由于探测器特性的变化,MSA数据受到光谱不均匀性的影响。与传统方法一样,归一化必须保留计数,因为它减少了非均匀性,但必须恢复光谱形状,并且必须补偿镜面之间的对称畸变。所提出的方法通过对所有检测器上的每个窗口对进行平均并平衡镜像窗口来实现这些目标。该方法在各种光谱畸变情况下进行了测试,并成功地恢复了数据的均匀性。结论是,MSA PET成像可能具有相对不均匀的检测器响应,但稳定的检测器特性是必不可少的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Results in online data processing in the data acquisition system of the ALEPH TPC Practical evaluation of several cone beam orbits for SPECT Model based scatter correction in three dimensions (positron emission tomography) Macintosh software for simulating resolution and scatter effects in PET Testing fast ADC's at sample rates between 20 and 140 MSPS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1