{"title":"Analysis of Three-Phase Delta-Connected Converter for Compensation of Unsymmetrical Loads","authors":"Martin Bejvl, P. Šimek, V. Valouch, R. Hauptmann","doi":"10.1109/EPE51172.2020.9269256","DOIUrl":null,"url":null,"abstract":"The paper presents possibilities of compensation of general single-phase load connected to the three-phase grid. The compensation is to ensure a symmetrical and pure active load of the three-phase grid. It is documented that after the proposed compensation it is possible to draw symmetrical and pure active current from all phases. A set of multi-level voltage converters is considered as a compensation device. The paper presents a way of determining the reference currents for the converter in its two branches and proposes a method of controlling the converter so that the active power from the grid is equal to the active load of the load. This methodology is documented by the results of a series of simulations for static and dynamic modes of the system.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"252 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The paper presents possibilities of compensation of general single-phase load connected to the three-phase grid. The compensation is to ensure a symmetrical and pure active load of the three-phase grid. It is documented that after the proposed compensation it is possible to draw symmetrical and pure active current from all phases. A set of multi-level voltage converters is considered as a compensation device. The paper presents a way of determining the reference currents for the converter in its two branches and proposes a method of controlling the converter so that the active power from the grid is equal to the active load of the load. This methodology is documented by the results of a series of simulations for static and dynamic modes of the system.